HAMPTON BAY 7114-01 Скачать руководство пользователя страница 1

1

Item #1001-419-054

Model #7114-01

USE AND CARE GUIDE

NO CUT EASY INSTALL VENTILATION FAN

Questions, problems, missing parts? Before returning to the store, 

call Hampton Bay Customer Service

8 a.m. - 7 p.m., EST, Monday-Friday, 9 a.m. - 6 p.m., EST Saturday

1-855-HD-HAMPTON

HAMPTONBAY.COM

 

THANK YOU

We appreciate the trust and confidence you have placed in Hampton Bay through the purchase of this ventilating bath fan. We strive to 

continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. 

Thank you for choosing Hampton Bay!

 

Содержание 7114-01

Страница 1: ...onday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM THANK YOU We appreciate the trust and confidence you have placed in Hampton Bay through the purchase of this ventilating bath fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton...

Страница 2: ...ent to prevent back drafting See the standards of NFPA National Fire Protection Association and ASHRAE American Society for Heating Refrigeration and Air Conditioning Engineers and the local building code authorities 9 Do not use this fan with any solid state control device such as a remote control dimmer switch or certain timers Mechanical timers are not solid state devices 10 This ventilation fa...

Страница 3: ...e the connector on stranded wires Strip wires 3 8 1 2 Grip the wire firmly and push the stripped end of the wire into the open port of the connector Use only one conductor per port Verify the stripped end of the wires is fully inserted to the back of the connector Quick connect House wires Product wires NOTE Important wire information Maximum temperature rating 105 C 221 F 600 volts maximum for bu...

Страница 4: ...than the purpose SHALL VOID THIS WARRANTY Shipping costs for return product as part of a claim on the warranty must be paid for by the customer Contact the Customer Service Team at 1 855 HD HAMPTON or visit www HAMPTONBAY com Warranty Pre installation PLANNING INSTALLATION Before beginning assembly of the product make sure all parts are present Compare parts with the package contents list and hard...

Страница 5: ...5 HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance Pre installation continued PACKAGE CONTENTS Part Description Quantity A Fan body 1 B Grille 1 C Duct connector 1 A B C ...

Страница 6: ...box cover from the fan housing Remove the wiring knockout from the wiring box cover with a flathead screwdriver not included 2 Fan housing placement Joist or wall stud Place the fan housing next to a ceiling joist or wall stud The fan housing should be level and perpendicular to the joist or stud 3 Mount the fan housing Joist or wall stud Mount the fan housing to the joist using nails not included...

Страница 7: ...ted you must determine what each house wire represents before connecting You may need to consult an electrical contractor to determine safely Push the wires back through the hole Reattach the wiring box cover 5 Install the duct Ceiling 3 in duct Duct tape or clamp Install a circular 3 in duct not included and secure it with duct tape or clamps neither included Finish ceiling work The ceiling hole ...

Страница 8: ...eiling opening Measure the opening to assure it is large enough to accom modate the new fan body A 7 50 in x 7 25 in NOTE 7 25 inch side of the opening should be flush with the joist 3 Enlarge the opening optional 7 50 7 2 5 If this fan is not replacing an old fan be sure to cut a 7 50 in x 7 25 in opening for the fan body A MAKE SURE THE 7 25 IN SIDE OF THE OPENING IS FLUSH WITH THE JOIST FOR INS...

Страница 9: ...he wire through the hole and into the junction box not included Using a quick connector secure 120 VAC house wiring from the wall switch to the fan as shown in the wiring diagram on page 3 NOTE Unit can be mounted in a ceiling or wall CAUTION If the electrical wires do not match the colors listed you must determine what each house wire represents before connecting You may need to consult an electr...

Страница 10: ...to the joist or stud using nails not included where indicated by arrows inside the fan housing 10 Reattach the motor assembly Plug the motor assembly back into the power unit Reattach the motor assembly using the three screws 1 removed in step 4 11 Install the grille Pinch the mounting springs on the grille B and insert them into the narrow rectangular slots inside the fan Push the grille B up tow...

Страница 11: ...r Service The bend in the duct is too close to the fan discharge Be sure you do not have any sharp bends in the duct closer than 18 in to the fan discharge The fan discharge is reduced to fit a smaller duct Use the recommended size ducting to reduce fan noise The fan body is not attached securely Be sure the fan is securely attached to the ceiling joists The fan is not clearing the room There is i...

Страница 12: ...ons problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for future use ...