HVRGRN8WS*1C HVRGRN8WSNF*1C
1000001739 (Rev. P - 03/23)
Page 3
12
5
/16"
313m
m
FINISH
ED FLO
OR
HANG
ER
BR
AC
KET
1 3
/8"
35mm
1 3
/8"
35mm
5 3/4" 146m
m
5 3/4" 146m
m
E
F
LC
27"
68
6mm ADA
REQ
U
IREME
NTS*
13
7
/8"
35
2mm
18
3
/8"
467mm
25" 63
5mm
31" 787
mm
5/
16"
(8mm
) DI
A.
(5 H
O
LES)
3
1/2"
89mm
4
1/2"
114
mm
2 7
/16"
63mm
5" 12
7m
m
10" 25
4mm
11
/16"
18m
m
2
9/
16"
65mm
7
1/4"
185mm
A
D
B
E
6
1/4"
159
m
m
1
1/2"
38mm
C
4
9/
16"
116
mm
6 3/4" 172m
m
7" 178mm
7" 178mm
O
7/
16"
11m
m
MO
UNT
ING HO
LES
(6)
15" 381mm
3 3/
16"
82mm
52
1/
16"
1323mm
17
7
/8"
45
4mm
3
9/
16"
90m
m
18
1
/2"
471
mm
18
7
/8"
479
mm
31
13
/16"
80
8mm
RIM
HEIGHT
32
15
/16"
837mm O
RIFI
CE
HEIGHT
2 5/8" 67mm
39
1
/16"
991
m
m
AC
TIVA
TI
ON
SEN
SOR
21
3
/8"
54
3mm
2
1/2"
64mm
Fig. 2
*ADA
REQUIREMENT
*REQUISIT
O
DE A.D.A.
*EXIGENCE ADA
REDUCE HEIGHT BY
3" FOR INST
ALLA
TION OF CHILDREN'S
ADA
COOLER
*
LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED W
ATER SUPPL
Y LOCA
TION 3/8 O.D. UNPLA
TED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY
OTHERS) 3 IN. (76
mm
)
MAXIMUM OUT FROM W
ALL
La UBICACION 3/8 O RECOMENDADA
de
ABASTECIMIENT
O DE
AGUA. D. El
TUBO del COBRE de UNPLA
TED CONECT
A
TALONARIO CON
AP
AGO
(POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA
DE P
ARED
L’O.D de 3/8 d’EMPLACEMENT
DE PROVISION D’EAU RECOMMANDE. LE
TUBE DE CUIVRE DE UNPLA
TED CONNECTE STUB
AVEC ETEINT
(P
AR
LES
AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU MUR
B = RECOMMENDED LOCA
TION FOR W
ASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM W
ALL
UBICACIÓN RECOMENDADA
P
ARA
EL
DRENAJE DE SALIDA
DE
AGUA, DE 1-1/2” DE DIÁMETRO.
El
TALONARIO 2 FUERA
DE P
ARED
EMPLACEMENT
RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2” DE SOR
TIE D’EAU.
STUB 2 HORS DU MUR
C = 1-1/4” TRAP
NOT FURNISHED
PURGADOR DE 1-1/4” NO PROPORCIONADO SIPHON 1-1/4” NON FOURNI
LEGEND/LEYENDA/LÉGENDE D = ELECTRICAL
SUPPL
Y (3) WIRE RECESSED BOX DUPLEX OUTLET**
SUMINISTRO ELÉCTRICO (3) CAJA
ENCHUFE DE
ALAMBRE SALIDA
DÚPLEX
ALIMENT
ATION ÉLECTRIQUE (3) BOÎTIER ENCASTRÉ
E = INSURE PROPER VENTILA
TION BY
MAINT
AINING 6” (152
mm
) (MIN.) CLEARANCE FROM CABINET LOUVERS T
O W
ALL.
ASEGURE UNA
VENTILACIÓN
ADECUADA
MANTENIENDO UN ESP
ACIO E 6” (152
mm
) (MÍN.) DE HOLGURA
ENTRE LA
REJILLA
DE VENTILACIÓN DEL
MUEBLE
Y LA
P
ARED.
ASSUREZ-VOUS UNE BONNE VENTILA
TION EN GARDANT
6” (152
mm
) (MIN.) ENTRE LES ÉVENTS DE L
’ENCEINTE ET
LE MUR.
F = 7/16 BOL
T HOLES FOR F
ASTENING UNIT T
O W
ALL
AGUJEROS DE LAS
TUERCAS DE 7/16 P
ARA
SUJET
AR LA
UNIDAD
A LA
P
ARED
TROUS D’ÉCROUS 7/16 POUR FIXER L
’APP
AREIL
AU MUR
**NEW INST
ALLA
TIONS MUST USE GROUND F
AUL
T CIRCUIT INTERRUPTER (GFCI)
**
Las nuevas instalaciones deben utilizar el interruptor de circuito de tierra de la avería (GFCI)
**
Les nouvelles installations doivent employer l’interrupteur de circuit moulu de défaut (GFCI)
*