Hamworthy Heating Powerstock ST300 Скачать руководство пользователя страница 1

 

HAMWORTHY HEATING LTD 

 

 

POWERSTOCK 

 

500001177/I 

 

 

Powerstock Storage Tank 

 
 

Models ST300, ST500, ST750 

& ST1000 

 

 

INSTALLATION, COMMISSIONING AND 

SERVICING INSTRUCTIONS

 

 

 

THE POWERSTOCK STORAGE TANK IS INTENDED FOR USE AS A  

COMMERCIAL APPLIANCE.  

 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

PUBLICATION NO. 500001177 
ISSUE 'i’ 
SEPT. 15

 

Содержание Powerstock ST300

Страница 1: ...0001177 I Powerstock Storage Tank Models ST300 ST500 ST750 ST1000 INSTALLATION COMMISSIONING AND SERVICING INSTRUCTIONS THE POWERSTOCK STORAGE TANK IS INTENDED FOR USE AS A COMMERCIAL APPLIANCE PUBLICATION NO 500001177 ISSUE i SEPT 15 i ...

Страница 2: ...rawing Showing Mounting Location On ST500 Of Unvented Optional Kits 11 2 6 Drawing Showing Mounting Location On ST750 Of Unvented Optional Kits 12 2 7 Drawing Showing Mounting Location On ST1000 Of Unvented Optional Kits 13 5 1 Hot Water Applications Vented Systems 14 5 2 Hot Water Applications Unvented Systems 14 5 4 Hot Water Applications Plate Heat Exchanger 15 5 5 Hot Water Applications Solar ...

Страница 3: ...for the storage tanks is shown in Figure No 1 2 below Overall layout and dimensional data is shown in Figures 2 1 2 2 2 3 3 0 GENERAL REQUIREMENTS The installation of the storage tank must be in accordance with the relevant requirements of the Building Regulations Building Standards Scotland Regulations IEE Regulations Fire regulations and Water Supply Water Fittings regulations 3 1 RELATED DOCUME...

Страница 4: ...led advice on water circuit installation Insulation Jackets For ST750 ST100 must be fitted prior to pipe connection All circulation pipework must be lagged to prevent heat loss and possible freezing especially where pipes run through roof spaces and ventilated cavities F E tanks situated in areas that may be exposed to freezing conditions should also be insulated Drain valves must be located in ac...

Страница 5: ... low incoming water mains pressures Refer to Figure No 7 3 Cold Water Supply Valve Train For comprehensive recommendations on the design installation and testing of water supply services attention is drawn to the appropriate sections of BS 6700 The maximum hot working head of the Powerstock Storage Tank is 10 bar g 102 metres Dead legs to water draw off points should be as short as possible and in...

Страница 6: ... the hole for the neon in the self adhesive fascia label Refer to Figure No 7 5 Earth tag assembly Clean and abrade the outer surface of the cold water feed stub pipe at the base of the vessel to obtain a suitable earthing continuity point Select the jubilee clip and undo the screw until the clamping band can be opened out Note this action may not need to be carried out if site pipework has not ye...

Страница 7: ...is should be checked without water flowing through the tank thus keeping the time required for checking this operation to a minimum 9 0 SERVICING AND SPARES 9 1 The storage tank should be regularly checked for correct operation The sacrificial anode must be inspected at least once every 6 months for loss of material Spares are available on request refer to Hamworthy Heating for supply details IMPO...

Страница 8: ...MBLY FOLLOWING COMPLETE SER VICING OF THE STORAGE TANK Close the storage tank drain cock and remove the hose connection Open the cold feed hot flow and circulation isolation valves and allow the system to fill with water Check to ensure that there are no leaks from the in spection door sealing gasket the magnesium anode sealing washers and the drain cock Replace the insulation disc over the inspec...

