Hanna Instruments HI 95734C Скачать руководство пользователя страница 2

2

All rights are reserved. Reproduction in whole or in part is prohibited without the written consent
of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895 , USA.

PRELIMINARY EXAMINATION ................................................................................................ 3
GENERAL DESCRIPTION......................................................................................................... 4
ABBREVIATIONS................................................................................................................... 4

SPECIFICATIONS .................................................................................................................. 5
PRECISION AND ACCURACY ................................................................................................... 5
PRINCIPLE OF OPERATION .................................................................................................... 6
FUNCTIONAL DESCRIPTION ................................................................................................... 8
GUIDE TO DISPLAY CODES .................................................................................................... 9
GENERAL TIPS FOR AN ACCURATE MEASUREMENT .................................................................12
OPERATIONAL GUIDE ...........................................................................................................14
MEASUREMENT PROCEDURE ................................................................................................15
VALIDATION PROCEDURE .....................................................................................................17

CALIBRATION PROCEDURE ...................................................................................................18
ACCESSORIES .....................................................................................................................20
BATTERY REPLACEMENT .......................................................................................................21
      DECLARATION OF CONFORMITY .....................................................................................21
WARRANTY .........................................................................................................................22
HANNA LITERATURE.............................................................................................................22
USER NOTES.......................................................................................................................23

Dear Customer,
Thank you for choosing a Hanna product. This manual will provide you with the necessary
information for the correct use of the instrument. Please read it carefully before using the meter. If

you need additional technical information, do not hesitate to e-mail us at [email protected].
This instrument is in compliance with   directives.

TABLE OF CONTENTS

23

 Date

 Validation Value

 (mg/L)

 Calibration

   yes         not

 Parameter Code

 Passed

   yes         not

USER NOTES

HANNA instruments®

 reserves the right to modify the design, construction and appearance of its

products without advance notice.

Содержание HI 95734C

Страница 1: ...Instruction Manual HI 95734C Free Total Chlorine High Range ISM w w w h a n n a i n s t c o m This Instrument is in Compliance with the CE Directives 24 MAN95734R3 07 06 w w w h a n n a i n s t c o m...

Страница 2: ...RE 18 ACCESSORIES 20 BATTERY REPLACEMENT 21 DECLARATION OF CONFORMITY 21 WARRANTY 22 HANNA LITERATURE 22 USER NOTES 23 Dear Customer Thank you for choosing a Hanna product This manual will provide you...

Страница 3: ...ooks and leaflets contact your dealer or the Hanna Customer Service Center nearest to you To find the Hanna Office in your vicinity check our home page at www hannainst com HI 95734 is warranted for t...

Страница 4: ...glass to obtain best results The HI 95734 meter measures the free and total chlorine Cl2 content in water samples in the 0 00 to 10 00 mg L ppm range The method is an adaption of the USEPA METHOD 330...

Страница 5: ...result to the true value Although good precision suggests good accuracy precise results can be inaccurate The figure explains these definitions In a laboratory using a standard solution of 3 00 mg L...

Страница 6: ...of Hanna s HI 95 series colorimeters is based on special subminiature tungsten lamps and narrow band interference filters to guarantee both high performance and reliable results Block diagram optical...

Страница 7: ...ot to touch the cuvet walls with hands Furthermore in order to maintain the same conditions during the zeroing and the measuring phases it is necessary to close the cuvet to prevent any contamination...

Страница 8: ...holder and ensure that the notch on the cap is positioned securely into the groove Press ZERO and SIP will blink on the display After a few seconds the display will show 0 0 The meter is now zeroed a...

Страница 9: ...3734C 0 reagent to the cuvet For both free and total chlorine add the content of one packet of HI 93701 0 Free Chlorine reagent Replace the cap and shake gently for 20 seconds or 2 minutes in case of...

Страница 10: ...ervice Center CALIBRATION MODE MESSAGES The date of the last calibration appears on the LCD each time the calibration mode is entered If calibration is performed for the first time F CAL appears This...

Страница 11: ...surement A flashing value of the maximum concentration indicates an over range condition The concentration of the sample is beyond the programmed range dilute the sample and re run the test A flashing...

Страница 12: ...lint free cloth prior to insertion GENERAL TIPS FOR AN ACCURATE MEASUREMENT a b c 13 Proper use of the dropper a to get good reproducible results tap the dropper on the table for several times and wip...