background image

1

HAMPTONBAY.COM

Please contact 1-855-HD-HAMPTON for further assistance.

LED LOW VOLTAGE PATH LIGHT

Use and Care Guide

NOTE

: Do not use a hammer. If the ground is 

hard, use water to soften or a trowel to loosen 
the soil.

Attaching and installing the 
light

Attach the fixture head (A) to the post (B) by inserting
the fixture head (A) into the upper end of the post (B)
and then twisting clockwise.

Insert the fixture wire (2) into the groove located on
the top of the ground stake (C).

Attach the post (B) to the stake (C) by placing the
bottom of the post (B) onto the top of the stake (C)
and twisting clockwise.

Prepare a hole in the installation location. Use a
screwdriver to prepare the installation hole to ensure
that the hole is not larger than the stake (C).

Install the fixture in the ground by pushing on the foot
step (1) on the stake (C). Do not push on the fixture
head (A).

1

WARNING:

 Do not install the light within 10 ft. 

(3 m) of a pool, spa, or fountain.

A

B

D

2

1

C

D

Assembly and Installation

Item #1001 513 111
Model #29156

Connecting the wires

2

IMPORTANT

:

• Protect the wiring by routing it in close proximity to the light, fitting, 

or next to a building structure such as a house or a deck. 

• Do not bury the wiring by more than 6 in. (15.24 cm) in order to 

connect to the main secondary wire. 

• Do not submerge fixtures in water.

CAUTION: 

The wire from the low voltage power unit shall be 12-16 AWG 

type underground Low Energy Circuit Cable.

Detach and place the wire connector (D) on opposite sides of the low voltage cable (not
included) from the transformer (not included) where the fixture will be located.

Align and fit the main low voltage cable vertically in the slot of the wire connector as shown.

Press the wire connector (D) together until fully seated and locked around the cable. Pre-set
prongs will pierce the cable insulation and establish contact. Turn on the power unit. If the
light fixture does not turn on, repeat operations 2 and 3.

Once the clip-on connector is in place, we recommend to wrap it with electrical tape (not
included) for additional protection.

WARNING:

 The connector contacts (D) have sharp edges for piercing the 

main low voltage cable. To avoid injury, do not touch the metal contacts.

PACKAGE CONTENTS

A - Fixture head x 

12

B - Post x 

12

C - Stake with foot step x 

12

D - Connector with 12 in. wire length (attached to fixture) x 

12

A

B

C

D