0 2

A S S E M B L Y   (see page 04 )

EN

 

S A F E T Y   N O T E S

 

Gloves should be worn during installation to prevent 
crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 
and body cleaning purposes.

 

The hot and cold supplies must be of equal pressures.

I N S T A L L A T I O N   I N S T R U C T I O N S

⁄  Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 
surface damage will be honoured.

⁄  The pipes and the fixture must be installed, flushed and 

tested as per the applicable standards.

⁄  The plumbing codes applicable in the respective 

countries must be observed.

⁄  The drain valve must only be used as intended. It is not 

allowed to attach other objects to the drain valve, for 
example a semi-pedestal.

T E C H N I C A L   D A T A
Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 70°C 

Recommended hot water temp.: 

65°C 

Thermal disinfection: 

max. 70°C / 4 min

The product is exclusively designed for drinking water!

S Y M B O L   D E S C R I P T I O N

Do not use silicone containing acetic acid!

A D J U S T M E N T   (see page 06 )

To adjust the hot water limiter. Using a hot water 
limiter in combination with a continuous flow 
water heater is not recommended.
D I M E N S I O N S   (see page 08 )

F L O W   D I A G R A M   
(see page 08 )
S P A R E   P A R T S   (see page 10 )
S P E C I A L   A C C E S S O R I E S 
(order as an extra)

⁄  special tool #58085000 (see page 04 )

⁄  Installation putty (see page 05)

C L E A N I N G   (see page 07)

O P E R A T I O N   (see page 12 )

Hansgrohe recommends not to use as drinking water the 
first half liter of water drawn in the morning or after a 
prolonged period of non-use.

F A U L T

C A U S E

R E M E D Y

⁄  Insufficient water

⁄  Aerator calcified, dirty

⁄  Clean aerator, replace as necessary

⁄  Mixer stiff

⁄  Cartridge defective

⁄  Exchange cartridge

⁄  Mixer dripping

⁄  Cartridge defective

⁄  Exchange cartridge

⁄  Water escaping at the connection 

hose

⁄  Cartridge defective

⁄  Exchange cartridge

⁄  O-ring defective

⁄  Exchange O-ring

⁄  Water escaping at the connection 

hose

⁄  Connection hose defective

⁄  Exchange connection hose

⁄  O-ring defective

⁄  Exchange O-ring

⁄  Adapter for cartridge defective

⁄  Exchange adapteur pour cartouche

⁄  O ring of adapter for cartridge defec-

tive

⁄  Exchange O-ring

⁄  Hot water temperature too low

⁄  Hot water limiter incorrectly set

⁄  Set hot water limiter

Содержание Axor Citterio M 34120003

Страница 1: ...I N S T A L L A T I O N E N Instructions for use assembly instructions 02 D E Gebrauchsanleitung Montageanleitung 03 AXOR Citterio M 100 34031009 AXOR Citterio M 34120003 AXOR Citterio M 250 34103009 ...

Страница 2: ...P T I O N Do not use silicone containing acetic acid A D J U S T M E N T see page 06 To adjust the hot water limiter Using a hot water limiter in combination with a continuous flow water heater is not recommended D I M E N S I O N S see page 08 F L O W D I A G R A M see page 08 S P A R E P A R T S see page 10 S P E C I A L A C C E S S O R I E S order as an extra special tool 58085000 see page 04 I...

Страница 3: ...nzipiert S Y M B O L E R K L Ä R U N G Kein essigsäurehaltiges Silikon verwenden J U S T I E R U N G siehe Seite 06 Einstellen der Warmwasserbegrenzung In Verbindung mit Durchlauferhitzern ist eine Warmwassersperre nicht zu empfehlen M A S S E siehe Seite 08 D U R C H F L U S S D I A G R A M M siehe Seite 08 S E R V I C E T E I L E siehe Seite 10 S O N D E R Z U B E H Ö R nicht im Lieferumfang ent...

Страница 4: ...0 4 1 2 3 4 3 Nm 5 58085000 max 7 Nm 6 SW 10 mm SW 24 mm 4 Nm ...

Страница 5: ...0 5 50 Ncm 50 Ncm 11 7 9 8 10 11 12 58085000 max 7 Nm 9 11 13 15 14 2 min ...

Страница 6: ...60 C 10 C 0 3 MPa 6 7 8 4 5 3 1 2 SW 3 mm 3 x SW 3 mm 5 Nm 36 C 38 C 43 C 60 C 55 C 50 C 0 6 ...

Страница 7: ...mmendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation E N Cleaning recommendation Warranty Contact D E Reinigungsempfehlung Garantie Kontakt 3 2 1 ...

Страница 8: ... 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec AXOR Citterio M 34120003 AXOR Citterio M 34120003 94139007 51302000 ...

Страница 9: ...itterio M 250 34103009 AXOR Citterio M 34103009 34031009 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec ...

Страница 10: ...000 34093000 98865000 97685000 96762000 SW 3mm 98863000 97489000 900 mm 96923000 98866000 13961000 98398000 23x2 98987000 98749000 97548000 98398000 23x2 98146000 25x1 5 92527000 27x1 5 AXOR Citterio M 34120003 98864000 SW 27 mm ...

Страница 11: ...920000 34093000 98865000 95973000 98864000 SW 27 mm 98863000 97443000 470 mm 97489000 900 mm 98866000 13961000 98398000 23x2 98987000 98749000 97548000 98398000 23x2 98146000 25x1 5 92527000 27x1 5 AXOR Citterio M 34031009 34103009 ...

Страница 12: ...AXOR Hansgrohe SE Auestraße 5 9 77761 Schiltach Deutschland info axor design com axor design com 05 2020 9 04380 33 schließen close öffnen open warm hot kalt cold ...

Отзывы: