![Hainbuch HYDROK 100 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/hainbuch/hydrok-100/hydrok-100_operating-instructions-manual_579645025.webp)
HYDROK
Technical data
Order h49 7144.907-333
25
DANGER
Serious injuries caused by projectile parts ejected
when the product is used improperly!
Always pay attention to media feed lines when ro-
tating the product.
When using the side ports, the product must not
ever rotate.
DANGER
Serious injuries caused by parts being ejected
centrifugally due to a non-compliant combination
of several products!
From all of the maximum speeds indicated for the
combined products, always remain at the lowest
of those maximum speeds.
DANGER
Serious injuries caused by workpieces being
ejected centrifugally after a loss of clamping
power!
Never rotate the product without a workpiece in-
stalled.
When several clamping points are involved,
clamp a suitable workpiece to each one.
If necessary, adjust the machining forces.
3.5 Clamping force diagram
The clamping force diagram indicates the permitted range in
which the radial clamping force is permitted to move in re-
sponse to axial actuating force.
The clamping force diagram indicates the influences of fric-
tion and of the clamping diameter.
WARNING
Serious injuries caused by insufficient clamping
force!
The values measured for radial clamping force
F
rad
must be within the permitted range.
If the values recorded are outside the permitted
range, the product must be cleaned [see »Clean-
ing« chapter] and another clamping force test
must be conducted.
If the values recorded after cleaning is completed
are outside the permitted range, you should con-
tact the manufacturer.