background image

Page 2

98768C  (Rev. A - 6/11)

HVRGRN8WSNF*1B   HVRGRN8BLWSNF*1B

C L

31

 1

3

/1

6"

80

8m

m

RI

M

HE

IG

H

T

12

 5

/16

"

31

3m

m

6 3/

4

"

17

1m

m

27

"

68

6m

m

*

6 1

/4

"

15

8m

m

1

 1/

2"

38

m

m

8" 20

3

m

m

2 5/

8

"

66

m

m

3 9/

1

6

"

90

m

m

19

 1/

1

6

"

48

4m

m

18

 5

/8"

47

3

m

m

32

 1

5

/1

6"

83

7

m

m

ORI

F

IC

E

HE

IG

H

T

HA

N

G

E

R

 B

R

AC

KE

T

C

7" 17

8

m

m

7" 17

8m

m

17

 7

/8"

45

4

m

m

1 3

/8

"

35

m

m

1

 3/

8"

35

mm

5 3

/4"

1

46m

m

5 3/

4

"

14

6m

m

15

"

38

1

m

m

O

5/

1

6

"

8m

m

HO

L

E

S

 (5

 PL

)

7

/16

" X

 3/

4

"

(1

1

m

m

 X

 1

9

m

m

)

OB

R

O

U

N

D

M

O

UNT

IN

G

HO

LE

S (

6

 P

L

)

3 3

/8

"

86

m

m

13

 1

3

/1

6"

35

1

m

m

2 9

/1

6

"

65

m

m

7 1

/4

"

1

85m

m

4

 9/

16

"

11

6m

m

2

 1/

2"

64

m

m

11

/1

6"

18

m

m

2 7

/1

6

"

63

m

m

3 1

/2

"

89

m

m

4 1/

2

"

11

4m

m

5" 12

7m

m

9

 15

/1

6"

25

2

m

m

A

D

B

E

E

F

18

 3/

8"

46

7m

m

21

 3/

8

"

5

43m

m

25

"

63

5

m

m

30

 1

5

/1

6"

78

6

m

m

51

 9

/16

"

13

10

m

m

Single Rough-In

Fig. 1

HTHB-HVRGRN-NF

REDUCE HEIGHT BY

 3” FOR INST

ALLA

TION OF

 CHILDRENS 

ADA

 COOLER

LEGEND:

A

 = RECOMMENDED W

A

TER SUPPL

Y

 LOCA

TION 3/8” O.D. UNPLA

TED COPPER 

TUBE CONNECT

 STUB 1-1/2” (38mm)

       OUT

 FROM W

ALL.  SHUT

 OFF V

A

L

VE NOT

 FURNISHED.

B = RECOMMENDED LOCA

TION FOR W

ASTE OUTLET

 1-1/4” O.D. DRAIN.

C = 1-1/4” TRAP NOT FURNISHED.

D = ELECTRICAL

 SUPPL

Y

 (3) WIRE RECESSED BOX, DUPLEX OUTLET

 REQUIRED.

E = INSURE PROPER VENTILA

TION BY

 MAINT

AINING 6” (152mm) MIN. CLEARANCE FROM CABINET

 LOUVER 

T

O

 W

ALL.

F = 7/16” BOL

T

 HOLES FOR F

ASTENING UNITS 

T

O

 W

ALL.

FINISHED FLOOR

Содержание HVRGRN8WSNF 1B Series

Страница 1: ...ICAL EQUIPMENT SUCHAS TELEPHONE COMPUTERS ETC TO WATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICALFEEDBACK INTOAFOUNTAIN CREATINGAN ELEC TROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED ANY DRAIN FITTING...

Страница 2: ... 11 16 18mm 2 7 16 63mm 3 1 2 89mm 4 1 2 114mm 5 127mm 9 15 16 252mm A D B E E F 18 3 8 467mm 21 3 8 543mm 25 635mm 30 15 16 786mm 51 9 16 1310mm Single Rough In Fig 1 HTHB HVRGRN NF REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDRENS ADA COOLER LEGEND A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 38mm OUT FROM WALL SHUT OFF VALVE NOT FURNISHED B RECOMMENDED LOCA...

Страница 3: ...m 4 1 2 114mm 3 1 2 89mm 6 1 4 159mm FINISHED FLOOR 13 13 16 351mm 18 3 4 477mm 20 1 8 511mm 25 1 8 638mm 8 203mm 6 3 4 171mm 12 5 16 313mm 6 1 2 165mm 27 686mm 31 13 16 809mm RIM HEIGHT 32 15 16 837mm ORIFICE HEIGHT Two Level Rough In Fig 2 HTHB HVRGRNBL NF REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDRENS ADA COOLER LEGEND A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT S...

Страница 4: ...ower cord and waterline through the hole on top of water cooler NOTE To prevent scratching the basin place a towel or soft cloth over the entire basin when working above it 8 With the power cord and waterline through hole on top of water cooler place Bottle Filler on the three 3 angled tabs protruding from the wall mounting plate installed on wall See Fig 3 Make sure rubber Drain Mat is installed ...

Страница 5: ...ow be illuminated indicating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR 1 Depress the program button for approximately 2 seconds until the display changes then release The display will change and scroll through three messages RST FLTR Reset Filter Status LED RST BCNT Reset Bottle Count RNG SET Range Set for IR Sensor 2 If the program button is not pushed again the...

Страница 6: ...ected allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button for approximately 2 seconds until the display changes then release The display will change and scroll through two messages RST FLTR Reset Fi...

Страница 7: ... install the four screws as shown in Fig 8 2 It is recommended that the cover be removed and the drain cover be cleaned weekly To dis assemble or re assemble the drain cover the mat can be picked up from the front to access the screws beneath WALL MOUNTING PLATE Fig 8 PRINTED IN U S A FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW HALSEYTAYLOR COM PARA PIEZAS DE REEMPLAZO PÓNGAS...