background image

Safety Precautions

Á ¢¼

´Ó ÃÓ

ÚÏ ´Ô

¡

²

»

¿

É

Ò

Ô

Á

¢¼

´Ó

ÃÓ

ÚÏ

´Ô

¡

²

»¿

ÉÒ

Ô

For first use after installation, the tank must be 
full of water before connecting the power. 
Otherwise, heating element overheat may 
cause troubles.Children taking shower must be 
attended by adults.

Please do not point the showerhead towards 
human body when turning on or off the faucet, 
avoiding to be scalded by a small stream of 
hot water. 

Haier

C

In winter in cold regions, for long-term out-of-
use, please lift the safety valve handle to empty 
the water, avoiding ice formation damaging the 
water heater. 

Damaged power cord must be replaced by 
after-service technicians with special cable 
(factory provided). Other persons shall not 
dismantle or repair. In addition, do not place 
flammable matters nearby the water heater.

Do not use damaged wire, socket or appliances 
with loose plug, otherwise accidents like 
electric shock, short circuit and fire may occur. 
Make sure power plug closely fits with power 
socket.

²

»Ð

У

¡

²

»Ð

Ð

Power socket for water heater shall be 
located in a dry place free of water spray. Do 
not insert or pull the power plug with wet 
hands, for accidents like electric shock or 
injury may happen.

  Temperature value indicated on the display is for water around the detection point. Outlet water 
temperature is generally higher. Before use, please first turn on cold water and then adjust water 
temperature as you need. During use, the displayed value is still water temperature at detection point 
instead of outlet temperature. Please do not directly turn on hot water.
   The product adopts Haier

Safe Care

patented technology. In normal installation, even in severe 

case that ground wire is live due to wrong connection, the product 

Safe Care

 technology can filter 

and efficiently ensure your safety. However, whenever your feel a sensory current, please pull out the 
power plug and notify local after-service men in time. Do not dismantle by yourself. 

Check if power meter and wire size are consistent 
with water heater rated current. If necessary, ask 
experienced qualified electricians to check.

The water heater shall use 230 V~ / 50 Hz 
power supply from a separate socket (no 
m u l t i - p u r p o s e   s o c k e t )   a n d  b e   r e l i a b l y  
grounded. Power plug pins shall be cleaned 
in time to avoid any contamination causing 
accidents like fire.

Operation Instructions

9. Delay Time Setting
   Delay function means that, system automatically calculates the time needed to reach 
temperature setting value with a defaulted 2150 W power, then determines the time to 
start heating, and automatically heats to the set temperature before the preset delayed 
time to use hot water. Two Delay Times (Time 1 + Time 2) means machine as needed can 
heat water in two delayed use times. This machine can be manually set two delayed water 
use times. Setting will take PC clock time as reference. Defaulted Time 1 use time is 17:00 
and Time 2 use time is 06:00. In Delay mode, system default heating power 2150 W can't 
be adjusted. 
    Example: as shown in Fig. 12, set delayed use Time 1 at 10:30.

   With machine powered on, consecutively press Mode button until it enters Time 1 
operation status with delay indication and symbol 

 lighted. Press Set button to enter 

Time 1 hour setting status with Time 1 hour digits flashing. Press 

 or 

 button to get 

10:00. While hour digits are flashing, you can press Set button to confirm and enter Time 1 
minute setting. Adjust the value to 10:30 with 

 or 

 button. 

   Then you may press Set button to confirm current settings or wait 6 s after which 
machine automatically confirms and quits. Time 2 time setting is similar to Time 1, i.e. 
press Mode button to enter Time 2 operation mode and set Time 2 time with Set button.
Note: If large quantity hot water is used after delay mode is started and water heaters 
starts heating, resulting in water heater still hasn't reached temperature setting at delayed 
use time, machine will automatically extend heating for half an hour and stops. If actual 
temperature has reached setting value before delayed use time, and it decreases before 
reaching delayed use time, machine will calculate heating time again and determines if re-
heating is needed or not. Likewise, if water heater hasn't reached set temperature at 
delayed use time due to too low supply voltage, machine also automatically extends for 
half an hour and stops.
10. Operation Mode Selection
    After powering on, by consecutively pressing Mode button, system will shift between 
Real-time Heat / Warm (with Real-time indication), Medium Warm (with Medium Warm 
indication), Night Power (with Night Power indication), Time 1 (with Delay and 

