background image

Revised date: March 9, 2012 

3-2 Station Parts List (FX-951/FH-200) 

3-2 

Station Parts List 

No. 

Category 

Part name 

Specifications 

Product No. for each voltage 

100V 

110V 

120V 

220V 

230V 

240V 

Sales 

Front panel 

 

B2973 

Sales 

Button set 

 

B2982 

Sales 

P.W.B. for control 

For control and connector 

B3256 

Sales 

Case L 

With rubber feet/cushion 
rubber A 

(Refer to Photo 4-1-5 to 
4-1-7) 

B3255 

Sales 

Case R 

With rubber feet/cushion 
rubber B 

(Refer to Photo 4-1-5 to 
4-1-7) 

B2978 

Sales 

Transformer 

 

B2979 

B2983 

B2836 

B2984 

B2985 

B3067 

* The transformer 230V for Australian plug is B3067. 

Sales 

Power switch 

 

B2852 

Sales 

Fuse 

 

B2403(250V-2A)- 

B2987(250V-1A) 

Sales 

Power cord 

Rubber 2-pole grounding 

B2387 

Vinyl 2-pole grounding 

B2419 

Vinyl 3-conductor CH 
plug 

B2436 

Without vinyl 3-conductor 
plug 

B2421 

Molded BS plug 

B2422 

Molded BS plug CE 

 

 

 

 

B2425 

 

European plug 

B2424 

European plug CE 

 

 

 

B2424 

 

Australian plug 

B2426 

Sales 

Card 

 

B2972 

Sales 

Power receptacle 

 

B2666 

Sales 

Grounding plate 

 

B2227 

Sales 

Connecting cable 

 

B3253 

Sales 

Iron receptacle 

With screws 

B3001 

Sales 

Tip fixing spring 

 

B2791 

Sales 

Holder for iron 
receptacle 

 

B3248 

Sales 

Iron holder base 

With rubber feet 

B3251 

Sales 

Cleaning sponge 

 

A1536 

Sales 

Cleaner base 

With rubber feet 

B3249 

Sales 

Stay 

 

B3250 

Sales 

Switch case 
assembly 

 

B3252 

Sales 

Rubber feet 

Two feet for FX-951 
station 

(Refer to Photo 4-1-5 to 
4-1-7) 

B2016 

Содержание FH-200

Страница 1: ...onnector and Front Panel 4 3 Power Receptacle Power Switch and Transformer 4 4 Jack 4 5 Iron Holder Chapter 5 Wiring Diagram Warnings cautions and notes are placed at critical points in this manual to...

Страница 2: ...X 951 FH 200 Revision History Revision Date Information Revised Description Approved by Created by March 31 2007 First edition Hirai Nishii March 9 2012 3 2 Station Parts List Change the part number f...

Страница 3: ...tion Flow Chart Iron Holder Check Section 2 5 Checking the Power Supply Line Section 2 2 5 6 Checking the Power Supply Line Section 2 2 1 4 Checking the Interior Section 2 3 Voltage Application Check...

Страница 4: ...n and removal If the receptacle does not allow smooth insertion or removal Replace the P W B for control connector 4 Are the rubber feet of the case R and case L chipped or damaged If the rubber feet...

Страница 5: ...a resistance value is abnormal Replace the power cord 3 During measurement in step 2 above twist and bend the power cord at various angles including the plug and the station connecting part If abnorma...

Страница 6: ...istance on the primary side of the transformer as follows Measuring points Between the soldered parts of the power switch and the power receptacle on the primary side of the transformer If a resistanc...

Страница 7: ...ce faulty components If portions around the cracked or exploded components are burned Replace the whole P W B 3 Are the transformer and P W B for control connector correctly mounted If the parts are n...

Страница 8: ...k the sensor errors 1 Turn on the power switch 2 The following indications appear on the display in the order presented and the buzzer keeps beeping 3 Turn off the power switch If no indication appear...

Страница 9: ...ng temperature NOTE When the tip temperature reaches the setting temperature the buzzer will sound and the heater lamp at the lower right of the panel will start to flash 3 Insert a card Indicator Lef...

Страница 10: ...e beginning If the unit does not operate correctly The P W B is faulty Check the P W B using the procedure in step 7 6 Check the parameters 1 Turn off the power switch before inserting the card 2 If t...

Страница 11: ...etting and returns the unit to the normal operation If the unit does not operate correctly The P W B is faulty Check the P W B using the procedure in step 7 NOTE Perform the following inspection if th...

Страница 12: ...amaged Replenish or replace the rubber foot with a new one 2 There are 11 screws in total securing the iron holder Are any screws lost If lost Replenish the lost screw with a new one 3 Check whether t...

Страница 13: ...ance value is 4 7k 10 when the tip is released from the iron holder the unit conditions are normal If the resistance value is abnormal Replace the switch case assembly with a new one 5 Connect the con...

Страница 14: ...t Insulation test Apply 500VDC and check that the value is 25M or higher Withstanding voltage test Apply 1250VAC 1mA to check that it can resist for 1 second or longer NOTE Perform the following inspe...

Страница 15: ...First Edition March 31 2007 3 1 Exploded Drawings FX 951 FH 200 Chapter 3 Exploded Drawings and Parts List 3 1 Exploded Drawings A B C D E F G H I J K L M 1 2 3 N O P Q R S T U...

Страница 16: ...B2852 H Sales Fuse B2403 250V 2A B2987 250V 1A I Sales Power cord Rubber 2 pole grounding B2387 Vinyl 2 pole grounding B2419 Vinyl 3 conductor CH plug B2436 Without vinyl 3 conductor plug B2421 Molded...

Страница 17: ...ch voltage 100V 110V 120V 220V 230V 240V 1 Repair Holder B3073 2 Repair Only receptacle Please let us know the following part number when ordering 699 031236 3 Repair Jack PJ 35N With nut B3329 Repair...

Страница 18: ...and secure them with 5 screws P tight round head screw M3 16 Figs 4 1 3 4 1 5 and 4 1 6 NOTE Check that the cushion rubber B is installed in the case R and the cushion rubber A is installed in the cas...

Страница 19: ...First Edition March 31 2007 4 1 Opening the Cover FX 951 FH 200 Fig 4 1 7 Rubber feet Two rubber feet are installed for each case Cushion rubber B Fig 4 1 6 Cushion rubber A Fig 4 1 5 Case L Case R...

Страница 20: ...re for jack 5 Remove 4 screws and then disconnect the P W B for control from the front panel Fig 4 2 2 6 Remove 4 screws and then disconnect the P W B for connector and holder from the front panel Fig...

Страница 21: ...sections of the front panel 4 Run the lead wire of the connector section under the P W B to insert and pull the card smoothly Fig 4 2 6 5 Mount the grounding wire of the P W B onto the grounding plate...

Страница 22: ...e and transformer Grounding wires for P W B and jack Assembly procedures Power receptacle power switch and transformer 1 Mount the transformer and grounding plate onto case L with 4 screws TP Bind B1...

Страница 23: ...ig 4 3 3 Assembly procedure 5 Solder the grounding wire Assembly procedure 5 Solder the white lead wire of the transformer Assembly procedure 4 Solder the black lead wire of the transformer Assembly p...

Страница 24: ...plate and chassis 4 4 1 NOTE The external tooth lock washer is installed in only one place Be careful not to lose it 5 Remove the nut outside the case to remove the jack from the case 4 4 2 4 4 7 4 4...

Страница 25: ...position of the transformer NOTE Make sure that the lead wires for jack does not get caught 5 Attach the grounding wires for jack and P W B to the grounding plate with one screw pan head screw M4 x 6...

Страница 26: ...e 3 The spacer is installed between the screw and iron holder base There is another spacer on the opposite side Screws in disassembly 1 Screw in disassembly 2 4 5 2 Pan head screw with spring washer P...

Страница 27: ...rst Edition March 31 2007 5 Wiring Diagram FX 951 FH 200 White Black Red Red Power receptacle Power switch Power receptacle P W B Jack Grounding plate Control P W B Transformer Chapter 5 Wiring Diagra...

Отзывы: