INSTALLATION INSTRUCTIONS

1. This fountain is to be mounted on a smooth, flat, finished wall surface, with adequate support structure.

2. Establish rim height fountain is to be mounted at.

3. Refer to rough-in for plumbing.

4. Locate and install trap (not included).

5. Install shut-off valve (not included) on building water supply.

6. Secure fountain using 1/4" (6mm) lag screws or bolts (not included).

CAUTION:

 This fountain is rated for inlet water pressure of 20-90 psi. Should the inlet water supply

exceed 90 psi, a pressure reducing regulator should be used.

7. Connect fountain to building supply line by running a water line between the shut-off valve and fountain.

8. Turn on water supply and check all connections for leaks.

9. Adjust bubbler stream height. (See instructions below)

TROUBLE SHOOTING & MAINTENANCE

PROJECTOR:

 If mineral deposits build up in the orifice, they can be

removed by using a round file or small diameter wire.

CAUTION: 

Care must be taken not to damage orifice assembly.

STREAM REGULATOR: 

Stream height is factory set at 45-50 psi.

If supply pressure varies greatly from this, remove the

cap from the bubbler assembly/valve regulator and

adjust the screw on the regulator. Clockwise adjustment

will raise stream height and counterclockwise will lower

stream height. A stream height of 1-1/2" (38mm) is

recommended. (See Fig. 1)

FIG. 1