Hanna Instruments HI 95734C Скачать руководство пользователя страница 4

4

The 

HI 95734 

is an auto diagnostic portable microprocessor meter that benefits from Hanna’s

years of experience as a manufacturer of analytical instruments. It has the advanced optical system
based on a special tungsten lamp and a narrow band interference filter that allows most accurate
and repeatable readings. All instruments are factory calibrated and the electronic and optical
design minimizes the need of frequent calibration.
With the powerful CAL CHECK™ 

validation

 function you are able to validate good performance of

your instrument at any time. The validation procedure is extremely user friendly. Just use the
exclusive Hanna ready-made, NIST traceable standards to verify the performance of the instrument
and recalibrate if necessary.
All instruments are splash waterproof and the lamp and filter units are protected from dust or dirt by
a transparent cup. This makes the instruments fulfill field applications. Display codes aid the user in
routine operation. The meter has an auto-shut off feature that will turn off the instrument  after 10
minutes of non use or after 1 hour if left in the 

calibration mode

.

The meter uses an exclusive positive-locking system to ensure that the cuvet is in the same position

every time it is placed into the measurement cell. It is designed to fit a cuvet with a larger neck
making it easier to add both sample and reagents. The cuvet is made from special optical glass to
obtain best results.
The 

HI 95734

 meter measures the free and total chlorine (Cl

2

) content in water samples in the

0.00 to 10.00 mg/L (ppm) range. The method is an adaption of the USEPA METHOD 330.5 for
wastewater, and Standard Method 4500-Cl G for drinking water.
The reagents are in

 

powder and liquid form and are supplied in packets and bottles. The amount of

reagent is precisely dosed to ensure the maximum repeatability.

degree Celsius
US Environmental Protection Agency
degree Fahrenheit
High Range
milligrams per liter. mg/L is equivalent to ppm (part per million)
milliliter

°C

:

EPA

:

°F

:

HR

:

mg/L

:

mL

:

GENERAL DESCRIPTION

ABBREVIATIONS

21

Recommendations for Users

Before using these products, make sure that they are entirely suitable for your specific application and for the
environment in which they are used.
Operation of these instruments may cause  unacceptable interferences to other electronic equipments, this requiring the
operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance.
To avoid damages or burns, do not put the instrument in microwave ovens. For yours and the instrument safety do not
use or store the instrument in  hazardous environments.

Battery replacement must only take place in a non-
hazardous area.
Simply slide off the battery cover on the back of the
meter. Detach the battery from the terminals and attach

a fresh 9V battery while paying attention to the correct
polarity. Insert the battery and replace the cover.

9V

SLIDE

OFF

BATTERY REPLACEMENT

     DECLARATION OF CONFORMITY

Содержание HI 95734C

Страница 1: ...Instruction Manual HI 95734C Free Total Chlorine High Range ISM w w w h a n n a i n s t c o m This Instrument is in Compliance with the CE Directives 24 MAN95734R3 07 06 w w w h a n n a i n s t c o m...

Страница 2: ...RE 18 ACCESSORIES 20 BATTERY REPLACEMENT 21 DECLARATION OF CONFORMITY 21 WARRANTY 22 HANNA LITERATURE 22 USER NOTES 23 Dear Customer Thank you for choosing a Hanna product This manual will provide you...

Страница 3: ...ooks and leaflets contact your dealer or the Hanna Customer Service Center nearest to you To find the Hanna Office in your vicinity check our home page at www hannainst com HI 95734 is warranted for t...

Страница 4: ...glass to obtain best results The HI 95734 meter measures the free and total chlorine Cl2 content in water samples in the 0 00 to 10 00 mg L ppm range The method is an adaption of the USEPA METHOD 330...

Страница 5: ...result to the true value Although good precision suggests good accuracy precise results can be inaccurate The figure explains these definitions In a laboratory using a standard solution of 3 00 mg L...

Страница 6: ...of Hanna s HI 95 series colorimeters is based on special subminiature tungsten lamps and narrow band interference filters to guarantee both high performance and reliable results Block diagram optical...

Страница 7: ...ot to touch the cuvet walls with hands Furthermore in order to maintain the same conditions during the zeroing and the measuring phases it is necessary to close the cuvet to prevent any contamination...

Страница 8: ...holder and ensure that the notch on the cap is positioned securely into the groove Press ZERO and SIP will blink on the display After a few seconds the display will show 0 0 The meter is now zeroed a...

Страница 9: ...3734C 0 reagent to the cuvet For both free and total chlorine add the content of one packet of HI 93701 0 Free Chlorine reagent Replace the cap and shake gently for 20 seconds or 2 minutes in case of...

Страница 10: ...ervice Center CALIBRATION MODE MESSAGES The date of the last calibration appears on the LCD each time the calibration mode is entered If calibration is performed for the first time F CAL appears This...

Страница 11: ...surement A flashing value of the maximum concentration indicates an over range condition The concentration of the sample is beyond the programmed range dilute the sample and re run the test A flashing...

Страница 12: ...lint free cloth prior to insertion GENERAL TIPS FOR AN ACCURATE MEASUREMENT a b c 13 Proper use of the dropper a to get good reproducible results tap the dropper on the table for several times and wip...

Отзывы: