background image

Revision Description: 
Request Number: 
Issue Code(s): 

Updated Information

DOC3934

CS, SP 

Revision Date:

07/19/12

Document #: 

Approved by:

520007100

 

DOC3934

Page:

1

of 

5

Rev:

B

ENG-FRM-RIC-4.32, Rev. E 

Technical Data Sheet 

HBH 650

 

PROPRIETARY RIGHTS NOTICE  This document and all information contained within it is the property of Hamilton Beach Brands, Inc. (HBB).  It is confidential and 
proprietary and has been provided to you for a limited purpose.  It must be returned or destroyed upon request.  Disclosure, reproduction or use of this document and 
any information contained within it, in full or in part, for any purpose is forbidden without the prior written consent of HBB.  No photographs may be taken of any article 
fabricated or assembled from this document without the prior written consent of HBB.

 

 

 

 

 

 

Trouble Shooting Guide HBH650 L Series and Above

 

 

Symptom: 

Unit is extremely noisy

Cause: 

Possible worn bearing on cutter assembly. Remove container from 

blender. Slowly turn the cutter assembly from the bottom of the container. If it is 
hard to turn or feels loose/wobbly replace cutter assembly. Possible worn drive 
coupling. Check the teeth of the drive coupling. If worn, replace drive coupling 
outlined in repair guide. 

 

Symptom: 

Constant red light from cycle counters on bottom of PC board. 

Cause: 

Fault condition. Turn the machine upside down the indicators will be in the 

right, front corner of the machine. A constant red light tells you that there is a fault 
that will require more investigation. 

 

Symptom: 

During a normal cycle the machine stopped. 

Cause: 

The unit has possibly overheated without notice to the warning lights 

indicating to run a cool down cycle. Unplug the machine 15-30 minutes. Plug in 
the unit and try to operate. If the problem persists proceed to repair guide. 

 

Symptom: 

No lights when power button is depressed. 

Cause: 

No power. Ensure the power outlet is operational. Ensure that the 

circuit breaker on the bottom of the machine has not tripped. Ensure power 
is operational. 

 

Symptom: 

No jar sensor indicator 

Cause: 

PC board, membrane switch, ribbon connector or jar sensor, touch pad. 

 

Symptom: 

Unit functions but not as intended. 

Cause: 

Check the ribbon cable and connector for evidence of shorting. The 

ohms at the ribbon cable connector should be less than 300 and voltage 
should be about 9V. 

Cause: 

Ribbon cable not properly sealed. Separate the two halves of ribbon 

cable and apply Dow 748 RTV Electric grade sealant. Add mylar cover over 
ribbon cable connection if missing. 

 

Symptom: 

Power switch fails. 

Cause: 

Check connection. Ensure the PVC switch cover is present  

(moisture protection). 

 

Symptom: 

Timer switch is binding. 

Cause: 

Remove timer dial. Gently clean dial, rubber boot and touch pad. 

Grease inside diameter of rubber seal and replace. 

 

 