Hanna Instruments Inc., 584 Park East Drive, Woonsocket, RI 02895 USA
www.hannainst.com
Please scan the QR code or follow the link
to download the user manual.
https://manuals.hannainst.com/HI6321
Hanna
®
is committed to developing and deploying digital
solutions with a positive impact on the environment and climate.
Package contents
•
HI6321
•
HI7631233
four-ring conductivity probe
• 1413 μS/cm conductivity standard solution (4 sachets)
• 5000 μS/cm conductivity standard solution (2 sachets)
• 12880 μS/cm conductivity standard solution (2 sachets)
• Electrode rinse solution (2 sachets)
20 mL
For laboratory and industrial use only.
Store at room temperature.
For laboratory and industrial use only.
Store at room temperature.
±5 μS/cm @ 25 °C (77 °F)
Traceable to NIST Standard reference material
±5 μS/cm @ 25 °C (77 °F)
Traceable to NIST Standard reference material
Conductivity Standard
Conductivity Standard
1413
μS/cm
1413
μS/cm
HI70031
HI70031
20 mL
For laboratory and industrial use only.
Store at room temperature.
For laboratory and industrial use only.
Store at room temperature.
±20 μS/cm @ 25 °C (77 °F)
Traceable to NIST Standard reference material
±20 μS/cm @ 25 °C (77 °F)
Traceable to NIST Standard reference material
Conductivity Standard
Conductivity Standard
5000
μS/cm
5000
μS/cm
HI70039
HI70039
20 mL
For laboratory and industrial use only.
Store at room temperature.
For laboratory and industrial use only.
Store at room temperature.
±50 μS/cm @ 25 °C (77 °F)
Traceable to NIST Standard reference material
±50 μS/cm @ 25 °C (77 °F)
Traceable to NIST Standard reference material
Conductivity Standard
Conductivity Standard
12880
μS/cm
12880
μS/cm
HI70030
HI70030
Electrode
Rinse
Solution
Electrode
Rinse
Solution
HI70000
HI70000
~20 mL @ 25 °C / 77 °F
• Electrode arm with base plate and screws (mounting)
• 24 VDC power adapter and USB-C to USB-A cable
• Probe quality certificate, instrument quality certificate,
quick reference guide
HI6321
Advanced
Conductivity
Benchtop Meter
Quick Reference Guide
Dear Customer, thank you for choosing Hanna Instruments.
Getting started
Identify the base plate (1) – to be attached to the
L
or the
R
side –
and mounting screw (2) and proceed as illustrated here.
R
L
2
1
With the arm holder (3) in position and the probe (4) plugged in,
connect the power cable (5) and plug into the mains. Press the
ON/OFF button (6) to start.
Remove the transparent film that protects the capacitive touchscreen
prior to operating the meter.
H
HII632211 Conductivit
y
EC
Ethernet
Extension
USB-A
USB-C
ON/OFF
Power
24Vdc
5
6
4
3
Operating language & Access to support
• At first power on default operating language is English. Browse
the language window and select operating language from list of
supported options.
• To access support, tap
and select
.
On first access the benchtop’s name is used as default user name
and no password is required.
Device handling & Safety precautions
• Transport the unit with all cables removed.
• Do not puncture the capacitive touchscreen.
• Do not insert objects into the ports, spaces around keys other
than the intended cable, USB drive.