Страница 9: ... 1 2 R1 1 2 R2 R2 M 16 16 40 40 N Circulation Control Panel Pocket Assembly R3 4 R3 4 R1 1 4 R1 1 4 O Sensor Pocket Connection R1 2 R1 2 P Sensor Pocket R1 2 R1 2 R1 2 R1 2 Q Cold Water Inlet Connection R1 R1 R2 R2 Q Secondary Cold Water Inlet Connection R1 1 2 R1 1 2 S 90 55 101 100 T 272 238 292 300 U 947 955 V 1180 1265 1147 1155 W 1546 1673 1642 1650 X 1908 1911 Y R1 R1 R1 1 4 R1 1 4 Z R1 1 4 ...

Страница 10: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I 8 Figure 2 2 General Arrangement Drawing Of ST300 ST500 ...

Страница 11: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I 9 Figure 2 3 General Arrangement Drawing Of ST750 ST1000 ...

Страница 12: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I 10 Figure 2 4 General Arrangement Showing Mounting Location Of Kits On ST300 ...

Страница 13: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I 11 Figure 2 5 General Arrangement Showing Mounting Location Of Kits On ST500 ...

Страница 14: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I 12 Figure 2 6 General Arrangement Showing Mounting Location Of Kits On ST750 ...

Страница 15: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I 13 Figure 2 7 General Arrangement Showing Mounting Location Of Kits On ST1000 ...

Страница 16: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I 14 Figure 5 1 Hot Water Applications Vented system Figure 5 2 Hot Water Applications Un Vented system ...

Страница 17: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I 15 Figure 5 4 Hot water Applications Plate Heat Exchanger ...

Страница 18: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I Figure 5 5 Hot water Applications Solar Preheating Example 1 Figure 5 6 Hot water Applications Solar Preheating Example 2 16 ...

Страница 19: ...c wiring diagram of the control box Figure 6 1 Storage Tank Control Box Fascia Control Thermostat Temperature Adjustment Dial Fuse Holder Safety Limit Thermostat Reset Button To Operate Remove Dust Cap Powered Anode Indication Light Anode Fitted As Optional Extra 17 ...

Страница 20: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I Figure 6 3 Wiring Schematics For Various Control Systems 18 ...

Страница 21: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I 19 Figure 6 4 Wiring Schematic For Immersion Heater Control ...

Страница 22: ...re 7 2 Clearances Required Around Product Figure 6 5 Table Of Minimum Contactor Current When Immersion Heaters Are Wired For Single 3 Phase Supply IMMERSION HEAT ER RATING kW HHL PART NUMBER SINGLE PHASE 3 PHASE 4 533901393 16 7 5 6 9 533901489 37 5 12 5 MINIMUM CONTACTOR CURRENT A 20 ...

Страница 23: ...required 741617250 1 off 741617250 1 off Expansion vessel Burstock range HHL Part No 25 litre x 2 563605641 60 litre 532712085 80 litre 532712086 100 litre 532712087 Secondary hot water side Pressure temperature relief valve set to 7 bar and 90 C 5 0 HHL PART No 531905004 Figure No 7 3 Cold Water Supply Valve Train NOTE ON PS750 AND PS1000 MODELS 1 TO 1 NIPPLE AND 1 SOCKET SUPPLIED TO BE USED TO I...

Страница 24: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I 22 Figure 7 4 Control box layout Mounting ...

Страница 25: ...HAMWORTHY HEATING LTD POWERSTOCK 500001177 I 23 Figure 7 5 Earth tag assembly Figure 9 1 Clean out door flange ...

Страница 26: ... 531911002 531911002 531911002 531911002 5 Pump adaptor 2 530905047 530905047 530905047 530905047 6 Pump Biral WX13 1 1154050150 1154050150 1154050150 1154050150 7 Elbow 1 532403011 532403011 532403011 532403011 8 Coupling 1 530505002 530505002 530505002 530505002 9 Check valve 1 531911003 531911003 531911003 531911003 10 Adaptor 1 741614291 741614291 741614291 741614291 11 Reducing Bush 2 7416273...

Отзывы: