Installation Guide 

and Users Manual

Island Mount Range Hood

168/198 Series Island Mount Range Hood

IMPORTANT:

Read and save these instructions.

NOTICE:

Installer:

 Leave this guide with the homeowner

Homeowner:

 Keep this guide for future reference

Rev. 2016u.6a

Suitable for:

Standard Class 

“R” Class

“E” Class

“SP” Class

Содержание SV198 Series

Страница 1: ...Hood 168 198 Series Island Mount Range Hood IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference Rev 2016u 6a...

Страница 2: ......

Страница 3: ...ities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce...

Страница 4: ...o out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use a...

Страница 5: ...ing requirements 5 Mount heights clearance 5 6 Calculating vent system length 6 Venting methods ductless conversion 7 Charcoal filters electrical requirements 8 Preparation 9 Installation 10 12 Range...

Страница 6: ...Head Screw 18 Pcs 4mm x 16mm Phillips Head Tapping Screw 24 Pcs 4mm x 8mm Phillips Head Tapping Screw 16 Pcs Optional 4mm x 8mm Phillips Head Tapping Screw for Air Diverter 4 Pcs Optional Phillips He...

Страница 7: ...oun 2 tertop stove recommend 28 to 31 Distance between the countertop stove 3 to the range hood Height of hood and duct cover 4 For the most efficient quiet operation A distance of 28 to 31 is recomme...

Страница 8: ...tove top to hood bottom should be no higher than 31 inch It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods...

Страница 9: ...conversion is intended for applications where an exhaust duct work is not possible to be installed When converted the hood functions as a purifying hood rather than an exhaust hood Fumes and exhaust...

Страница 10: ...be connected with copper wire plug only Always use plug provided If not possible connect three wires ac cording to its color black to Hot white to Neutral and green to Ground to house wires and cap w...

Страница 11: ...e make sure that the support system or framework being used is 2 stable and secure in the ceiling Put a thick protective covering over counter top cook top or range to protect from damage or dirt Remo...

Страница 12: ...behind the sheet rock for best weight support Concrete ceiling Use concrete sleeve anchor Place support frames inside the top support plate adjust 2 support frames to length required and lock the supp...

Страница 13: ...make sure all joints are secured and air tight Figure 5 Figure 4A Figure 4C Figure 4B Slide both chimneys upward Recirculating Non Vented Kit If Re Circulating Kit is not purchased skip this step Plac...

Страница 14: ...wly slide down both chimneys until they sit on the hood Connect the duct work and connect the power cable see figure 7A Bring only the upper chimney up until it reaches the ceiling secure it with two...

Страница 15: ...ed mode will cancel Press the Light Switch to power on the lights CAUTION DO NOT touch the lights until switched OFFand cooled Turn Off Press the Power Switch to turn off the power Press the Light Swi...

Страница 16: ...e timer then flash for three seconds While flashing the timer can be adjusted by 1 minute increments with the default set at 15 minutes from as short as 1 minute to as long as 99 minutes After the des...

Страница 17: ...operating press the button once the Speed Timer Indicator will display a 15 minute timer then flash for three seconds While flashing the timer can be adjusted by 1 minute increments by pressing button...

Страница 18: ...Page 16 Range Hood Operations Wiring Diagram Continued SV168 198 Series R Class Wiring Diagram NOTE Wiring Diagrams shown above with GU10 light configuration A transformer is required for MR16 Lights...

Страница 19: ...ime reached 30 hours then the Cleaning Reminder Indicator C flashes and reminds user to clean the aluminum filter After cleaning the filter and when the motor is not in use press and hold Increase Val...

Страница 20: ...nce to turn on the lights and once again to turn off the lights While the lights are off press and hold Light button for over 3 seconds to dim the lights from high to low Level of brightness will be s...

Страница 21: ...s Wiring Diagram Continued SV168 198 Series E Class Wiring Diagram 4 Speed NOTE Wiring Diagrams shown above with GU10 light configuration A transformer is required for MR16 Lights SV168 198 Series E C...

Страница 22: ...cir cular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all...

Страница 23: ...ce Without these components operating blowers could catch on to hair fingers and loose clothing NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers NEVER leave cooki...

Страница 24: ...face and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals...

Страница 25: ...lb by pulling in the direction of wavy arrow Do not touch the new light bulb with bare hands Reverse the steps to install a new halogen light bulb Turn ON breaker and range hood to test for operation...

Страница 26: ...s unplugged or turn OFF breaker Make sure the lights are cool to touch carefully align the arrow on the inner ring with the arrow on the outer ring where it says OPEN with the Inner Ring Opener as sho...

Страница 27: ...sumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner produ...

Страница 28: ...ng fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Ap...

Страница 29: ...Page 27 Your Notes...

Страница 30: ...Your Notes Page 28...

Страница 31: ...Your Notes Page 29...

Страница 32: ...Aus Tex Appliance 113 Industrial Blvd D Austin TX 78745 Tel 512 444 2775...