Operation
Operating instructions • Betriebsanleitung • TOPlift L+ edition
81
Shutter door:
The shutter door lights up green when it is closed.
The lock lights up green when the shutter door is locked.
Ladder door:
Lights up red when the ladder door is open.
Railing door / Interlocking:
Lights up red when a railing door or interlocking is open.
End of downwards travel:
Lights up red when the limit switch at the bottom (switch-off rod) has been actuated.
End of upwards travel:
Lights up red when the limit switch at the top has been actuated.
Top safety switch-off:
Lights up red when the top safety switch-off is actuated or the switch-off damper is open.
Ready for upwards operation:
Lights up green when ascent is possible.
Ready for downwards operation:
Lights up green when descent is possible.
Emergency stop:
Lights up red when an emergency stop button has been pressed.
Bottom safety switch-off:
Lights up red when the safety switch-off at the bottom (switch-off plate) has been actuated.
Service:
Lights up yellow when service lift maintenance is overdue (measured by operating hours).
16.2.6
Call function (optional)
Fig. 89: Control element for call
function (optional)
1
Control panel for start platform
2
Control panel for end platform
The tower can be optionally equipped with a “call function” control panel at the
start platform and end platform. This allows the operator to request the service
lift from the start and end platform if it is in a different position. The service lift
must be in an operational condition for this purpose.
The “call function” device is used exclusively for transporting materials or for
carrying out an empty run!