Description

The 

S40

Stop is a robust, heavy duty, safety switch unit. When properly installed, 

it provides safe access and control for a variety of machinery. This unit may be in-

stalled in any orientation. The unit is ready to accept a variety of modules from the 

amGard

S40

 range, which will enable it to be used in many applications. Safety 

switch interlock for use in 

S40 

range.

• Dual force break normally closed safety circuits. 

• Single normally open monitor contact. 

• LED status indication.

• PLe.

• Stainless steel construction.

• IP69K.

Note:

 If, as a result of risk assessment, it cannot be discounted that persons can be enclosed within a danger zone, then 

guard locks with additional removable keys (safety keys) must be used or comparable measures must be taken - GS ET 19.

Options & Ordering Information

Description

Control Voltage

Part No.

Standard

24V AC/DC

S40ST401

Standard

110V AC

S40ST101

Standard

230V AC

S40ST201

Important:

This product is designed for use according to the installation and operating instructions enclosed. It must be installed 

by competent and qualified personnel who have read and understood the whole of this document prior to commencing 

installation. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment 

may be impaired. Any modification to or deviation from these instructions invalidates all warranties. Fortress Interlocks Ltd 

accepts no liability whatsoever for any situation arising from misuse or misapplication of this product. This product is not to 

be used as a Mains Isolator or Emergency Stop. The unit is a component to be added to a permanent electrical installation 

meeting the requirements of the applicable IEC/EN standards. This product meets the requirements of the standard EN ISO 

14119 – Safety of machinery, interlocking devices associated with guards. Principles for design and selection.

The voltages used within the 

S40

Stop circuits must all be of the same type. i.e. ALL Hazardous Live or ALL Machine 

Extra Low Voltage. 

Note: The availability of spare Actuators and Keys makes it possible to easily bypass the safety devices and, for 

this reason, the security of any spare Actuators and Keys must be effectively monitored. Where applicable, the 

same also applies for Keys used for resetting after an Escape Release or Manual Override. 

BEWARE OF INTENTIONAL MISUSE CAUSED BY OPERATORS WANTING TO BYPASS SAFETY SYSTEMS. THE 

INSTALLER SHOULD ASSESS THE RISKS AND MITIGATE AGAINST THEM. 

IF YOU HAVE ANY QUESTIONS OR QUERIES OF ANY NATURE WHATSOEVER PLEASE CONTACT THE SUPPLIER 

WHO WILL BE PLEASED TO ADVISE AND ASSIST.