Warning - renovation work, work in
the vicinity of the smoke detector

• Reinstall all correctly functioning smoke

detectors in their installation locations and
immediately replace any smoke detectors
that are no longer functioning correctly with
new devices.

• After installation, check all smoke detectors

for their function as described in

7.1. Testing

.

4.3 Installation locations and optimal
placement of smoke detectors

Note

The installation locations and positions of the
smoke detectors shown are only examples based
on average apartments and houses and are only
intended as a guide.

4.3.1 Not permitted installation locations

• Do not install smoke detectors in garages - the

combustion residues/exhaust gases produced
when starting a motor vehicle can trigger false
alarms.

• Unsuitable rooms are those in which temperatures

fall below 0°C or rise above 40° C or in which the
humidity is more than

93%.

• Do not attach the smoke detector e.g. to the

ceiling of a caravan or similar rooms. The sun's
rays heat the air quickly here, so that possible
smoke is thereby prevented from reaching the
smoke detector and triggering the alarm.

4.3.2 Installation locations with restrictions

• Also take into account the information in

4.2. Reasons for false alarms

.

• Smoke detectors must only be installed in kitchens

and wet rooms (bathrooms) if the restrictions
are observed and at the same time false alarms
caused by kitchen and water vapour can be
excluded.

• When installing the smoke detector near

dishwashers, washing machines, ovens, etc., keep
it at least 3 m away from these areas.

• When installing the smoke detector near ventila-

tion shafts or openings for heat and cold supply,
keep it at least 1 m away from these areas. The
air could blow the smoke away from the smoke
detector and thus interrupt or prevent the alarm.
Make sure that the air movement in such rooms
does not affect the penetration of

fi

re smoke into

the smoke detector.

• Perforated ceilings used for ventilation in forcibly

ventilated rooms must be closed within a radius
of 0.5 m around the smoke detector.

• In very dirty, dusty, greasy or insect-infested

areas, smoke detectors can become excessively
contaminated with dust and dirt, resulting in false
alarms or impaired smoke detection.

4.3.3 Standard rooms

• Smoke and combustion residues rise upwards

to the ceiling and then spread horizontally. The
ideal installation location is on the ceiling, in the
middle of the room.

• When installing, make sure that the smoke

detector is at least 0.5 m away from any side
wall and larger furnishings, e.g. high cupboards
(see Fig. 2a).

• A smoke detector is only permitted for room sizes

up to max

.

60 m

2.

If the room size exceeds 60 m

2

,

use additional smoke detectors. For example, at
least two smoke detectors should be installed in
rooms between 60 m² and 120 m² in size.

• A smoke detector is only approved for installation

heights up to max. 6 m. If the room height
exceeds 6 m, additional smoke detectors must be
installed at several levels.

max.

6 m

min. 0.5 m

min. 0.5 m

min. 0.5 m

2a

Содержание GS526

Страница 1: ...Smoke Alarm GS526 Rauchwarnmelder 00 223842 D GB Operating Instructions Bedienungsanleitung...

Страница 2: ...f any kind of damage the smoke detector must be replaced Draw up an escape plan in case of emergency see 6 1 for instructions The escape plan recommendation Warning of hearing damage The smoke detecto...

Страница 3: ...om Child s room Bath room Corridor Smoke detector for minimum protection Smoke detector for optimal protection Installation locations with restrictions In buildings with several residential units smok...

Страница 4: ...ork Construction work cleaning work with dust generation Strong electromagnetic effects Significant temperature fluctuations which can lead to condensation of the humidity in the smoke detector etc If...

Страница 5: ...hen and water vapour can be excluded When installing the smoke detector near dishwashers washing machines ovens etc keep it at least 3 m away from these areas When installing the smoke detector near v...

Страница 6: ...itchens that serve as escape routes Corridors and rooms with a width 1 m the ideal installation location is on the ceiling centrally between the walls Corridors with a width 3 m in corridors with a ma...

Страница 7: ...rooms For pitched roofs with a roof pitch 20 the smoke detector must be installed at a distance of at least 0 5 m and max 1 m from the gable peak see Fig 5a 0 5 m 0 5 m 20 5a Note the following for r...

