74
overheating, large current discharge, etc.) During charging and use, the battery system may appear
the following anomalies:
a
.
Sharp rise in battery system or local temperature.
b. There is an abnormal odor anywhere in the battery system.
c. Any part of the battery system smokes and catches fire.
2. Emergency measures in case of smoke or fire in the battery system during use, if smoke or
open fire occurs in the battery system during use, it shall be handled in the following order:
a. Park and power off.
b. The personnel quickly evacuated the vehicle and called the police according to the scene
situation.
c. Use water-based fire extinguishers to put out smoke or fire parts under the condition of
ensuring personnel safety
d. Notify our company personnel as soon as possible.