background image

5

Using the Allergen Reducer

Before First Use: 

Be sure to remove all packing materials. The filter is packed in a

plastic bag inside the Allergen Reducer for shipping. 

1. For model 04381: 

To remove the

front grille,
press on the
grille release
buttons on
each side of
the grille and
pull towards
you.

For model 04371: 

To remove the

front grille,
grasp each
side of the
grille and pull
towards you.

2.

Remove the plastic bag from the 
filter then replace the filter in the unit.

3.

To close the front grille of the Allergen
Reducer, position the grille on the 
front of the unit and push until it 
snaps into place.

4.

Ensure the Allergen Reducer is in the
OFF position.

5. 

Plug in the Allergen Reducer.

6.

Select desired fan speed.

NOTES:

• The life of the filter is determined by

use. If the Allergen Reducer is used
continuously, it may need to be
replaced after 1 month. If only used
occasionally, it may last up to 4 months.

• Filter life will depend on use and 

allergy season.

Replacing the Filter

1. 

Turn off and unplug Allergen
Reducer. Remove the front grille
then remove the used filter by grip-
ping the sides and pulling outward.
Discard the used filter. It cannot be
cleaned.

2.

Obtain a replacement filter. Insert the
unwrapped filter.

NOTE:

Improper filter installation will

result in poor air filtration.

Purifier

Room Size

Model

(sq. ft.)

Filter

04371

110 ft

2

04711

04381

210 ft

2

04712

The Allergen Reducer is designed to
filter the room three times per hour at
high speed. Factors such as room
shape and ceiling height can affect
this rate. It is normal that the air flow
will be reduced as the filter becomes
clogged. Replace the filter as needed.

To order replacement filters, call
Customer Service:

U.S. at 1-800-851-8900
Canada at 1-800-267-2826

To Order Replacement Filters

840117900 ENv00  8/27/03  11:28 AM  Page 5

Содержание TrueAir 840117900

Страница 1: ...840117900 Important Safeguards 2 Parts and Features 3 How to Assemble and Use 4 How to Clean 6 Troubleshooting Guide 6 Customer Service 7 In USA 1 800 851 8900 In Canada 1 800 267 2826 840117900 ENv00...

Страница 2: ...use this Allergen Reducer with any solid state speed control device 12 Do not use the TrueAir Allergen Reducer in unheated areas such as a garage or porch Consumer Safety Information This appliance is...

Страница 3: ...mmable or volatile vapors Instruct children never to interfere with the unit Use with a properly functioning electrical outlet only This product is not a toy For adult use only Do not use near cooking...

Страница 4: ...es such as stoves radiators or heaters To reduce electrical noise and interference do not place on or near or plug into the same outlet as TVs baby monitors or cordless phones Do not place in direct s...

Страница 5: ...continuously it may need to be replaced after 1 month If only used occasionally it may last up to 4 months Filter life will depend on use and allergy season Replacing the Filter 1 Turn off and unplug...

Страница 6: ...clean dry cloth only 3 To clean the grille wipe with a damp cloth or use a vacuum cleaner to remove lint or debris 4 Do not use detergents solvents or spray cleaners No part of the Allergen Reducer sh...

Страница 7: ...D AND ALL CLAIMS FOR SPECIAL INCIDENTAL AND CONSEQUENTIAL DAMAGES ARE HEREBY EXCLUDED There is no warranty with respect to the following which may be supplied with this product the filter This warrant...

Страница 8: ...8 trueair com 8 03 840117900 HAMILTON BEACH PROCTOR SILEX INC PROCTOR SILEX CANADA INC 263 Yadkin Road Southern Pines NC 28387 Picton Ontario K0K 2T0 840117900 ENv00 8 27 03 11 28 AM Page 8...

Страница 9: ...ir 840117900 Pr cautions importantes 2 Pi ces et caract ristiques 3 Assemblage et utilisation 4 Nettoyage 7 D pannage 7 Service la client le 8 Aux U 1 800 851 8900 Au Canada 1 800 267 2826 840117900 F...

Страница 10: ...our r duire le risque d incendie ou de choc lectrique ne pas utiliser ce r ducteur d allerg nes avec un dispositif de contr le de vitesse transistoris 12 Ne pas utiliser le r ducteur d allerg nes True...

Страница 11: ...e aux enfants de ne jamais manipuler l appareil Utiliser uniquement sur une prise de courant qui fonctionne convenablement Ce produit n est pas un jouet Seuls les adultes peuvent l utiliser Ne pas uti...

Страница 12: ...est bien install avant l utilisation AVERTISSEMENT Pour r duire le risque de choc lectrique ne jamais brancher le r ducteur d allerg nes les mains mouill es Toujours d brancher le r ducteur d allerg...

Страница 13: ...t riel d emballage Le filtre a t plac dans un sac de plastique l int rieur du r ducteur d allerg nes pour l exp dition Choix du bon endroit suite 1 Pour le mod le 04381 Pour enlever la grille avant ap...

Страница 14: ...perficie Num ro de la pi ce de mod le pieds carr s Filtre 04371 110 pi2 04711 04381 210 pi2 04712 Le r ducteur d allerg nes est con u pour filtrer la pi ce trois fois par heure haute vitesse Les facte...

Страница 15: ...e l essuyer avec un chiffon humide ou utiliser un aspi rateur pour enlever la charpie ou les d bris 4 Ne pas utiliser de d tergents solvants ou produits de nettoyage en a rosol Aucune partie du filtre...

Страница 16: ...S LES R CLAMATIONS POUR DOMMAGES SP CIAUX ET INDIRECTS SONT PAR LES PR SENTES EXCLUES La garantie ne s applique pas aux accessoires suivants qui pourraient tre vendus avec ce produit le filtre Cette g...

Отзывы: