Hanna Instruments Foodcare HI 93501 Скачать руководство пользователя страница 1

1

Instruction Manual

HI93501
HI935001
HI935007
HI935004
HI935008

Portable Microprocessor

Thermometers

w w w . h a n n a i n s t . c o m

Содержание Foodcare HI 93501

Страница 1: ...1 Instruction Manual HI93501 HI935001 HI935007 HI935004 HI935008 Portable Microprocessor Thermometers w w w h a n n a i n s t c o m...

Страница 2: ...If under warranty report the model number date of purchase serial number and the nature of the problem If the repair is not covered by the warranty you will be notified of the charges incurred If the...

Страница 3: ...008 are pro fessional rugged and waterproof thermometers designed to be used on a daily basis in industrial kitchens and catering They provide excellent accuracy and can operate with a wide range of i...

Страница 4: ...off capability Waterproof casing Range 50 0 to 150 0 C 58 0 to 302 0 F Resolution 0 1 C 0 1 F Accuracy 0 4 C 0 7 F excluding probe error Battery 3 x 1 5V AAA approx 5000 hours of continuous use Auto...

Страница 5: ...nge 50 0 to 199 9 C 58 0 to 399 9 F 200 to 1350 C 400 to 2462 F Resolution 0 1 C up to 199 9 C 1 C outside 0 1 F up to 399 9 F 1 F outside Accuracy 0 2 full scale excluding probe error Battery 3 x 1 5...

Страница 6: ...life indication low battery detection Auto off capability Waterproof casing Range 50 0 to 400 0 C 58 0 to 752 0 F Resolution 0 1 C 0 1 F Accuracy 0 2 full scale excluding probe error Battery 3 x 1 5V...

Страница 7: ...e list of Hanna probes Note HI935007 and HI935008 has a fixed probe To switch the meter ON press the ON OFF button on the front of the meter If it does not turn on make sure that the batteries are pro...

Страница 8: ...and NO PROBE message is displayed see WARNING MESSAGES section If the reading is slightly beyond the measuring range the meter flashes the closest full scale value To switch the meter OFF press the O...

Страница 9: ...user to check the instrument calibration status If the meter is calibrated the display will stabilize and show 0 0 C 0 3 C in a few seconds WARNING MESSAGES NO PROBE message If the probe is not conne...

Страница 10: ...more than 0 3 C then a Err message is dispayed Contact your dealer or your nearest Hanna Service Center for recalibration DAMAGED PROBE message When the readings are very far from the reading range th...

Страница 11: ...ed inside the battery compartment Use the ON OFF button to switch between C or F Long press ON OFF button once to save and continue to auto off settings Use the ON OFF button to cycle through the foll...

Страница 12: ...ately replace the batteries with new ones Battery replacement must only take place in a non hazardous area The batteries are accessed by opening the battery compartment cap on the back of the instrume...

Страница 13: ...er without requiring recalibration Hanna probes are also available in different handle colors to avoid cross contamination during testing Note To clean the meters do not use aggressive detergents It i...

Страница 14: ...instruments in residential areas could cause unacceptable interferences to radio and TV equipment requiring the operator to follow all necessary steps to correct interferences Any variation introduce...

Страница 15: ...15...

Страница 16: ...anna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA Technical Support for Customers Tel 800 426 6287 Fax 401 765 7575 E mail tech hannainst com www hannainst com...

Отзывы: