23
3.4 Speed
The product is authorized for rotational operation.
DANGER
Serious injuries caused by parts being ejected
centrifugally due to a non-compliant combination
of several products!
From all of the maximum speeds indicated for the
combined products, always remain at the lowest
of those maximum speeds.
3.5 Operating conditions
Indication
Value
Unit
Ambient temperature range
15 - 65
°C
Humidity
≤ 80
%
Table 2:
Operating conditions
3.6 Type designation
The type designation is on the product and it includes the
following indications:
Manufacturer
Product designation
ID number [marked with a # symbol]
Build year
Maximum actuating force
𝐹
𝑎𝑥 𝑚𝑎𝑥
[𝑘𝑁]
Maximum transmissible torque
𝑀
𝑚𝑎𝑥
[𝑁𝑚]