Warnings

1. Use with clean, clear, fresh potable drinking water only!  Do not use with water that is microbiologically 

unsafe or of unknown quality without adequate disinfection before the system.

2. Connect Power Cord only to a grounded three prong electrical outlet with electrical power that:

a.  MUST be rated for this product as specified on product data label.

b.  MUST have over-current protection (e.g. Fuse, Breaker).

c.  MUST have Ground Fault Circuit Interrupt protection (GFCI).

d. 

These products are designed to operate on 20 to 105 PSI supply line pressure. If inlet pressure is

  above 105 PSI, a pressure regulator must be installed in supply line.  Any damage caused 

     by reason of connecting this product to supply line pressure lower than 20 PSI or higher than

     105 PSI is not covered by warranty

.

IMPORTANT

THIS IS AN INDOOR APPLICATION ONLY!

ALL SERVICE TO BE PERFORMED BY AN 

AUTHORIZED SERVICE PERSONNEL.

TOOLS/ITEMS REQUIRED

BUT NOT SUPPLIED

- SERVICE STOP VALVE WITH 3/8"

   COMPRESSION OUTLET

- FASTENERS FOR WALL TYPE (8 REQ’D.) 

- SLIP JOINT DRAIN UNION OR

   

COMPRESSION CLAMP

- 5/32" HEX-WRENCH

Model

HTHB-WF

To assure you install this model easily and correctly, PLEASE READ THESE 

SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK 

YOUR INSTALLATION FOR COMPLIANCE  WITH ALL PLUMBING, ELECTRICAL 

AND OTHER APPLICABLE CODES. FOLLOW ALL WARNINGS AND CAUTIONS 

CAREFULLY.  After installation, leave these instructions with the customer for future 

reference.

Installer

WARNING:

 Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA:

 Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT:

 Cancer et effets néfastes sur la reproduction - 

www.P65Warnings.ca.gov

Patent zurn-elkay.com/patents

Содержание HydroBoost HTHBSM-1A

Страница 1: ...n of connecting this product to supply line pressure lower than 20 PSI or higher than 105 PSI is not covered by warranty IMPORTANT THIS IS AN INDOOR APPLICATION ONLY ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL TOOLS ITEMS REQUIRED BUT NOT SUPPLIED SERVICE STOP VALVE WITH 3 8 COMPRESSION OUTLET FASTENERS FOR WALL TYPE 8 REQ D SLIP JOINT DRAIN UNION OR COMPRESSION CLAMP 5 32 HEX W...

Страница 2: ... LEGEND A RECOMMENDED WATER SUPPLY LOCATION 1 2 IPS MAXIMUM PIPE SIZE SERVICE STOP VALVE NOT FURNISHED B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D MAXIMUM PIPE SIZE C ELECTRICAL OUTLET THREE 3 CONDUCTOR GROUNDED LOCATE WITHIN SAFE REACH OF POWERCORD D 7 16 X 3 4 OBROUND MOUNTING HOLES FOR FASTENING BACKPLATE TO WALL FIG 2 B C A SIMPLY PUSH IN TUBE TO ATTACH TUBE IS SECURED IN POSITION PUSH I...

Страница 3: ...Cover from Bottle Filler by removing two 2 screws from bottom of unit Use a 5 32 hex wrench not supplied Remove and place aside new Filter Cartridge shipped inside Bottle Filler 2 Remove Back Panel from Bottle Filler by removing two 2 screws from top of unit that secures the Top Cover 3 Fasten Back Panel to structurally secure wall thru eight 8 7 16 obround holes with fasteners appropriate for wal...

Страница 4: ...a clean appearance gather and loop any extra Power Cord and secure to the underside of bottom Cover with supplied adhesive backed clip Instruction for Use 1 To activate water flow position mouth of water bottle or container under Dispensing Nozzle and in a continuous motion swing and hold container in front of Sensor Lens Hold until container is filled to level desired 2 To stop water flow pull co...

Страница 5: ...allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button for approximately 2 seconds until the display changes then release The display will change and scroll through two messages RST FLTR Reset Filter S...

Страница 6: ...e display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display sho...

Страница 7: ..._12PK 98543C 98544C 2000000503 98546C 98549C 98631C 2000000502 Filter WaterSentry Plus 12Pack Kit Electrical Package Kit EE Sensor Kit Solenoid Valve Replacement Kit Aerator Replacement Kit Hardware Waterway Parts Kit Electrical Package 220V Kit Solenoid Valve Replacement 220V WATERSENTRY PLUS FILTER PARTS LIST See Fig 3 ITEM NO PART NO DESCRIPTION 1 2 3 55898C 1000005553 70792C Filter Assy 3000 G...

Отзывы: