Appendices 

January 2023 

• 

Rev. 0 

• Standard Devices User Manual

 43

Gas List by Number

To use any of these gases in your device, use Gas Select™ 

(

page 23

).

#

Short 

Name

Long 

Name

0

Air

Air (Clean Dry)

1

Ar

Argon

2

CH

4

Methane

3

CO

Carbon Monoxide

4

CO

2

Carbon Dioxide

5

C

2

H

6

Ethane

6

H

2

Hydrogen

7

He 

Helium

8

N

2

Nitrogen

9

N

2

O

Nitrous Oxide

10

Ne

Neon

11

O

2

Oxygen

12

C

3

H

8

Propane

13

nC

4

H

10

Normal Butane

14

C

2

H

2

Acetylene

15

C

2

H

4

Ethylene (Ethene)

16

iC

4

H

10

Isobutane

17

Kr

Krypton

18

Xe

Xenon

19

SF

6

Sulfur Hexafluoride

1

20

C-25

25% CO2, 75% Ar

21

C-10

10% CO2, 90% Ar

22

C-8

8% CO2, 92% Ar

23

C-2

2% CO2, 98% Ar

24

C-75

75% CO2, 25% Ar

25

He-25

25% He, 75% Ar

26

He-75

75% He, 25% Ar

27

A1025

90% He, 7.5% Ar, 2.5% CO2

28

Star29

Stargon CS (90% Ar, 

8% CO2, 2% O2)

29

P-5

5% CH4, 95% Ar

30

NO

Nitric Oxide

2

31

NF

3

Nitrogen Trifluoride

2

32

NH

3

Ammonia

2

33

Cl

2

Chlorine

2

34

H

2

S

Hydrogen Sulfide

2

35

SO

2

Sulfur Dioxide

2

36

C

3

H

6

Propylene

2

80

1Buten

1-Butylene

2

81

cButen

Cis-Butene (cis-2-Butene)

2

82

iButen

Isobutene

2

83

tButen

Trans-2-Butene

2

84

COS

Carbonyl Sulfide

2

85

DME

Dimethylether (C2H6O)

2

86

SiH

4

Silane

2

100

R-11

Trichlorofluoromethane (CCl3F)

2

,

³

101

R-115

Chloropentafluoroethane 

(C2ClF5)

2

,

³

#

Short 

Name

Long 

Name

102

R-116

Hexafluoroethane (C2F6)

2

103

R-124

Chlorotetrafluoroethane 

(C2HClF4)

2

,

³

104

R-125

Pentafluoroethane (CF3CHF2)

2

,

³

105

R-134A

Tetrafluoroethane (CH2FCF3)

2

,

³

106

R-14

Tetrafluoromethane (CF4)

2

107

R-142b

Chlorodifluoroethane 

(CH3CClF2)

2

,

³

108

R-143a

Trifluoroethane (C2H3F3)

2

,

³

109

R-152a

Difluoroethane (C2H4F2)

2

110

R-22

Difluoromonochloromethane 

(CHClF2)

2

,

³

111

R-23

Trifluoromethane (CHF3)

2

,

³

112

R-32

Difluoromethane (CH2F2)

2

,

³

113

R-318

Octafluorocyclobutane (C4F8)

2

114

R-404A

44% R-125, 4% R-134A, 

52% R-143A

2

,

³

115

R-407C

23% R-32, 25% R-125, 

52% R-143A

2

,

³

116

R-410A

50% R-32, 50% R-125

2

,

³

117

R-507A

50% R-125, 50% R-143A

2

,

³

140

C-15

15% CO2, 85% Ar

141

C-20

20% CO2, 80% Ar

142

C-50

50% CO2, 50% Ar

143

He-50

50% He, 50% Ar

144

He-90

90% He, 10% Ar

145

Bio5M

5% CH4, 95% CO2

146

Bio10M

10% CH4, 90% CO2

147

Bio15M

15% CH4, 85% CO2

148

Bio20M

20% CH4, 80% CO2

149

Bio25M

25% CH4, 75% CO2

150

Bio30M

30% CH4, 70% CO2

151

Bio35M

35% CH4, 65% CO2

152

Bio40M

40% CH4, 60% CO2

153

Bio45M

45% CH4, 55% CO2

154

Bio50M

50% CH4, 50% CO2

155

Bio55M

55% CH4, 45% CO2

156

Bio60M

60% CH4, 40% CO2

157

Bio65M

65% CH4, 35% CO2

158

Bio70M

70% CH4, 30% CO2

159

Bio75M

75% CH4, 25% CO2

160

Bio80M

80% CH4, 20% CO2

161

Bio85M

85% CH4, 15% CO2

162

Bio90M

90% CH4, 10% CO2

163

Bio95M

95% CH4, 5% CO2

164

EAN-32

32% O2, 68% N2

165

EAN-36

36% O2, 64% N2

166

EAN-40

40% O2, 60% N2

167

HeOx20

20% O2, 80% He

168

HeOx21

21% O2, 79% He

169

HeOx30

30% O2, 70% He

170

HeOx40

40% O2, 60% He

171

HeOx50

50% O2, 50% He

172

HeOx60

60% O2, 40% He

173

HeOx80

80% O2, 20% He

174

HeOx99

99% O2, 1% He

#

Short 

Name

Long 

Name

175

EA-40

Enriched Air-40% O2

176

EA-60

Enriched Air-60% O2

177

EA-80

Enriched Air-80% O2

178

Metab

Metabolic Exhalant (16% O2, 

78.04% N2, 5% CO2, 0.96% Ar)

179

LG-4.5

4.5% CO2, 13.5% N2, 82% He

180

LG-6

6% CO2, 14% N2, 80% He

181

LG-7

7% CO2, 14% N2, 79% He

182

LG-9

9% CO2, 15% N2, 76% He

183

HeNe-9

9% Ne, 91% He

184

LG-9.4

9.4% CO2, 19.25% N2, 71.35% He

185

SynG-1

40% H2, 29% CO, 20% 

CO2, 11% CH4

186

SynG-2

64% H2, 28% CO, 1% 

CO2, 7% CH4

187

SynG-3

70% H2, 4% CO, 25% 

CO2, 1% CH4

188

SynG-4

83% H2, 14% CO, 3% CH4

189

NatG-1

93% CH4, 3% C2H6, 1% 

C3H8, 2% N2, 1% CO2

190

NatG-2

95% CH4, 3% C2H6, 

1% N2, 1% CO2

191

NatG-3

95.2% CH4, 2.5% C2H6, 

0.2% C3H8, 0.1% C4H10, 

1.3% N2, 0.7% CO2

192

CoalG

50% H2, 35% CH4, 

10% CO, 5% C2H4

193

Endo

75% H2, 25% N2

194

HHO

66.67% H2, 33.33% O2

195

HD-5

LPG: 96.1% C3H8, 1.5% C2H6, 

0.4% C3H6, 1.9% n-C4H10

196

HD-10

LPG: 85% C3H8, 10% 

C3H6, 5% n-C4H10

197

OCG-89

89% O2, 7% N2, 4% Ar

198

OCG-93

93% O2, 3% N2, 4% Ar

199

OCG-95

95% O2, 1% N2, 4% Ar

200

FG-1

2.5% O2, 10.8% CO2, 

85.7% N2, 1% Ar

201

FG-2

2.9% O2, 14% CO2, 

82.1% N2, 1% Ar

202

FG-3

3.7% O2, 15% CO2, 

80.3% N2, 1% Ar

203

FG-4

7% O2, 12% CO2, 80% N2, 1% Ar

204

FG-5

10% O2, 9.5% CO2, 

79.5% N2, 1% Ar

205

FG-6

13% O2, 7% CO2, 79% N2, 1% Ar

206

P-10

10% CH4 90% Ar

210

D-2

Deuterium

Sulfur hexafluoride is a highly potent greenhouse 

gas monitored under the Kyoto Protocol.

2

 

Corrosive-resistant units only

3

 

Under the Montreal Protocol and Kigali Amendment, the 

production and consumption of these ozone-depleting 

substances (ODS) is being or has been phased out. 

It is recommended you ensure compliance with this 

universally ratified treaty before attempting to use 

these gases, in addition to R113, R-123, and R-141b.

Содержание ALICAT SCIENTIFIC M Series

Страница 1: ...OPERATING MANUAL FOR STANDARD FLOW AND PRESSURE DEVICES Models M MC P PC L LC...

Страница 2: ...d the Limited Lifetime Warranty Fill out the Service Request Form at alicat com service or contact us directly when it is time to send in your device for recalibration For devices ordered with CSA ATE...

Страница 3: ...rol Loop 20 Controlled Variable 20 PD PDF or PD I Control Algorithms 21 Flow Limit while Controlling Pressure Flow Controllers 21 Control Deadband for Pressure Control 22 Device Setup 23 Gas Selection...

Страница 4: ...7 Maintenance 38 Cleaning 38 Repair 38 Recalibration 38 Appendix A Pinouts 39 8 Pin Mini DIN Default 39 Locking Industrial Connector Pinout 39 9 Pin D Sub Connector Common Pinouts 40 15 Pin D Sub Conn...

Страница 5: ...ight page 11 Change your STP to match any standard temperature and pressure reference for your mass flow page 25 Log data to your PC with a serial data connection to control the device and capture dat...

Страница 6: ...SETUP Sensor Totalizer 1 or Totalizer 2 See page 25 Connectors and Buttons The drawing to the right represents a typical configuration of a standard controller Your device s appearance and connection...

Страница 7: ...and process connection if present For pressure controllers refer to Appendix C page 45 for diagrams on plumbing specific controllers Face seal fittings do not need Teflon tape applied to the threads...

Страница 8: ...5 12 Vdc Output as the standard 0 5 Vdc analog output signal Pin 2 is normally a constant 5 12 Vdc Controller 8 Pin Mini DIN Pinout Meter and Gauge 8 Pin Mini DIN Pinout Pin Function Pin Function 1 No...

Страница 9: ...r gauge remotely by momentarily grounding pin 4 When the switch is closed the device tares Operation resumes when the switch is released You can also tare with the front controls page 12 or serial com...

Страница 10: ...the upstream bleed port screw 1 to 2 turns or until liquid begins to leak from the threads Do not remove the screw as it has pressure behind it is very small easy to lose and delicate to rethread 2 G...

Страница 11: ...se button 5 Pressure and liquid devices do not measure mass flow Highlight temperature mass flow and liquid devices use button 2 Pressure devices do not measure temperature Changing the setpoint contr...

Страница 12: ...W BEFORE PRESSING TARE may display on some devices If so press TARE to confirm taring the flow Taring Pressure TARE PRESS or MENU TARES TARE PRESS Taring pressure requires the device to be open to atm...

Страница 13: ...anti corrosive line of mass flow devices As soon as you press SET from the gas list your device reconfigures its flow rate calculations to the newly selected gas properties There is no need to restart...

Страница 14: ...17 for setpoint instructions NEXT moves to the totalizer screen if enabled or MENU opens the device menu Totalizer Screens Flow Devices MENU SETUP Sensor Totalizer Totalizer 1 or Totalizer 2 Mass flow...

Страница 15: ...tions RED Parameters are displayed in red when its value exceeds 128 of the device s specifications YELLOW Menu items that are ready to be selected appear in yellow The color replaces the symbol in se...

Страница 16: ...Initials of the person who calibrated the device SW Firmware version Device Full Scale Ranges MENU ABOUT Full Scale Ranges This displays the maximum calibrated range of available flow and pressure re...

Страница 17: ...e taring Delay Before Tare manages how much time the controller waits before taring Make sure the delay provides enough time for the process to stop flow and settle Caution Auto tare typically is not...

Страница 18: ...tpoint Limits The setpoint limits menu configures upper and lower limits for selecting a setpoint By default the limits are the controller s measuring range but more strict limits may be beneficial in...

Страница 19: ...t volume of gas flows through the controller the valve closes and flow stops You can repeat batches with a single button press To utilize batching at least one totalizer must be enabled The BATCH butt...

Страница 20: ...n the main display and or as part of transmitted serial data There are four valve display options None No valve information is displayed Main Screen Only on the main display Digital Data Only in the s...

Страница 21: ...ill predict needed future corrections based on the current rate of change in the system This often results in slowing the system down to minimize overshoot and oscillations Troubleshooting Valve Perfo...

Страница 22: ...OL Control Deadband Deadband The controller must first reach the setpoint for the deadband to engage If the process variable drifts outside a deadband limit active control resumes until the setpoint i...

Страница 23: ...erties and exits to the setup menu COMPOSER Gas Mixes MENU SETUP Active Gas COMPOSER Mixes To remain accurate your mass flow device needs to reference the viscosity of the gas you are flowing through...

Страница 24: ...a second page use the PAGE button to see the remaining list Viewing Deleting and Creating Similar Mixes MENU SETUP Active Gas COMPOSER Mixes Select mix INFO The current configuration of any existing C...

Страница 25: ...troller with a zero band value of 0 25 displays as 0 SLPM for all readings below 0 05 SLPM This function also applies to gauge pressure readings when using the optional barometer Totalizer Options Flo...

Страница 26: ...lizer Digital Data MENU SETUP Sensor Totalizer Totalizer 1 or Totalizer 2 Digital Data This setting enables the device to report the totalizer value whenever it is polled by the serial terminal page 2...

Страница 27: ...d can be set in seconds up to 99999 9 seconds 1 day 3 hours 46 minutes 39 9 seconds Baud Rate SETUP RS 232 Serial or RS 485 Serial Baud Rate Baud rate is the speed at which digital devices transfer in...

Страница 28: ...will be on when the device powers on On color displays press LESS BRIGHT or BRIGHTER to adjust the brightness level Display Rotation MENU SETUP Display Display Rotation The device has the option of in...

Страница 29: ...l Alicat devices Within its features is a terminal that allows for direct serial communication with connected devices Flowvision 2 0 can be downloaded along with its user manual from alicat com flowvi...

Страница 30: ...nual taring can be accomplished through two separate commands for flow and pressure Taring flow sets the zero flow reading and must be done when no flow is passing through the device Tare flow unit_id...

Страница 31: ...POSER gas mixes have a mix number between 236 and 255 Choose a user mix unit_idGGas Number Example AG255 reconfigures for user mix 255 Defining a new COMPOSER gas mix is faster using serial commands t...

Страница 32: ...red_unit_id Set streaming interval unit_idNCS number_of_ms Query live data info unit_id D Manufacturer info unit_id M Firmware version unit_idve Lock the front display unit_idL Unlock the display unit...

Страница 33: ...RTU Serial Protocol Alicat uses the Modbus standard of offsetting registers by 1 from addresses meaning register 1 is equivalent to address 0 However some systems expect data to be mapped as 0 indexed...

Страница 34: ...send a command to register 1000 without sending an argument to 1001 the device will interpret the command with a default argument of 0 At any time after sending a special command to registers 1000 10...

Страница 35: ...Controllers 0 65535 10 Change I in PID Loop 0 Mass Flow Controllers 1 Mass Flow and Liquid Controllers 2 PSID Controllers 3 Abs Press Controllers and Mass Flow Controllers 4 Gauge Pressure Controller...

Страница 36: ...ering Units From this menu you can adjust any variable s units For more information see page 24 Issue My controller won t reach its setpoint Action This is often caused by not enough supply pressure i...

Страница 37: ...o check before changing gases or liquids is the chemical and material compatibility of the gas being used with the wetted materials inside the controller We also recommend contac ting suppor t page 2...

Страница 38: ...device can be cleaned with a soft dry cloth Warning If you suspect that debris or other foreign material has entered your device do not take apart the flow body to clean it Please contact support for...

Страница 39: ...Serial RS 232 RX RS 485 Input Signal receive 3 Serial RS 232 RX RS 485 Input Signal receive 4 Analog Setpoint Input Controllers Remote Tare Meters and Gauges 4 Analog Setpoint Input Controllers Remot...

Страница 40: ...log Out RX or A Analog Out NC Analog Out 3 Ground Analog In NC NC NC Ground NC 4 NC Ground NC NC NC Analog Out NC 5 Power In Ground Power In Ground Ground Power In Ground 6 NC Ground NC Analog Out NC...

Страница 41: ...t Input Controllers Ground to Tare Meters and Gauges Analog Setpoint Input Controllers Ground to Tare Meters and Gauges 5 Serial RS 232TX RS 485 output signal send Serial RS 232TX RS 485 output signal...

Страница 42: ...r L s SL s NL s Liter per second LPM SLPM NLPM Liter per minute L h SL h NL h Liter per hour US GPM US gallon per minute US GPH US gallon per hour CCS SCCS NCCS Cubic centimeter per second CCM SCCM NC...

Страница 43: ...2 150 Bio30M 30 CH4 70 CO2 151 Bio35M 35 CH4 65 CO2 152 Bio40M 40 CH4 60 CO2 153 Bio45M 45 CH4 55 CO2 154 Bio50M 50 CH4 50 CO2 155 Bio55M 55 CH4 45 CO2 156 Bio60M 60 CH4 40 CO2 157 Bio65M 65 CH4 35 CO...

Страница 44: ...Deuterium D2 Ethane C2H6 Ethylene Ethene C2H4 Helium He Hydrogen H2 Krypton Kr Methane CH4 Neon Ne Nitrogen N2 Nitrous Oxide N2O Oxygen O2 Propane C3H8 Sulfur Hexafluoride SF6 1 Xenon Xe Breathing Gas...

Страница 45: ...lenoid is energized pressure is delivered to the shutoff valve causing it to open When the solenoid is returned to a relaxed state the gas vents to atmosphere allowing the shut off valve to close Pres...

Страница 46: ...re Differential Pressure Control Differential pressure controllers have two ports for connecting to points in the system where the differential pressure is measured The upstream port is for the higher...

Страница 47: ...menus available on the screen Integration of the vacuum sensor control valve and PID algorithm in a single device eliminates the need for an external vacuum sensor and throttle valve in your system T...

Отзывы: