background image

10/24 

drainage pipe of the pressure release device. This pipe must be left open towards the air space. The 
drainage  pipe  must  be  directed  downwards  (from  the  appliance)  into  a  frost  free  room,  and  free 
drainage  must  be  ensured  towards  the  air  space.  It  is  forbidden  to  divert  water  leakage  in  non  - 
visible manner. 
• The  pressure  reduction valve and  the  safety  valve  must  be  installed and  operated in a  frost free 
environment. • It is forbidden to operate the hot water container without any protective earthing. 
•  The  connection  of  the  container  to  the  electrical  system  must  be  of  a  permanent  design.  It  is 
forbidden to use of a mains socket!  
• Mains supply must be ensured for the tank via a two-pole switch of overvoltage category III (with 
3mm gap between open contacts). 
SERVICE  For  regular  servicing  of  appliances  or  in  the  event  of  a  fault,  please  contact  one  of  our 
contracted service agents listed in the service notes. If you are not satisfi ed with the repair carried 
out  by  the  service

 

agent,  please  contact  the  HAJDU  Hajdúsági  Ipari  Zrt.  customer  service  desk. 

Customer service contact details. Tel.: +36 52 582-787 E-mail: [email protected] 
ENVIRONMENTAL PROTECTION PRECAUTIONS Please note that at the end of the lifecycle of 
the  product  you  have  purchased,  its  characteristics  have  the  potential  to  harm  the  environment, 
primarily the soil and groundwater, since it contains components (for example, cables) that mean at 
the end of its life it is classifi ed as hazardous waste. At the end of its lifecycle, please do not place 
the  appliance  in  general  household  waste.  It  should  be  deposited  with  a  company  engaged  in 
collecting  waste  electrical  appliances  or  returned  to  the  manufacturer  so  that  through  the 
professional  management  and  recycling  of  the  waste  product,  together  we  can  help  protect  the 
environment. 
• If the mains cable is damaged, it must be replaced in order to avoid any danger. Such replacement 
must be performed by the manufacturer, its service support or a similarly qualifi ed professional.  
• The fi rst heating cycle must be supervised by a professional.  
• The electrical safety cover may not be removed, but by a professional; failure to observe this may 
lead to electrical shock or other dangers.  
• To ensure safe operation it is recommended to regularly (every year) have the appliance and the 
combined safety valve checked by a qualifi ed professional for proper operation. Additionally, it is 
also  recommended  to  blow  off  the  valve  every  two  months  by  turning  the  blow  off    button  of  the 
safety valve in the direction indicated by the arrow. This way, the valve seat will be cleaned of any 
possible deposit (scale, sand grains etc.). 
 

 

ATTENTION! 

The packaging contains the following accessories: 

1 pc Instructions for Installation and Use 
1 pc Warranty Card 
Please, make sure to check these when receiving the product.  

 

DEAR CUSTOMER, 

Water  heaters  with  indirect  heating  are  suited  to  produce  domestic  hot  water  using  the  heat 
transferred from the heating medium of any boiler. 
Have all connections to the heating and water supply network, as well as the first start-up performed 
by a qualified technician, taking into account these instructions. 
Please,  carefully  read  and  observe  these  installation  and  operating  instructions.  This  way,  you  can 
ensure the reliable operation of your appliance for a long time. 

 

 
 

Содержание HR-N 30

Страница 1: ...INSTALLATION AND USE MANUAL DEINSTALARE ȘI UTILIZARE HR N 30 HR N 40 ÁLLÓ ELHELYEZÉSŰ ZÁRTRENDSZERŰ INDIREKT FŰTÉSŰ TERMÉK ÎNCĂLZITOARE DE APĂ VERTICALE CU CIRCUIT ÎNCHIS ȘI ÎNCĂLZIRE INDIRECTĂ UPRIGHT CLOSED SYSTEM WATER HEATERS WITH INDIRECT HEATING ...

Страница 2: ...helyezést befejezte köteles a vevő számára egy megfelelőségi nyilatkozatot kibocsátani amely tanúsítja a hatályos törvények és specifikációk betartását Az üzembe helyezést végző cégnek mindkét esetben az egész rendszeren el kell végeznie a biztonsági és üzemeltetési ellenőrzéseket A készüléket ajánlatos leüríteni amennyiben az egy fagyveszélynek kitett helyiségben használaton kívül kerül Ezt a műve...

Страница 3: ...elhasználódott terméket ne a kommunális hulladék közé tegye hanem elektromos berendezések hulladékai begyűjtésével foglalkozó céghez vagy a gyártóhoz jutassa el hogy az elhasználódott termék szakszerű kezelésével újrahasznosításával közösen segítsük elő a környezet megóvását FIGYELEM A csomagolódobozon belül az alábbi tartozékok találhatók 1 db szerelési és használati útmutató 1 db jótállási jegy ...

Страница 4: ...be kell behelyezni a vezérlő egység érzékelőjét és ebbe a zárófedélbe van beszerelve a tartály másodlagos korrózió védelmet biztosító aktív anód is 1 ábra TELEPÍTÉS A termék telepítéséhez a következő feltételeket kell biztosítani Fagyveszély mentes helyiség vízszintes sima padozat hogy a készülék feltétlenül függőlegesen álljon A függőleges állást szükség esetén a lábak állításával ill megfelelően...

Страница 5: ...int az e miatt keletkező károkra A hőcserélő belső felületének korrózió védelme érdekében hő átadó közegként csak a csőhálózatokra megengedett korróziót nem okozó anyagok alkalmazhatók A TÁROLÓT ÉS A HŐCSERÉLŐT A MEGENGEDETT ÜZEMI NYOMÁSNÁL 0 6 MPa NAGYOBB NYOMÁS ALÁ HELYEZNI ÉLETVESZÉLYES ÉS TILOS A kombinált biztonsági szelepet a hidegvízvezetékbe kell bekötni és nyíllal jelölt áramlási irány be...

Страница 6: ...en is azonnal melegvíz folyjon Távoli vízvételi helyek esetén a hőveszteség csökkenése céljából célszerű a melegvízvezetéket hőszigetelő burkolattal ellátni Az ilyen rendszer kiépítéséhez különösen fontos szakember igénybevétele Amennyiben a cirkulációs csonkot nem használják azt le kell zárni egy es zárókupakkal ÜZEMBE HELYEZÉS A vezérlő egység érzékelőjének elhelyezése HR N típusoknál A vezérlő ...

Страница 7: ...ag fedőlapjába épített anódteszterrel ellenőrizheti Az ellenőrzéshez az anódteszter nyomógombját nyomja be Ha a mutató a zöld mezőbe lendül ki az anód állapota megfelelő ha a mutató a piros mezőbe marad az anódot ki kell cserélni Az anód állapotát célszerű legalább havonta kéthavonta ellenőrizni de kétévenként szakszervizzel felül kell vizsgáltatni A vizsgálatot a jótállási jegyen igazoltatni kell...

Страница 8: ...odása esetén forduljon bizalommal a gyárunkkal szerződésben levő szervizekhez melyeknek névsorát a SZERVÍZJEGYZÉK tartalmazza Ha a szerviz által végzett javítással nincs megelégedve forduljon a HAJDU Hajdúsági Ipari Zrt vevőszolgálatához 4243 Téglás Tel 52 582 700 Fax 52 384 12 Megnevezés Zártrendszerű indirekt termék Termékszáma 43 84 3 Típusa HR N 30 HR N 40 Névleges űrtartalom l 120 160 Nettó ű...

Страница 9: ...ing of the entire system When put out of use in a room exposed to freezing you are recommended to drain the appliance This operation must be performed by a qualifi ed professional Running hot water with temperature above 50 C may cause serious burn marks Improper installation may cause injuries to people or animals or cause damages in objects The manufacturer assumes no liability for these Before a...

Страница 10: ...usehold waste It should be deposited with a company engaged in collecting waste electrical appliances or returned to the manufacturer so that through the professional management and recycling of the waste product together we can help protect the environment If the mains cable is damaged it must be replaced in order to avoid any danger Such replacement must be performed by the manufacturer its serv...

Страница 11: ...mometer sensor is placed in the pocket tube located on the closing cover of the upper service opening of the appliance This pocket tube hosts sensor of the control unit and the said cover hosts the active anode providing the secondary corrosion protection of the tank The inner surface of the water heater tank is protected against corrosion by a special enamel coating which is also added the active...

Страница 12: ...m the wall The connection of the inlet and outlet should use as few elbows as possible Proper water supply and sewage network connections must be provided at the site of installation water dripping out of the safety valve must be discharged To decrease heat loss attributable to the hot water pipe the appliance should be installed the closest possible to the hot water withdrawal locations In case o...

Страница 13: ...he combined safety valve must be connected to the cold water pipeline observing the flow direction indicated by the arrow The maximum distance between the appliance and the valve is 2 m and two bends arcs knees are permitted Safety valve max opening pressure 0 7 MPa The safety valve is not included in the delivery IT IS FORBIDDEN TO INSERT WATER PIPELINE FITTINGS BETWEEN THE VALVE AND THE APPLIANC...

Страница 14: ...pocket tube length 460 mm at a height determined based on the output of the boiler used and the frequency and quantity of water withdrawal in such way that the water temperature set on the thermostat should be preferably achieved by the time the boiler first stops If the heating capacity of the boiler exceeds 30 kW the heating capacity must be reduced in order to lower the frequency at which the b...

Страница 15: ...bject to this see the Warranty Card It is very important that the activator must be firmly connected to the tank Therefore when installing a new anode or performing other repairs make sure to connect the active anode the earthing screw and anode tester in such way that proper electrically conductive contacts are achieved If you discover leakage from the interior of the water heater or any other si...

Страница 16: ...ági Ipari Zrt 4243 Téglás Phone 52 582 700 Fax 52 384 126 Description Closed System Indirect Product Part number 43 84 3 Type HR N 30 HR N 40 Rated volume l 120 160 Net volume l 110 140 Max water temperature o C 65 65 Weight kg 64 70 Rated operating pressure bar 6 Heat exchanger rated operating pressure bar 6 Safety valve max opening pressure MPa 0 7 Heat exchanger heating surface m2 1 4 Standby e...

Страница 17: ...Conectarea la rețeaua de încălzire și de apă precum și punerea în funcțiune trebuie efectuate de către un tehnician calificat luând în considerare prevederile acestui manual Studiați cu atenție aceste instrucțiuni privind instalarea și utilizarea aparatului și respectați le cu exactitate Prin urmare aparatul Dvs va funcționa în mod fiabil pe termen lung COMPOZIȚIE STRUCTURALĂ ȘI FUNCȚIONARE Încălz...

Страница 18: ...jul picioarelor sau respectiv prin rezemarea sigură a acestora Aparatul trebuie instalat astfel încât distanța față de perete să fie de min 50 mm Conductele de admisie și evacuare trebuie conectate cu cât mai puține coturi posibile La locul de instalare trebuie asigurată rețeaua de apă și de drenaj adecvată apa care picură prin supapa de siguranță trebuie drenată În scopul scăderii pierderii de că...

Страница 19: ... de apă din cupru la rețea este obligatorie utilizarea pieselor intermediare de etanșare pentru a evita coroziunea electrochimică Piesa intermediară trebuie montată între încălzitorul de apă și rețeaua de apă din cupru În cazul conectării fără piese intermediare nu oferim garanție pentru coroziunea capetelor de conductă filetate ale rezervorului sau pentru daunele cauzate de aceasta Pentru a prote...

Страница 20: ...e apă rece prin robinet O supapă de închidere trebuie montată în conducta de apă rece care duce spre rezervoare înaintea ansamblurilor supapa de siguranță combinată supapa de presiune etc Acest lucru permite deconectarea rezervorului de apă caldă și a ansamblurilor de montaj de instalație de apă de la rețeaua de apă în caz de avarie sau alte lucrări de întreținere Aparatul este prevăzut de asemene...

Страница 21: ...de siguranță este de dorit ca anual un tehnician calificat să verifice funcționarea aparatului și a supapei combinate de siguranță În plus recomandăm ca prin întoarcerea în direcția indicată cu săgeată a butonului de purjare a supapei de siguranță să purjați supapa o dată pe lună sau la două luni Astfel scaunul de supapă este curățat de eventualele depuneri calcar granule de nisip etc Anod activ R...

Страница 22: ... apei de rețea și supapa bateriilor de apă rece apoi deschideți supapa de apă fierbinte a unei baterii și mențineți o deschisă până la finalizarea golirii Reumplerea se face conform celor descrise mai sus CERTIFICAT DE CALITATE DATE TEHNICE Denumire Încălzitor de apă cu circuit închis și încălzire indirectă Nr produs 43 84 3 Tipul HR N 30 HR N 40 Capacitatea nominală l 120 160 Capacitate netă l 11...

Страница 23: ...ICIU DE REPARAȚII Pentru verificări regulate sau în cazul unei defecțiuni a aparatului vă rugăm să contactați service urile aflate în relații contractuală cu fabrica noastră conform listei din CERTIFICATUL DE GARANȚIE Dacă nu sunteți mulțumit de reparația efectuată de către service contactați Serviciul Clienți al HAJDU Hajdúsági Ipari Zrt 4243 Téglás Tel 52 582 700 Fax 52 384 126 ...

Страница 24: ...24 24 1221114364 01 ...

Отзывы: