Halkey-Roberts Pro 1F V95000 Скачать руководство пользователя страница 1

C02 CYLINDER

STEP 2.

CAP

STEP 3.

HOUSING

STEP 6.

HOUSING 

SHOULDER

STEP 7.

SERVICE

INDICATOR

STEP 10.

BOBBIN

STEP 4.

               

DISASSEMBLY

                             (see figure)

Step 1

:    Unpack or open the life vest so that the manual/automatic inflator 

is visible.

Step 2

:   Remove gas CO2 cylinder by rotating cylinder couterclockwise then 

pull out.  

Discard cylinder.

               

Step 3

:    Remove cap by turning counter-clockwise.

Step 4

:    Remove bobbin from cap or housing unit.  

Discard bobbin

 

(yellow).  Check the housing to be sure it is clear and dry.

Note:   The bobbin (yellow) body may remain in the housing or in the cap 

assembly when you remove the cap.  The bobbin body must be removed prior 

to Rearming.

REARMING

          

Note:   Rearming must follow the

 

sequence below

.

Step 5

:   A new bobbin must be used.  New bobbin must have been 

purchased

within three ( 3 ) years. If bobbin purchase date is unknown, check date on 

bobbin, replace if over three (3) years.

Step 6

:                      

IMPORTANT

!

Bobbin (yellow) must be installed into the HOUSING  (**see figure), white 

side up, aligning the slots on the bobbin with the ridges inside the threaded 

housing.  The bobbin will slide in easily if installed correctly.

Step 7

:    Install cap by screwing clockwise until it meets the housing 

shoulder.

Note:  No gap between the cap and the housing shoulder.

Step 8

:   Check the new cylinder to be sure it has not been punctured.

 

                              

IMPORTANT

!

Install the bobbin and cap before installing a new cylinder.

Step 9

:   Install new cylinder by engaging the cylinder threads with the 

inflator threads. Turn cylinder clockwise till a firm seal is achieved.                

           WARNING: PFD WILL ONLY INFLATE IF

               CYLINDER IS TURNED TO FULL STOP.

Step 10

: Check to be sure service indicator is 

GREEN.

Halkey-Roberts Pro 1F® V95000 

Service Instructions

SERVICE INDICATOR

If green, unit is 

operable.

If red, stop and 

service unit.