First Edition: March 31, 2007
2-5 Iron holder check (FX-951/FH-200)
4. Insert the connection cable into the iron holder and check the following points:
•
Does the stay operate smoothly?
If the stay does not smoothly operate:
The iron holder base may be deformed, the spacer may be lost or the spring in the
switch case may be damaged.
Check each point and correct or replenish and replace it.
•
Measure the resistance of the connection cable to check that the switch operates
normally.
NOTE
If the resistance value is “1
Ω
or less” when the tip is placed on the soldering holder
base and the resistance value is “4.7k
Ω
±10%” when the tip is released from the
iron holder, the unit conditions are normal.
If the resistance value is abnormal:
Replace the switch case assembly with a new one.
5. Connect the connecting cable to the iron holder and FX-951 and then check the
power save function.
NOTE
If the connecting cable is not inserted fully into the jack, the power-save function
will not activate.
If the power-save function does not operate normally:
Replace the P.W.B. with a new one.
Apply tester here to measure.
If the resistance value is “4.7k
Ω
±10%”
in this condition, the unit conditions
are normal.
If the resistance value is “1
Ω
or less”
in this condition, the unit conditions
are normal.
Power save setting
0
OFF
1 to 29
Indicates “SLP” after the set time has elapsed.
30
Indicates “---” after 30 minutes.