46
Maintenance and Care
5.4.5
Plug Connection Coding
The battery plugs of the machine, the
battery and the stationary charger unit
have to be coded according to the bat-
tery type and the nominal voltage with
coloured pins.
The charger unit’s plugs are/will be cod-
ed in the factory according to the char-
acteristics curve and changing the
characteristic curve (according to the
battery type ) always requires modifica-
tion of the plug coding.
Plug case of charger unit:
- grey for wet batteries
- green for maintenance-free Gel
batteries
Machine plug case:
- yellow for both battery types
Battery socket case:
- grey for wet batteries
- green for maintenance-free Gel
batterie
Remove the coding pin by pressing the
ends together by means of pliers.
Press together for assembly.
Insert pin such that the nominal voltage
inscription is visible through the case
window. Socket and plug always with
the same nominal voltage.
The following three requirements have
to be met:
1 Voltage coding is the same for all
plugs and socket
2 Coding pin colour in the machine =
yellow
3 Coding pin colour
Before first operation of the
machine, the batteries have to
be adequately charged by an
initial charging procedure.
Please observe the instruction
of the charger unit’s operating
manual.
Hako rejects any claim for war-
ranty on battery damges
caused by unfulfilled initial
charging.