Piranha Series 

Submersible Water Pump 

  

Operation Manual

 

Models: 

  

PN3000 

 PN4200 

 PN5500 

 PN6300  

Содержание Piranha Series

Страница 1: ...Piranha Series Submersible Water Pump Operation Manual Models PN3000 PN4200 PN5500 PN6300 ...

Страница 2: ...Piranha Series Flow Rate Chart PN3000 PN4200 PN5500 PN6300 PN3000 PN4200 PN5500 PN6300 ...

Страница 3: ... be either new or like new provided that it has functionality at least equal to that of the product being replaced No requests for service under this warranty will be accepted if received more than 30 days after the term of the warranty Correction of defects in the manner and for the duration of the warranty described in this warranty shall constitute complete fulfillment of all liabilities and re...

Страница 4: ... electrical shock DO NOT UNDER ANY CIRCUMSTANCE REMOVE THE GROUND PIN The 3 prong plug MUST be inserted into a compatible 3 prong grounded receptacle If the installation does not have such a receptacle it must be changed to the proper type wired and grounded in accordance with the National Electrical Code and all applicable local codes and ordinances The electrical supply must be a separate branch...

Страница 5: ...revent personal injury and equipment damage Situate pump in location with sufficient water level where water collects and flow readily If the pump is installed in a pump basin or pit the area must have sufficient space to allow amble of water circulation around the pump at all levels Basin or pit with at least 2 feet diameter is recommended furthermore it should be dimensioned according to the rel...

Страница 6: ...Dry operation may cause the pump motor to overheat and malfunction In dry operation or operation with lack of water cooling pump motor can become very hot do not come in contact with pump to avoid being burned Refer to Operating Water Level Make sure no extraneous objects such as pins nails or other metal objects are sucked into the pump In case of a power outage turn off the power to the pump to ...

Страница 7: ...indoors In certain conditions it is recommended that the pump be submerged in a bucket of water and stored at room temperature NOTE Always run a test operation before putting the pump back into service When the pump is left installed under water it should be run at regular intervals about once a week TROUBLESHOOTING WARNING FAILURE TO DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE HANDLING CAN CAU...

Страница 8: ...only and disassemble impeller from motor shaft to remove fibrous matters that wrap around the impeller Impeller is worn or damaged Inspect impeller replace as required Pump is air locked or inlet is exposed to air Shut off pump for approximately one minute then restart Repeat until air lock clears Do not operate the pump below the Minimum Water Level If air locking persist in a system with a check...