 

indication), Time 2 (with Delay and 

 indication) ,Time 1 + Time 2 (with Delay and 

 

indication) and Intelligent (with Intelligent indication) modes. User can select any mode as 
current operation mode. Only after being selected as current operation mode, 
corresponding settings can be executed. 
Example: clock at 7:00, heating power of 2150 W, temperature setting of 75

(temperature 

setting and actual temperature flash alternatively), delayed useTime 1 being set at 10:00. 
If you want to use water at 10:00, machine will automatically heats water to set 
temperature at 10:00. Otherwise (e.g. in Night Power mode as shown in Fig. 13), it doesn't 
execute Time 1 function. You need to select Delay and symbol 

 with Mode button, and 

then Time 1 function can be executed.

11. Powering Off
    After taking shower, you can lightly press On/Off button to power off the machine.

Hints:

With machine powered on, you can press Set button to set On/Off time for various 
modes, and adjust time with 

 or 

 button. In Real-time Heat mode, you can press Set 

button to adjust clock hour and minute values. In Delay mode, you can press Set button 
to set delayed use time. In Medium Warm and Intelligent mode, Set button is inactive.
The machine has multiple safety means like current leakage protection, over-
temperature protection, sensor short-circuit and open-circuit protection, which can 
realize full disconnection and display fault code. All fault protections are unrecoverable 
protection which needs local after-sales service.
This water heater has power failure memory function. You needn't re-set heating power 
level, heating temperature ,clock and operation mode. Machine will directly go to 
previous working status after powering on again.

A.

B.

C.

Never do that

Be sure to act as per instructions

Description of the Symbols

Содержание SILVER SEA-OX FCD-JTHMG100- E

Страница 1: ...future regerence Silver Sea ox Haier Household Electric Water Heater Rev 01 Specific Number 0040501638 Add Haier Garden Qianwangang Road Economic Development Zone Qingdao P R China Group Qingdao Economic and TechnologicalDevelopment District Haier Water Heater Co Ltd ...

Страница 2: ...Continue heating Check Contact service station Contact service station Contact service station Fill water full or contact service station External Cleaning Disconnect power supply before cleaning Gently wipe with wet cloth dipped with a little of mild detergent Do not use gasoline or other solvents Finally dry with dry cloth Keep water heater dry Do not use cleansers containing grinding agent e g ...

Страница 3: ...g power is 2150W and can t be adjusted Ppwer button With machine powered on press this button to shift heating power level between 850 W 1300 W and 2150 W or button Same as Adjust button on control panel If not in clock or delay time adjusting status you can use or button to increase or decrease temperature setting value between 35 75 with an increment 1 If in clock or delay time adjusting status ...

Страница 4: ... water heater will shut down automatically to protect when the induced temperature is lower than 20 The screen shows E3 Please pull the power supply When the environment temperature is higher than 19 E3 on the screen will disappear as water heater restart D E F Attentions in Operation To avoid causing machine troubles do not connect power before tank is full of water Adjust a suitable temperature ...

Страница 5: ...l it enters Time 1 operation status with delay indication and symbol lighted Press Set button to enter Time 1 hour setting status with Time 1 hour digits flashing Press or button to get 10 00 While hour digits are flashing you can press Set button to confirm and enter Time 1 minute setting Adjust the value to 10 30 with or button Then you may press Set button to confirm current settings or wait 6 ...

Страница 6: ...would use hot water in early morning you may adjust operation mode to Night Power mode Machine will heat warm in default period 0 00 on and 6 00 off Heating power level and highest temperature can be manually set In this mode you can press Set button to calibrate clock time In addition in regional power consumption regulations night power price rate is lower than in day so Night Power mode will be...

Страница 7: ...tting temperature again It repeats in this way HEATING SET HEATING ACTUAL Fig 8 Fig 9 Example Fig 9 shows real time heat warm status with heating power 1300W and temperature setting 75 6 Medium Warm Setting With machine powered on as described in Item 10 press Mode button until it enters Medium Warm operation mode with Medium Warm indication on the display Fig 1 Remarks the permitted error limit o...

Страница 8: ...r heater Insert wall rack onto the hooks and bolts Fit flat washers rear wires and nuts in turn onto the bolts see Fig 3 Tighten the nuts and check them firm Install accessories such as safety valve drain hose as shown in Fig 4 Use sealing compound to prevent water leakage Fig 2 L1 L2 Fig 3 To facilitate installation and removal it is suggested a G 1 2 movable nut is fitted at appropriate location...

Отзывы: