4
English
Assembly
(see page 21)
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• During initial start-up and after servicing, air in the fittings can cause noise. After
switching the jet on and off about 15 times, the noise will stop.
• The flush water initially exhibits a milky cloudiness. This is caused by the
dispersed air and will clear after a short while.
• Check the correct position of the filter cartridge in the filter bowl by means of the
markings on wall holder and filter cartridge. Pay attention to the position of the
label when inserting the cartridge. It should face forward so that all the required
information is visible.
• Please enter the date of installation and the time of replacement into the
corresponding fields on the filter cartridge label.
Technical Data
Entnahmemenge gefiltertes Wasser:
1,3 l/min
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
see label on the filter cartridge
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
No drinking water
Adjustment
(see page 23)
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
Maintenance
(see page 24)
The check valves must be checked regularly according to EN 806-5 in accordance
with national or regional regulations (at least once a year).
Dimensions
(see page 25)
Flow diagram
(see page 25)
Spare parts
(see page 27)
XXX = Colors
000 = Chrome Plated
670 = Matt Black
800 = Stainless Steel Optic
Special accessories
(see page 26)
(order as an extra)
• extension #43333000
• Filter with activated carbon #76814000
• Filter with activated carbon and ion exchanger #76815000
• Filter with activated carbon and ion exchanger Pro #76827000
• Filter with activated carbon and mineralisation (Harmony) #76828000
• Filter with activated carbon and mineralisation (Life) #76829000
• Filter with activated carbon and mineralisation (Sport) #76830000
• Flow meter #76818000
Cleaning
(see page 24)
Filter replacement
(see page 26)
Replace the filter after 1/2 year of non-use and/or after 4 weeks without water
being released. Wear sterile disposable gloves when replacing the filter cartridges.
Bypass positon #76815000, #76827000
(see page 28)
To determine the carbonate hardness in local tap water, use an appropriate test kit.
If a test kit is not available, please ask your water utility.
Operation
(see page 23)
Hansgrohe recommends not to use as drinking water the first half liter of water
drawn in the morning or after a prolonged period of non-use.
Test certificate
(see page 24)
+
Fault
Cause
Remedy
Insufficient water
- Aerator calcified, dirty
- Clean aerator, replace as necessary
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping at the threaded base
- connection hoses not completely screwed into basic
body
- Tighten connection hoses by hand
- O-ring at the connection hose defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Low flow with Select valve after valve replacement
- Improper Select valve installed
- Replace Select valve (#98463000)
Select button stiff
- Select button soiled
- Clean Select button and grease 23x1,5 O-ring
(see page 27)