Страница 8: ...s are higher than 0 2 m and the area of the individual ceiling panels is less than 36 m each the joists beams are not relevant and are to be seen as part of the ceiling The smoke detector can be insta...

Страница 9: ...tach the smoke detector to the base plate affixed to the installation location by inserting the latching hooks into the openings provided and turning the smoke detector clockwise Check that the smoke...

Страница 10: ...Mute mode in the case of a false alarm Warning Before activating mute mode clarify the cause of the alarm and make sure that there is no further danger Note Cigarette smoke will not normally trigger...

Страница 11: ...ce the smoke detector with a new device Ensure that all specifications are met according to the installation location see 4 Installation In the event of structural recognisable changes check whether t...

Страница 12: ...h red LED flash repetition of alarm scheme Temperature range 5 C 40 C 12 LED and acoustic signalling LED flashes every 40 seconds The smoke detector is working properly LED flashes every second and al...

Страница 13: ...Installationshinweise Bei jeglicher Art von Besch digung ist der Rauchwarnmelder auszutauschen Erstellen Sie f r den Notfall einen Fluchtplan Hin weise dazu finden Sie unter 6 1 Der Fluchtplan Empfeh...

Страница 14: ...rschriften f r die Installation 4 1 Allgemeine Hinweise F r die Mindestabsicherung wird empfohlen je einen Rauchwarnmelder in jedem Schlaf und Kinderzimmer sowie in Fluren die zu diesen R umen f hren...

Страница 15: ...und Umgebungen neigen aufgrund ihrer typischen Nutzung m glicherweise beg nstigt zur Ausl sung von Fehlalarmen Darunter fallen St rfaktoren wie z B Wasser Koch und sonstige D mpfe Schwei L t Trenn un...

Страница 16: ...eitig Fehlalarme durch K chen und Wasserdampf ausgeschlossen werden k nnen Halten Sie bei der Installation des Rauchwarn melders in der N he von Geschirrsp lern Waschmaschinen fen etc mindestens 3 m A...

Страница 17: ...4 3 8 Wandmontage beschrieben zu bevorzugen Flure und R ume mit einer Breite 1 m Der ideale Montageort ist an der Decke mittig zwischen den W nden Flure mit einer Breite 3 m In Fluren mit einer maxim...

Страница 18: ...3 5 Standard R ume Bei Spitzd chern mit einer Dachneigung 20 ist der Rauchwarnmelder in einer Entfernung von mind 0 5 m und max 1 m von der Giebelspitze anzubringen siehe Bild 5a 0 5 m 0 5 m 20 5a Be...

Страница 19: ...er einzelnen Deckenfelder jeweils kleiner als 36 m sind die Unterz ge Balken nicht relevant und als Bestandteil der Decke zu sehen Der Rauchwarn melder kann auf einem Deckenfeld oder direkt auf dem Un...

Страница 20: ...gen Sie den Rauchwarnmelder auf der an der Montagestelle angebrachten Grundplatte indem Sie die Rasthaken in die vorgesehenen ffnungen einf hren und den Rauchwarnmelder im Uhrzeigersinn drehen Kontrol...

Страница 21: ...vieren kl ren Sie die Ursache f r den Alarm und vergewissern Sie sich dass keine weitere Gefahr besteht Hinweis Zigarettenrauch wird normalerweise den Alarm nicht ausl sen au er der Rauch wird direkt...

Страница 22: ...Risse im Geh use aufweist Sollte dies der Fall sein ersetzen Sie den Rauchwarnmelder durch ein neues Ger t Stellen Sie sicher dass alle Vorgaben entsprechend des Montageorts siehe 4 Montage eingehalte...

Страница 23: ...iederholung des Alarmschemas Temperaturbereich 5 C 40 C 12 LED und akkustische Signalisierung LED blinkt alle 40 Sekunden Der Rauchwarnmelder funktioniert ordnungsgem LED blinkt jede Sekunde und Alarm...

Страница 24: ...corresponding companies Errors and omissions excepted and subject to technical changes Our general terms of delivery and payment are applied Hama GmbH Co KG 86652 Monheim Germany Service Support www h...

Отзывы: