SafetyNotes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
The hot and cold supplies must be of equal pres-
sures.
InstallationInstructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
TechnicalData
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
max. 65°C
Thermal disinfection:
70°C / 4 min
Safety against backflow
The product is exclusively designed for drinking water!
English
Maintenance
(see page 64)
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
• The mixer is equipped with check valves.
The check valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
Adjustment
(see page 62)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
SafetyFunction
(see page 62)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
Spareparts
(see page 66)
Do not use silicone containing acetic acid!
Symboldescription
Cleaning
see enclosed brochure
Operation
(see page 68)
6
Содержание Axor Urquiola
Страница 24: ...1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 80 C 65 C 70 C 4 64 DIN EN 1717 62 62 42 66 68 24...
Страница 25: ...68 0 3 MPa 67 68 MTC 42 C 65 C 180 180 60 25...
Страница 27: ...68 0 3 67 68 42 65 180 60 27...
Страница 43: ...68 0 3 MPa 67 68 42 C 65 C 180 180 60 43...
Страница 55: ...68 0 3 67 68 42 C 65 C 180 180 60 55...
Страница 58: ...68 0 3 67 68 42 65 180 180 60 58...
Страница 59: ...1 0 5 0 1 1 6 PSI 147 10 1 80 C 65 C 4 70 C 64 DIN EN 1717 DIN 1988 62 62 42 66 68 59...
Страница 60: ...60 1 2 mm X Montage 2 1 2 2 SW 4 mm 5 Nm 3 4 5 1 01800180 1 2 3...
Страница 61: ...61 Montage 3 4 S W 3 m m 2 N m 2 1 7 6 8 9 10 11 X 11 0 1 Nm...
Страница 62: ...62 Safety Function Justierung 2 1 3 1 1 2 S W 3 m m 2...
Страница 63: ...63 z B 42 C for example 42 C 2 1 1 2 3 4 5 6 7 8 S W 3 m m 2 N m 1 2...
Страница 64: ...64 Wartung 1 2 3 2 3 4 5 6 SW 24 mm SW 4 mm 1...
Страница 65: ...65 Wartung 2 1 8 9 10 11 12 SW 24 mm 15 Nm SW 4 mm 5 Nm 7...
Страница 67: ...67 Pr fzeichen P IX DVGW SVGW ACS WRAS ETA KIWA 11731000 P IX 18019 II BQ0587 X X X X DIN 4109 P IX 18019 II...
Страница 75: ...75...