CLI Command Reference
metadata
Makito X User’s Guide, v2.0, Issue 01
290
metadata
IMPORTANT
Metadata capture is an optional feature and must be installed at the
factory.
S
YNOPSIS
metadata ID start
metadata ID stop
metadata create port=udpport [addr=ipaddr] [name=text]
metadata ID delete
metadata ID set parameter=value [parameter=value ...]
metadata ID get
metadata ID clear
enable_metadata_on_serial_port
enable_console_on_serial_port
D
ESCRIPTION
The
metadata
command is used to manage metadata sources. This command configures
the Makito X to capture either KLV (Key Length Value) or CoT (Cursor on Target)
metadata and then incorporate data information within the metadata elementary stream of
the standard MPEG Transport Stream.
The Makito X supports three metadata input types: either from the COM1 serial port, the
HD-SDI interface, or a user definable UDP network port. The first two apply on the Makito
X-SDI only. UDP is always available.
Multiple metadata sources can be multiplexed into the same Transport Stream. To do so,
you must specify the metadata source ES IDs in the
command (
multiple comma-separated metadata source id/names.
CoT/UDP and CoT/Serial metadata sources can also be retransmitted to other IP destina-
tions for follow-up analysis by third party systems. For more information, see
You can define a small set of static KLV objects for KLV and CoT metadata sources. This
can be used to modify erroneous or insert missing mission IDs and security classification
within outbound TS steams. For more information, see
A
CTIONS
start
Starts the metadata source.
stop