background image

Содержание HBQ100

Страница 1: ...uidos mantenimlento y la garanffa Avec service et garantie Room Air Conditioners for Double Hung Windows Acondicionadores de aire ambiental para ventanas dobles Ciimatiseur d air individuel pour fen_tres _ guillotine mo 5 000 10 000 BTU S ...

Страница 2: ...in enfriamientn Ventitaci6n del cuarto sin enfriamiento PANEL DE CONTROL ELECTR_NtCO Funciones de 1o5 cont_otes Operacidn de on am onto Circulacidn de aire sin enfrian_iento Ventilaci6n del cuarto sin enfriamientn Orientaci6n de la corrienze de aire Unidad con rejilla directriz ajustabte Limpieza dot fittro de aire Servicio y Garantia 19 Enfriamiento insuficiente Sila unidad no se enciende Necesid...

Страница 3: ...CTRICAL REQUIREMENTS D Grounded three prong wall receplacle Three prong grounding plug D Single outlet grounding wall receptacle Important Grounding Requirements 1 Air conditioner has a three prong grounding plug on power suppIy cord which must be plugged into properly grounded three prong walI receptacle for your protection against possible shock hazard For models up to and including 7 5 amperes ...

Страница 4: ...ig 5 n rl o 9 i11 D Top bar Screws Bottom bar Cabinet Installation in Normal Width Window 1 Open and marl center line of window Dependh_g on the size of your unit attach one leveling bracket on the center line of the window or one 8 to the right and one 8 to the left of the center line Brackets may be attached to window sitl in either direction for maximum support depending on the depth of the win...

Страница 5: ...ase grip on air conditioner until lower window sash is in final position Fig 9 T Secure top of filler panels by driving 5 8 long wood screws through top mounting holes into window sash Fig 9 8 Secure bottom of filler panels by driving 5 8 long screws into window sill through filler panel tabs Fig 9 1 1 4 space rll llllll ii _ Levelingbracket Window sill SIDE VIEW Silledge Screw Caution Do ool dril...

Страница 6: ...teps 1 through 7 of preceding instructions Pgs 2 3 3 Close window until it touches behind air conditioner top bar Fig 8 4 Fasten lower window sash to window frame use finishing nails wood screws or L brackets Fig 9 5 If filler is required on sides of air conditioner cut plastic foam sea to size and fill both sides 6 Cut plastic foam seal to width of window and install between upper and Iower windo...

Страница 7: ...ctions is selected Thermostat The Thermostat Control adiusts the sensitivity of the unit thermostat which regu ates timeroom temperature by automatically turn ing the compressor on and off The cooIer the setting the cooler the room temperature will be Cooling Operation 1 Close the vent door 2 Turn the Thermostat Control to Cooler 3 Turn the Master Control to H COOL 4 if the room becomes to cool fo...

Страница 8: ...etting in increments of 1 from 00 to 24 Check Filter Light Reset After 250 hours of usage the Checl Filter light will turn on At this time the filter needs to be removed and cleaned see page 8 After tile filter is cteaned and repositioned depress the Reset button This w restart the counter and turn the light off Mode Control The Mode Control has three settings FAN COOL and ENERGY SAVER A green lig...

Страница 9: ...rn the unit on or off To turn the unit ON using the Timer Depress the timer key when the power is off the display will read 00 Adjust to the desired number of hours before TURN ON using the Temperature Timer Hour Controls The display will automati cally return to the set temperature after approxi mately 10 seconds To turn the unit OFF using the Timer Depress ti_e timer key when the power is on the...

Страница 10: ...w Unit with adjuctable louvers Unit is engineered with adjustable louvers to dffect d_scha_geairflow Louvers are manually adjusted by moving levers in direction of desired aidjow Fig 10 Cleaning Air Filter EVERYTWO WEEKS Clean 1he filter 1 Turn Master Control to OFF 2 Remove the air fgter by grasph_g the top corners and pulling it up and out of the unit Fig 10 3 Wash in hot soapy water rinse and s...

Страница 11: ... your country Room Air Conditioner Warranty dA ithin the48 contiguous UnitedStates stateof Hawaii theDistrictof COlumbia Pue_oRicoand Canada Full One Year PartsandLabor Warranty During the first year after the date of original pur chase Hampton Bay will through a network of authorized servicers and free of charge to the owner or any subsequent user repair or replace any parts which are defective i...

Страница 12: ...on or limitation of incidental or consequen tial damages so the above limitations or exclu sions may not apply to you This warranty gives you specific legal rights and you may also have other rights which may vary from state to state No warranties are made for units sold outside of tl_e above stated areas Your distributor or final seller may provide a warranty on units sold out_ side of these area...

Отзывы: