17
No.
Symbol
Analysis
Treatment Method
1
【
】
【
】
Unable to reset after startup
1.
Determine it is no-load state in
startup;
2.
Make zero calibration again.
2
【
】
The weighed object is over full
range for 9 days
Reduce weight on weighing platform
3
【
】
The weighed object is below 0 for
5 days
Press
『
Zero
』
to reset
4
【
】
【
】
Out of zero clearing range
Check whether the weighing platform
has weight.
Remove weight.
5
【
】
Invalid operation
6
【
】
EEPROM checksum and error
Press
『
』
reprint factory value.
Start up again. If the information occurs
again, return to factory for repair.
Please calibrate the scale again if the
situation does not occur;
Attention:
this place is provided with all
parameters of instruments of the
factory.
7
【
】
The calibration input weight is too
small
Input ≥ 10 % weight of full range
8
【
】
The weight in calibration is too
light
Load ≥ 10 % weight of full range
9
【
】
The scale is dynamic in scale
Inspect the scale body
10
【
】
Setting error of date and time
Set according to specification of date
and time
11
【
】
Error of AD initialization
If the error occurs after restarting, return
it to the factory for repair
12
【
】
In loading scale, it indicates to
loading weight;
Load weight according to requirements;
13
【
】
It has entered menu setting
Press
『
』
to continue setting
14
【
】
End of zero point and loading
point calibration
15
【
】
Including current display weight in
accumulated value
16
【
】
Accumulated weight overflows
Clear accumulated weight in time
17
【
】
Loading default value
18
【
】
Printing
Appendix 1. Continuous Output Format Specification
1. Continuous output MT format
Continuous output MT format has 18 digits.
Содержание HAVA2500V
Страница 59: ...59 PARTS DRAWING OF THE old PUMPASSEMBLY 2020 01 01...
Страница 61: ...61 PARTS DRAWING OF THE new PUMP ASSEMBLY 2020 01 01...
Страница 64: ...64 PARTS DRAWING OF THE FRAME...