background image

Hanna Instruments reserves the right to modify the design, construction or appearance of its products without advance notice.

CERTIFICATION

All Hanna Instruments conform to the 

CE European Directives.

Disposal of Electrical and Electronic Equipment. 

The product should not be treated as household waste. 

Instead, hand it over to the appropriate collection point for the recycling of electrical and electronic equipment, 

which will conserve natural resources.

Disposal of waste batteries.

 This product contains batteries, do not dispose of them with other household 

waste. Hand them over to the appropriate collection point for recycling. Ensuring proper product and battery 

disposal prevents potential negative consequences for the environment and human health. For more information, 

contact your city, your local household waste disposal service, or the place of purchase.

Regulatory Notices for the stand-alone, Bluetooth, low-energy module.

United States (FCC)

 FCC ID: 2AA9B04. This device complies with FCC Rules, Part 15 Subpart C “Intentional Radiators” 

and Subpart B, Chapter §15.105. This equipment has been tested and found to comply with the limits for a Class A 

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 

harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, 

and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may 

cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause 

harmful interference in which case, users are required to correct the interference at their own expense.

Canada (ISED)

 IC: 12208A-04. This device complies with Industry Canada license exempt RSS standard(s). Operation 

is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any 

interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme 

aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux 

conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout 

brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

Australia / New Zealand (RCM)

 BMD-300 complies with the AS/NZS 4268:2017.

Japan (MIC) 

South Korea (KCC) 

R-CRM-Rgd-BMD-300

Brazil (ANATEL)

: Contains ANATEL approved module # 00820-21-05903.

Mexico (IFETEL)

: Este equipo contiene el módulo con IFT #: NYCE/CT/0146/17/TS.

Содержание HALO 2 HI9810352

Страница 1: ...INSTRUCTION MANUAL HI9810352 Wireless pH Tester for Sushi with built in specialized electrode Foodcare ...

Страница 2: ...g a Hanna Instruments product Please read this instruction manual carefully before using this instrument This manual will provide you with the necessary information for correct use of this instrument as well as a precise idea of its versatility If you need additional technical information do not hesitate to e mail us at tech hannainst com or view our contact list at www hannainst com Dear Customer...

Страница 3: ...Mode 6 Bluetooth Pairing 7 Date Time 7 7 Bluetooth 7 8 Hanna Lab Application 7 Tag a Measurement 7 9 Calibration 7 Preparation Guidelines 7 Procedure 7 Stand Alone Tester Up to Three Point Calibration 8 With Hanna Lab App Up to Four Point Calibration 8 10 Sushi Rice Measurement 8 Preparation 8 Direct Measurement 9 Measurement of Rice Slurries 9 11 Care Maintenance 9 Storage 9 12 Warning Error Mess...

Страница 4: ...ion pH 0 01 or 0 1 pH mV 0 1 or 1 mV Temperature 0 1 C 0 1 F Accuracy pH 0 05 pH Temperature 0 5 C 0 9 F Calibration Up to three points or four points Automatic buffer recognition with Standard buffers Hanna pH 1 68 4 01 7 01 10 01 or NIST pH 1 68 4 01 6 86 9 18 Temperature compensation Automatic ATC or Manual MTC Electrode Body material Titanium Glass Low Temperature LT Junction Open Reference ce...

Страница 5: ... titanium works as an electronic shield protecting against interferences from electrical noise or humidity The flat glass tip provides optimal surface contact for sushi rice pH measurements and for surfaces that cannot be penetrated The open junction reference resists clogging due to the hard gel surface viscolene that is used for the reference cell When the junction becomes coated with starch fro...

Страница 6: ...ed battery type Dispose of old battery in accordance with local regulations 6 SETUP The Setup button is located inside the battery compartment After Setup configuration replace the cover Setup Menu Navigation Press the Setup button to enter Setup mode and navigate menu items To exit Setup mode press the Setup button after SEt TIME option is displayed Press the ON OFF button to configure menu item ...

Страница 7: ... in discoverable mode it will appear in the list of Available Devices Withintheapplication tap Connect topairthetesterwiththedevice Allreadingsaretransmitteddirectlytotheapplication Tag a Measurement Once connected to the application the ON OFF button can be pressed to tag the current reading Press the ON OFF button from measurement mode The display shows SEt TAG followed by TAG The reading on the...

Страница 8: ...buffer rinse beaker then in the second calibration buffer Wait until the measurement is stored and the stability indicator disappears 7 Place the tip of the electrode in the third buffer rinse beaker then in the third calibration buffer Wait until the measurement is stored and the stability indicator disappears 8 After the third point has been stored CAL SAVE is displayed briefly and the tester wi...

Страница 9: ...on level Fresh buffers should be used for each calibration Once the sachets are opened the buffer value can change over time If the electrode is slow or sluggish soak it in cleaning solution for 20 minutes Rinse with water and hydrate the electrode in storage solution for a minimum of 30 minutes before calibrating If measurements are taken successively rinse the probe thoroughly in distilled or de...

Страница 10: ...pper RECOMMENDATIONS FOR USERS Before using this product make sure it is entirely suitable for your specific application and for the environment in which it is used Any variation introduced by the user to the supplied equipment may degrade the tester s performance For your and the tester s safety do not use or store it in hazardous environments WARRANTY HI9810352 is warranted for a period of one y...

Страница 11: ...ovide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interferenc...

Страница 12: ...World Headquarters Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA www hannainst com MAN9810352 Printed in ROMANIA ...

Отзывы: