Haier QBJ1-130A Скачать руководство пользователя страница 1

Instruction for use 

QBJ1-130A
QBJ1-150A
QBJ1-175A
QBJ1-200A

Please read this manual before usage
Retain it for future reference

 Solar Water Heater

Models:

Содержание QBJ1-130A

Страница 1: ...Instruction for use QBJ1 130A QBJ1 150A QBJ1 175A QBJ1 200A Please read this manual before usage Retain it for future reference Solar Water Heater Models ...

Страница 2: ...eference The international star service of Haier Group will always accompany you No matter what kind of problems you meet in usage please contact with the local after sales service agent We are at your service all the time Thanks again for choosing Haier Product The water heater you purchased may not full comply with the figure in the manual due to the improvement of product We apologize for the i...

Страница 3: ...10 10 9 Precautions Notice Technical data 4 Packing list The location Exterior and installation dimension Tank assembly Frame assembly Frame fastness Glass tube assembly Extraventricular plumbing instructions Indoor plumbing instructions Installation notice Using Instruction The operation method Troubles treatment 3 ...

Страница 4: ...ts Outer shell Evacuated tubes Base support Cover Silicon seal ring Frame Foot cushion Models Specification of tubes Collector frame angle standard fixed Number of tubes Aperture area Volume of one tube Usable water Gross weight 58mm 1800mm all glass evacuated tubular collector 45 Remarks 1 The warp of a parameters is 3 the warp of usable water parameters is 5 The permitted error limit of other pa...

Страница 5: ...e water depend on the fall of the tank and the water exit an pressurize equipment is recommended while the water couldn t be supplied normally due to the low fall 6 Do not supply cold water more than once in a low solar irradiance day 7 The energy is from solar in the days that lack of solar such as rainy or snowy day the temperature of the water may can t reach your demand 8 Make sure the evacuat...

Страница 6: ...iliarize yourself with the function of this production 1 Please check out the packing list 2 To avoid the scald please mix the hot and the cold water before use it 3 In order to protect the tank please don t refit or wall up the air supply pipe and the overflow pipe ...

Страница 7: ...1 Please install the solar water heater in the area that avoid the thunder 2 Solar water heater angle range east to south for 10 west to south for 15 3 There shouldn t be any hindrance in front of the heater or the distance should over L L H tg 66 5 a H height of the hindrance a latitude of the area Remarks The permitted error limit of above parameters is 10 The location B A D H ...

Страница 8: ...gure of the frame and packing list in the packing of frame Frame fastness 1 Peg the feet of the heater into the earth with prepared iron or into the concrete brick with intumescent bolt 2 Adjust the height of the frame with the water proof cushion to keep the tank aclinic and each foot balanceable Notice 1 Make sure that the feet are all attach the floor closely or it will cause the distortion of ...

Страница 9: ...nsert tube into base support C 5 Slide the tube down 1 cm Slide black rubber seal up the tubes until it sits flush with tank 6 Insert one tube on either end of the tank to achieve alignment of unit Notice 1 Make sure the silicon seal ring are clean and well positioned 2 Place the rounded side of rubber seal downwards on open end of tube Slide it down 10 cm Wet open end of tube to make it easier to...

Страница 10: ...er flow pipe Over flow hole conect to the room n A a b Indoor plumbing instructions Solar water heater Tap water Hot water Over flow pipe Inlet outlet hole 1 2 conect to the room Air supply hole 1 2 forbidden to stem A b a Remarks The permitted error limit of above parameters is 10 ...

Страница 11: ...e and the cloaca should less than 15cm Don t placed the pipe optionally so can avoid the water spatter 4 Don t install the valve in the pipeline to insure that the signal which shows the water is overflow will be worked normally 5 To avoid the water in the tank flow inverted an unilateralism valve should be installed at the joint of the water pipe and the tap water 6 The installation project shoul...

Страница 12: ... flowing out of the overflow pipe indicate that the tank is full of water close K1 at this time 3 Open K2 when you want to use the water open K3 to adjust the temperature if it is too high 4 Close K2 and K3 when finish using the water Using Instruction 9 Air supply pipe Tap water Over flow pipe Water supply valve ...

Страница 13: ... are hindrance in front of it Treatment Supply water according to the manual Maintain the pipeline or clean the connection Replacing the tubes Waiting for the supplying again Maintain the pipeline and the connection Screw down the valve or replacing it Change the location or move the hindranc Using Instruction 10 The controller can t reach the programmed level or there is no water Too much ash on ...

Страница 14: ......

Страница 15: ......

Страница 16: ...Rev 01 Specific Number 0040500680A ...

Отзывы: