MANOK plus
Faults
102
Order h49 7144.907-333
Fault
Possible cause
Remedial action
Remedied by
Dirty coupling area
in the clamping el-
ement
Remove the clamping element,
clean the coupling area and the
clamping element
Dirty clamping ta-
per
Remove the clamping element
and clean the clamping taper
Geometry error on
the workpiece due
to incorrect type of
clamping element
Use a suitable clamping element
Elastic distortion
Reduce the clamping force to the
level applicable for the clamping
device and the workpiece
Check the workpiece material
Indentations on
the clamping
surface
Clamping force is
too high
Reduce the clamping force to the
level applicable for the clamping
device and the workpiece
Skilled special-
ist
Incorrect type of
clamping element
Use a suitable clamping element
Dirty clamping ele-
ment
Clean the clamping element
Damaged clamp-
ing element
Replace the clamping element
Dimensional differ-
ence between
workpiece diame-
ter and clamping
elements is too
great
Use clamping element with a suit-
able clamping diameter
Table 20: Fault table
13.3 Commissioning after a fault has been remedied
After the fault has been remedied, perform the following
steps to recommission it:
1. Reset the emergency stop equipment.
2. Acknowledge the fault on the control unit of the machine
tool.
3. Ensure that no-one is in the danger area.
4. Start the machine tool.