0 6
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and⁄or
sensoric impairments must not use this product without
proper supervision. Persons under the influence of alco-
hol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective coun-
tries must be observed.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C ⁄ 4 min
Safety against backflow
The product is exclusively designed for drinking water!
EN
D I M E N S I O N S (see page 65)
M A I N T E N A N C E (see page 67)
The check valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once
a year). To guarantee the smooth running of the
thermostat, it is necessary from time to time to turn
the thermostat from total hot to total cold.
F L O W D I A G R A M
(see page 66)
Rate of flow by 0,3 MPa:
Tub outlet
Shower outlet
S A F E T Y F U N C T I O N (see page 63)
The desired maximum temperature for example
max. 42º C can be pre-set thanks to the safety
function.
Do not use silicone containing acetic acid!
S Y M B O L D E S C R I P T I O N
A D J U S T M E N T (see page 62)
After the installation, the output temperature of
the thermostat must be checked. A correction is
necessary if the temperature measured at the
output differs from the temperature set on the
thermostat.
S P A R E P A R T S
(see page 69)
XXX = Colors
000 = chrome plated
090 = chrome plated⁄gold plated
340 = Brushed Black Chrome
800 = stainless steel optic
820 = brushed nickel
830 = polished nickel
Содержание AXOR Carlton 17720 Series
Страница 60: ...6 0 SW 4 mm 5 Nm 2 3 1 Montage 1 2 1 2 2 4 3 5 6 1 2 mm X 11 X 01800180 ...
Страница 63: ...6 3 Safety Function z B 42 C for example 42 C 2 1 1 2 SW 3 mm 4 Nm 1a 1b 2 SW 2 mm SW 2 mm SW 3 mm 3 4 5 6 ...
Страница 64: ...6 4 Safety Function Bedienung 7 8a 8b SW 2 mm 4 Nm SW 2 mm 4 Nm 1 2 40 C ...
Страница 67: ...6 7 A 1 2 Wartung SW 4 mm 1 6 2 3 4 5 1a 2 3 4 1 1 2 3 4 1b SW 2 mm SW 2 mm S W 3 m m S W 3 m m 1 2 SW 24 mm A ...
Страница 79: ...7 9 ...