Operation
36
Section 3: Operating
Hale Products, Inc., May 2005, Rev-B
Figure 3-2: Pump Operator’s Panel
9.
Note the discharge and intake pressures, then gradually open the engine
throttle until the master discharge gauge indicates the desired pressure.
10.
Set the automatic relief valve according to your fire department policy, if so
equipped. If your fire department does not have a policy, see heading “TPM
Operation from a Hydrant” on page 37.
CAUTION !
DO NOT REDUCE THE PRESSURE ON THE INTAKE GAUGE BELOW DEPART-
MENT LIMITS. SERIOUS DAMAGE TO THE WATER MAIN COULD RESULT.
11.
If the master intake gauge shows a vacuum before the desired discharge
pressure or flow is achieved, you are receiving all the water that the suction
piping (hydrant) can supply.
12.
If you need to increase pressure when this occurs, pump flow must be
reduced or the water supply improved.
To increase pressure, reduce the pump flow. However, the master intake
gauge reading must be maintained at 5 PSI (0.34 BAR / 0.04 MPa),
minimum.
13.
As the throttle (engine speed) is increased, the pressure gauge reading
increases.
Содержание Silencer APS Series
Страница 6: ...Overview 6 Silencer Series Booster Pump p n 029 0020 83 0...
Страница 22: ...Introduction 22 Section 2 Introduction Hale Products Inc May 2006 Rev B...
Страница 32: ...Accessories Options 32 Section 2a Accessories Hale Products Inc May 2006 Rev B...
Страница 66: ...Preventive Maintenance 66 Silencer Series Booster Pump p n 029 0020 83 0...
Страница 124: ...Installation 124 Basic Installation Hale Products Inc August 06 Rev B...
Страница 143: ...143 Appendix F Cavitation Hale Products Inc Nov 2005 Rev A Cavitation...
Страница 144: ...Cavitation 144 Appendix F Cavitation Hale Products Inc Nov 2005 Rev A...