51
5.5 Emergency plan
5.5.1 Severe abnormalities:
During use, users should be familiar with safety
precautions
and
should
not
carry
out
inappropriate operations to avoid improper use of
the battery (e.g., overcharge, over-discharge,
short circuit, extrusion, puncture, overheating and
high current discharge, etc.). In the charging and
operation process, the power battery system may
develop abnormalities: the temperature of
battery system or parts rises sharply; or abnormal
smell or smoke from the battery system.
5.6.2 Emergency plan:
(
1
)
All personnel at site should quickly leave the
forklift truck and call the fire station.
(
2
)
Carry out the following operations, if
possible, provided that personal safety can be
guaranteed:
a. If there is any smoke or burning in the external
wire, use a carbon dioxide or dry powder fire
extinguisher for fire-fighting.
b. If there is any smoke from the battery, use a
high-pressure water gun for fire-fighting at a
distance.
c. If the user inadvertently inhales smoke, please
leave the area and seek medical attention as soon
as possible.
Contact the forklift truck dealer for professional
advice.
Содержание XE Series
Страница 62: ...58 F11 Other faults F12 Abnormal current F13 Abnormal voltage...
Страница 73: ...69...