0 4
A S S E M B L Y (see page 31)
F A U L T
C A U S E
R E M E D Y
⁄ Insufficient water
⁄ Supply pressure inadequate
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Regulator filter dirty
⁄ Clean filter in front of the mixer and on the MTC-thermo
cartridge
⁄ Shower filter seal dirty
⁄ Clean filter seal between shower and hose
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Valve damaged (#96740000)
⁄ Replace valve (#96740000)
⁄ Spout temperature does not correspond with temperature
set
⁄ Thermostat has not been adjusted
⁄ Adjust thermostat
⁄ Hot water temperature too low
⁄ Increase hot water temperature to 42 ºC to 65 ºC
⁄ Temperature regulation not possible
⁄ thermo cartridge calcified
⁄ Exchange thermo cartridge
⁄ Instantaneous heater didn't work with thermostat
⁄ Filters are dirty
⁄ Clean the filter ⁄ exchange filter
⁄ check valve hasn't moved back
⁄ Exchange check valves
⁄ Flow limiter in handshower isn’t removed
⁄ Remove flow limiter
C L E A N I N G (see page 34) and enclosed brochure
S P A R E P A R T S
(see page 38)
XXX = Colors
000 = chrome plated
090 = chrome plated⁄gold plated
820 = brushed nickel
F L O W D I A G R A M (see page 37)
overhead shower
Hand shower
D I M E N S I O N S (see page 37)
O P E R A T I O N (see page 36)
To empty the overhead shower after use, hold it in a slightly inclined position.
M A I N T E N A N C E (see page 34)
⁄ The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with na-
tional or regional regulations (at least once a year).
⁄ To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
A D J U S T M E N T (see page 33)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
S A F E T Y F U N C T I O N (see page 33)
The desired maximum temperature for example max. 42º C can be pre-set
thanks to the safety function.
Do not use silicone containing acetic acid!
S Y M B O L D E S C R I P T I O N
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
The arm of the shower head is intended only to hold the shower head. Do not load
it down with other objects!
Children as well as adults with physical, mental and⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be altered
if required. In this case, pay attention to the fact that a change of installation height
will also change the minimum height, and that the altered mounting dimensions must
be taken into consideration.
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ The mesh washer must be insert to protect the overhead shower against incoming
dirt by pipework. Incoming dirt leads to defects or⁄and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
⁄ The product is not designed to be used with steam baths!
⁄ If required, the bottom part of the pipe between the fixture and the shower head
can be shortened with a fine-toothed saw.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,13 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
150±16mm
Connections G 1⁄2:
cold right - hot left
Thermal disinfection:
max. 70°C ⁄ 4 min
EN
Safety against backflow
The product is exclusively designed for drinking water!
T E S T C E R T I F I C A T E (see page 39)