background image

Installation manual Blue 12, 16, 21 & HE

EN 

V4.5

Blue

Содержание Blue 12

Страница 1: ...Installation manual Blue 12 16 21 HE EN V4 5 Blue...

Страница 2: ...production of all or part of this document is strictly prohibited except with the written permission of Hamwells Nederland B V The contents of this document are subject to change without notice The il...

Страница 3: ...ymbols 4 Warranty 5 Dimensions Blue basic 6 1 Installation Blue base 7 Installation instructions 8 Parts checklist 8 Parts Blue base 9 2 Installation options glass panel thermostat shower set 17 Parts...

Страница 4: ...ocal safety regulations These are persons who are technically skilled through education or training and who are familiar with the possible dangers and risks They are also familiar with local regulatio...

Страница 5: ...r purposes other than twater line described in this manual Incorrect assembly or alterations by the customer or third parties This also includes the use of non original replacement parts Incompetence...

Страница 6: ...210 cm 35 cm 38 cm 37 5 cm 15 cm 55 cm Blue HE Blue 21 Blue 16 Blue 12 Front view Back view Side view Including WWHR pipe of desired length Dimensions Blue basic Dimensions WWHR pipes 12 16 21 HE Powe...

Страница 7: ...1 Installation Blue base...

Страница 8: ...speci c to the Blue HE are included separately Tools such as drills screwdrivers mounting kit and wrenches are not included Installation instructions The parts of the Blue base are delivered complete...

Страница 9: ...water 1x water line 50 cm cold tap water 2x 3x 5x 1x Blue basic pre assembled WWHR Waste Water Heat Recovery frame WWHR pipe 12 16 21 HE Pump Power supply with cable without plug Water line 100 cm WW...

Страница 10: ...1 Temporarily hang the installation frame on the wall using two screws 90 cm 130 cm 2 Level the installation frame and mark the mounting holes Subsequently drill the holes and screw the frame in plac...

Страница 11: ...ion manual Blue V4 5 11 3 Connect the cold water supply Connect the cold water supply to the WWHR inlet using a exible water line Cold water connection of the Blue HE Make sure that the water line has...

Страница 12: ...lue V4 5 12 4 Connect the drain set to the WWHR pipe s Blue HE Blue HE 5 Connect the drain set to the sewer system Use the proper drain pipes and gaskets to connect the drains The WWHR has drain pipes...

Страница 13: ...nd level the sensor unit 7 Connect the supplied bend 32 mm to the back of the sensor unit and connect it to your drain We do not recommend pouring concrete around the sensor unit Use PVC adhesive afte...

Страница 14: ...lation manual Blue V4 5 14 7 Connect a siphon 40 mm to the sensor unit Shower drain Finished oor Over ow Make sure that the overflow is lower than the shower drain Side view Front view Shower drain Ov...

Страница 15: ...manual Blue V4 5 15 8 Connect the water line to the sensor unit Make sure that the water line has a gasket 9 Perform the drain test By pouring water into the siphon you test whether all drain parts ar...

Страница 16: ...anual Blue V4 5 16 10 Connect the wiring harness to the sensor unit Only connect the main power after everything else is connected 11 Check if the Blue is working properly See chapter 3 Calibration an...

Страница 17: ...2 Installation options glass panel thermostat shower set...

Страница 18: ...supplied connection water lines for the supplied thermostatic tap and shower set If you opt for a different type of thermostatic tap or shower set you must purchase suitable connection water lines Ma...

Страница 19: ...ower 1x hand shower set 1x water line 150 cm main shower to the thermostatic tap 1x water line 80 cm thermostatic tap to the hand shower 1x set of control buttons 1x thermostatic tap 1x water line 50...

Страница 20: ...nstallation manual Blue V4 5 20 1 Mount the frame of the secondary wall There are various options such a metal stud or wooden framework This varies by location Frame and retaining wall are not include...

Страница 21: ...cluded and connect the water water lines from the hand and main shower head The water line of the hand shower can be connected to either the left or right side This is connected to the thermostatic ta...

Страница 22: ...uded With the shower set option you must also mark and cut out drill the holes for the connections Hand shower and main shower head can be placed at the desired height Dimensions frame Dimensions hole...

Страница 23: ...Installation manual Blue V4 5 23 4 Place the waterproof wall 5 Tile the wall...

Страница 24: ...with the 3 screws The temperature stop must be calibrated at 38 C See the manual supplied with the thermostat 6 Place the frame on the tiles and seal the outer edge between the tiles and the frame wi...

Страница 25: ...8 Connect the water lines to the thermostatic tap Hot water supply Hand shower option shower set WWHR output Main shower option shower set Make sure that the water line has a gasket Handle in line wit...

Страница 26: ...The glass panel is secured with magnets Use glass suction cups to place the glass panel Place the glass panel without holes if you are not using the supplied thermostat 11 Install the control knobs S...

Страница 27: ...Installation manual Blue V4 5 27 12 Mount the main shower Use PTFE sealing cord 13 Mount the hand shower Elbow connection is not included...

Страница 28: ...3 Calibration and maintenance...

Страница 29: ...ly approx 2 liters of water 38 Off When you turn on the Blue for the first time or when the power is reconnected or turned on you will hear the sound of the pump pumping out the water This will take a...

Страница 30: ...describes the cleaning and maintenance intervals The table below is an overview of maintenance We recommend that you never use aggressive cleaning agents such as thinner or acetone This may vary per...

Отзывы: