Hama GS 508 Скачать руководство пользователя страница 1

holes in the

ceiling or wall

plastic anchors

holder

two screws

housing

00

108875

Smoke alarm device

Rauchwarnmelder

“GS 508”

F

D

GB

Operating Instructions

Bedienungsanleitung

Thank you for choosing a Hama product.

Take your time and completely read the following instructions and information. Please keep these

instructions in a safe place for future reference. If you sell the device, please pass these operating

instructions on to the new owner.

1. Explanation of Warning Symbols and Notes

Warning

This symbol is used to indicate safety instructions or to draw your attention to specific hazards

and risks.

Note

This symbol is used to indicate additional information or important notes.

2. Package Contents

Photoelectronic smoke alarm with VdS test mark

Base plate

Mounting equipment

3 volt CR123A battery Lithium (permanently integrated)

These operating instructions

3. Safety Notes

Do not use the smoke alarm in the immediate vicinity of heaters, other heat sources or in direct sunlight.

Do not drop the smoke alarm and do not expose the device to major shocks.

Do not open the smoke alarm or continue to operate it in case of any damage.

To ensure the correct function of the smoke alarm, follow the mounting and installation information

given in these operating instructions.

Replace the smoke alarm in case of any damages.

Create an emergency escape plan (for further information, please refer to

6.1 Emergency Escape

Plan (Recommendation)

).

Attention: hearing damage possible. The alarm sound is very loud. Do not test the smoke alarm close

to the ear. Sound pressure level in alarm mode: min. 85dB.

Do not modify the product in any way. Failure to observe will result in the loss of any warranty.

Warning

Carbon monoxide, flames, heat, gases, etc. cannot be detected by the smoke alarm.

The installation of smoke alarms neither prevents fires, nor does it facilitate extinguishing of fires. Smoke

alarms are not warranted to protect lives and property. Smoke alarms are not a substitute for insurance.

Note

The battery is permanently integrated and cannot be removed. Dispose of the product as a whole

in compliance with the legal regulations.

The smoke alarm does not contain any radioactive substances.

4. Installation
4.1 Recommended Installation Locations

Note

In each apartment, place smoke alarms at least in every bedroom and nursery, as well as in the

hallways leading to these rooms and along escape routes.

If the total length of the hall is more than 10 m, install one smoke alarm on each end of the hallway.

Smoke and combustion by-products rise upward towards the ceiling before spreading horizontally.

The ideal installation location is on the ceiling in the middle of the room.

A single smoke alarm device is only permitted for rooms of up to 60 m

2

. If the room is larger than

60 m

2

, use additional smoke alarms.

A single smoke alarm is only permitted for a maximum installation height of 6 m. If the room

height exceeds 6 m, install additional smoke alarm devices at different height levels.

For a minimum level of safety, it is recommended to install one smoke alarm for each hall and stairway

on each floor, as well as in each bedroom and children’s room. (see Figure 2 and 3).

For achieving an optimal level of safety, install one smoke alarm in each room, hall, cellar room and

attic room, etc. – please observe

4.2 Installation Locations with Restrictions

.

In buildings with multiple living quarters, the installation of smoke alarms should be conducted

separately in each living quarter, as well as in all common halls and stairways.

In stairways, install the smoke alarm at the top of the stairs as a chimney effect often occurs, rapidly

drawing smoke into the upper floors.

For installation, make sure that the smoke alarm is mounted at least 50 cm away from each side wall

or any large piece of furniture, e.g. high cupboards (see Figure 1).

Note

The specified installation locations, as well as the depicted positions of the smoke alarms, are only

of exemplary nature on the basis of average homes and houses, and do only serve as a point of

reference.

Mounting the smoke alarm should be conducted by a qualified and certified electrician. Observe

all local and national electrical and building codes for installation.

4.2 Installation Locations with Restrictions

Smoke alarms should only be installed in kitchens and damp rooms (bathrooms) if the restrictions from

Figure 1 are observed, and false alarms caused by kitchen vapours or water steam can be ruled out.

For installing the smoke alarm near dishwashers, washing machines, ovens, etc., observe a minimum

installation distance of 3 metres away from these appliances.

For installing the smoke alarm near ventilation shafts or openings for heat and cold air supply, observe

a minimum installation distance of 1 metre away from such areas. The air stream could blow the smoke

away from the smoke alarm, and therefore interrupt the alarm or prevent the alarm from being triggered.

Do not install smoke alarms in garages – the combustion by-products/ exhaust fumes caused by

starting a car can trigger false alarms.

For peaked roofs with an angle > 20°, the smoke alarm should be installed at a distance of at least

50 cm and no more than 1 m away from the gable peak; see Figure 1. Roofs with angles of ≤ 20° can

be handled the same as horizontal ceilings.

Rooms in which either temperatures fall below 0°C or rise above 40°C, or the air humidity reaches

more than 93% are not suitable for installation.

Do not install the smoke alarm on e.g. the ceiling of caravans or similar rooms. Sunlight will quickly

heat up the air and prevent any smoke from penetrating and triggering the smoke alarm.

In very dirty, dusty or grimy areas, or in areas with insect infestation, smoke alarms can be exposed to pol-

lution by excess levels of dirt and dust, which can result in false alarms or impairment of smoke detection.

Note

Generally, the alarm signal of the smoke alarm is loud enough to warn persons. However, situations

may arise in which the persons are unable to hear (e.g. high ambient noise level, persons with very

deep sleep and/ or hearing impairment, persons under the influence of drugs or alcohol, etc.). Install

additional, special smoke alarms if you suspect this being the case with people in your environment.

4.3 Mounting the Base Plate

Hold the base plate of the smoke alarm against the installation location – the two mounting holes can

be used as a template to mark the positon of the drill holes.

Warning

Prior to drilling and mounting, make sure that there are no electricity, water, gas or any other

supply lines in the area of the installation location.

On wooden ceilings or exposed beams, drill holes with a depth of approx. 20 mm, using a 2.5 mm drill

bit. Use the supplied screws without the anchors.

For cement or brick, use a drill bit with a maximum diameter of 5 mm (measure the supplied anchors

before) and drill approx. 25-30 mm deep so that the anchors can be inserted.

Insert the anchors (for cement or brick).

Mount the base plate of the smoke alarm using the supplied screws.

5. Putting into operation
5.1 Activation

Note

The smoke alarm must be activated prior to use.

Press and hold the

TEST

button on the smoke alarm for ca.

3-4 secs

until the LED lights up.

Then, immediately release the

TEST

button. The smoke alarm will generate a short signal sound to

indicate successful activation.

After this,

check the functionality

by pressing the

TEST

button. This check must generate an

immediate alarm signal.

If no alarm signal is generated upon pressing the

TEST

button, the smoke alarm is

not activated!

Repeat the activation

until the smoke alarm reacts correctly to the test!

Upon successful activation and during correct function, the LED keeps flashing briefly every 40 seconds.

5.2 Fastening the Smoke Alarm

Fasten the smoke alarm to the base plate mounted in the installation location by guiding the snap-in

hooks into the intended openings, and clockwise rotation of the smoke alarm.

Check the secure fastening of the smoke alarm to the base plate.

After its mounting, the correct function of the smoke alarm must be tested. For testing, press the

TEST

button. An alarm signal is generated.

If no successful alarm signal is generated, repeat the activation steps described in

5.1 Activation

6. Operation
6.1 Emergency escape plan (Recommendation)

Discuss and create an emergency escape plan together with your family and/ or cohabitants.

If possible, also take alternative escape routes into account, as fire could block the standard routes.

Demonstrate the alarm signal of the smoke alarm to your family and/or cohabitants (see

7.2 Alarm Sim-

ulation

) and make sure that each person is informed about adequate behaviour in the event of an alarm.

Make sure that also your children are able to recognize an alarm case, and that they can see them-

selves to safety.

Determine a location outside of your house as a meeting point in the event of an alarm.

If necessary, practise the appropriate behaviour during alarm at regular intervals. Practising helps your

family and/or cohabitants to quickly leave the house in an orderly fashion in the event of an alarm.

6.2 Alarm Event

In the event of an alarm – as soon as the smoke alarm detects combustion particles or when perform-

ing an alarm simulation (see

7.2 Alarm Simulation

) – the

LED

keeps flashing once per second, and

an audible alarm signal sounds.

Alarm signal (sound sequence): 3x signal tone, short pause, 3x signal tone, short pause, 3x signal

tone, short pause, …

The alarm signal sound will persist until the smoke alarm is no longer able to detect any combustion

particles in the air – the alarm silencing mode is activated (see

6.4 Alarm Silencing Mode

), or the

alarm simulation is ended.

Warning

The triggering of an alarm always necessitates your immediate attention and the initiation of

adequate measures!

6.3 Behaviour in the Event of Alarm (Recommendation)
Rescue Yourself and Others

Remain calm!

Warn other family members and/ or cohabitants!

Immediately leave the building and close all doors and windows on your escape route – if it is safe to

do so –, to restrict the spread of smoke and fire.

After leaving the house, go to your prearranged meeting place and ensure that all persons have left

the house.

Call the Fire Service

Call the fire service as soon as you are in safety.

Attempts to Extinguish the Fire

Only initiate attempts to extinguish the fire on your own if you do not endanger yourself (or others),

and if you have adequate extinguishing appliances at your disposal.

6.4 Alarm Silencing Mode (for false alarms)

Warning

Prior to activating the alarm silencing mode, determine the cause for the alarm, and make sure that

there is no further danger!

Note

Cigarette smoke will generally not trigger the alarm, unless the smoke is blown directly into the

smoke alarm.

Cooking vapours can trigger an alarm if the smoke alarm is located near a cooking area.

If an alarm is triggered, verify whether or not a genuine emergency situation exists.

If fire or smoke is present, call the fire service and behave in the manner described in

6.3 Behaviour in the Event of Alarm (Recommendation)

.

Upon ensuring that a false alarm was triggered, press the

TEST

button of the smoke alarm to activate

the alarm silencing mode and mute the alarm signal for approx. 10 minutes.

The red LED will then flash every 8 seconds to indicate that the smoke alarm is in the alarm silencing

mode.

The smoke alarm is reset automatically after approx.10 minutes. If smoke particles are still present

after this time, the alarm signal is triggered again.

The alarm silencing mode can be activated repeatedly.

7. Care and Maintenance
7.1 Test

Press the

TEST

button on the smoke alarm. The alarm signal sounds if the electronics, the sensor, the

horn and the battery are all functioning correctly.

Note

Immediately replace smoke alarms without correct function by new devices.

It is recommended to test the smoke alarm on a weekly basis in order to ensure its correct function.

• Only

test the smoke alarm by using the

TEST

button. Never use an open flame, a lighter, etc. to

simulate an alarm, and to test the functionality.

7.2 Alarm Simulation

Press and hold the

TEST

button on the smoke alarm to simulate an alarm situation. Like in a genuine

alarm event, the LED keeps flashing once per second, and an audible alarm signal sounds as long as the

TEST

button is pressed.

7.3 Battery/ Replacing the Smoke Alarm

The battery service life of the 3V lithium battery in this smoke alarm is ten years. The smoke alarm

indicates a weak battery by emitting an audible signal tone, and the LED flashes repeatedly every

40 seconds. Weak battery indication is given for a period of at least 30 days. Please replace the smoke

alarm within this period with a new device.

When the smoke alarm is indicating a weak battery, the signal tone can be interrupted for 10 hours by

pressing the

TEST

button. During this period, the smoke alarm is generally still capable of detecting

smoke. However, take care to immediately replace it with a new device.

Note

Both the battery service life and the service life of the smoke alarm itself (in particular of the sensor)

are limited in time. For this reason, observe the Date of Replacement printed on the device prior to

mounting the smoke alarm. Replace the smoke alarm at the recommended date with a new device,

even if a discharged battery is not indicated.

7.4 Care

Regularly clean the smoke alarm (at least once per month) to free the device from dust, dirt and

residues. Use a vacuum cleaner with a soft brush and carefully vacuum the smoke alarm from all sides

and on all covers.

Warning - Renovation works

Dismount the smoke alarm or cover it to keep it dust-free prior to starting the renovation works.

Ideally, store the device in a safe and dust-free location during the period of the renovation.

Make sure that no paint is applied to the smoke alarm, and that no residue of masking tape is left

on the enclosure.

Dust, paint, tape and other dirt can impair the sensitivity of the alarm trigger, and can potentially

render the smoke alarm inoperative and without function.

Remount all correctly functioning smoke alarms back on their installation location and immediately

replace smoke alarms without correct function by new devices. Check all smoke alarms for correct

function after mounting, as described under

7.1 Test

.

8. Warranty Disclaimer

Hama GmbH & Co. KG assumes no liability and provides no warranty for damage resulting from

improper installation/mounting, improper use of the product or from failure to observe the operating

instructions and/or safety notes.
9. Service and Support

Please contact Hama Product Consulting if you have any questions about this product.

Hotline: +49 9091 502-115 (German/English)

Further support information can be found here: www.hama.com
13. Recycling Information
Note on environmental protection:

After the implementation of the European Directive 2002/96/EU and 2006/66/EU in the national

legal system, the following applies: Electric and electronic devices as well as batteries must not

be disposed of with household waste. Consumers are obliged by law to return electrical and

electronic devices as well as batteries at the end of their service lives to the public collecting

points set up for this purpose or point of sale. Details to this are defined by the national law of

the respective country. This symbol on the product, the instruction manual or the package indicates that a

product is subject to these regulations. By recycling, reusing the materials or other forms of utilising old

devices/Batteries, you are making an important contribution to protecting our environment.

14. Manufacturer and Licensee:

Ningbo Siterwell Electronics Co.,Ltd

No.76 Haichuan Road, Chuangye

Zone B, Jiangbei, Ningbo, China

Distributed by

Hama GmbH & Co KG

86652 Monheim/Germany

www.hama.com

All listed brands are trademarks of the corresponding companies. Errors and omissions excepted,

and subject to technical changes. Our general terms of delivery and payment are applied.

00108875/10.15

G 214063

0786

0786-CPR-21388

3

Bedroom

Child

room

Hall

Living

room

Kitchen

Basement

Workshop

2

Kitchen

Bedroom

Living room

Child rooms

Smoke alarm for minimum protection

Smoke alarm for optimum protection

Installation sites with restrictions

Bath-

room

Hall

4

LED

TEST button

1

ceiling

50 cm min.

ideal position

alternative

position

Dead space!

Do not mount

here!

Heat

and

smoke

from

fire

50 cm

100 cm

>20°

30–50

cm

10