0 2
A S S E M B L Y (see page 04)
EN
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 09)
To adjust the hot water limiter. Using a hot water
limiter in combination with a continuous flow
water heater is not recommended.
M A I N T E N A N C E (see page 11)
The check valves must be checked regularly
according to EN 806-5 in accordance with
national or regional regulations (at least once a
year).
D I M E N S I O N S (see page 13)
F L O W D I A G R A M (see page 13)
S P A R E P A R T S (see page 14)
C L E A N I N G (see page 12)
O P E R A T I O N (see page 10)
⁄ Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or after
a prolonged period of non-use.
⁄ Do not rotate the spout further than 360º or damage to
the hose will result.
F A U L T
C A U S E
R E M E D Y
⁄ Insufficient water
⁄ Aerator calcified, dirty
⁄ Clean aerator, replace as necessary
⁄ Mixer stiff
⁄ Cartridge defective, calcified
⁄ Exchange cartridge
⁄ Mixer dripping
⁄ Cartridge defective
⁄ Exchange cartridge
⁄ Water escaping at the threaded base ⁄ connection hoses not completely
screwed into basic body
⁄ Tighten connection hoses by hand
⁄ O-ring at the connection hose defec-
tive.
⁄ Exchange O-ring
⁄ Hot water temperature too low
⁄ Hot water limiter incorrectly set
⁄ Set hot water limiter
Содержание AXOR Citterio 250
Страница 4: ...0 4 150 110 6a 6b SW 10 mm SW 24 mm 4 Nm max 35 mm max 60 mm 3 Nm 1b 2 3 4 5 1a...
Страница 5: ...0 5 150 24 x 15 75 45 45 75 1 0 5 1 0 5 6a...
Страница 6: ...0 6 6b 24 x 15 110 110 55 25 55 85 85 25...
Страница 7: ...0 7 80 7 8 10 11 12 CLICK 2 3 1 9...
Страница 8: ...0 8 1 Nm 2 min 13 14 15...
Страница 9: ...0 3 MPa 60 C 10 C 6 5 3 4 36 C 38 C 43 C 60 C 55 C 50 C 1 2 1 2 SW 3 mm 4 x 1 2 SW 3 mm 5 Nm 0 9...
Страница 10: ...1 0 1 2 close schlie en open ffnen open ffnen hot warm cold kalt...
Страница 11: ...11 2 1...
Страница 15: ...1 5...