– 69 –
Service Mode Tests
Test
No.
Test Name
Description
0
All LED’s on
All LED's on the display will blink including "88" on the SSD at a rate of
1Hz
1
Fault Codes
•
Pressing Start pad will blink the first fault code.
• Display fault code in SSD.
•
At end of list, OR if no fault codes are present, unit will flash "- -".
• Use the fault table.
• Faults with an ID greater than 100 will not be displayed. These are
"engineering faults".
2
Personality ID
• Pressing Start/Pause will start the test.
• Flash the set personality after pressing Start.
• Use SSD to show personality.
3
MC Application
Version (Critical)
After selecting this test, press the Start pad to toggle through the software
version number as follows:
Example: v01.23
• First Press: "01" on SSD
• Second Press: "23" on SSD
4
MC Application
Version (Non
Critical)
After selecting this test, press the Start pad to toggle through the software
version number as follows:
Example: v01.23
• First Press: "01" on SSD
• Second Press: "23" on SSD
5
MC Parametric
Version (Non
Critical)
After selecting this test, press the Start pad to toggle through the software
version number as follows:
Example: v01.23
• First Press: "01" on SSD
• Second Press: "23" on SSD
NOTE
: We only show the Non-Critical version number because the
Critical parametric version number must match the application Non-Critical
version number for the control to boot. If you get to service mode, then the
parametric Critical version is correct.
6
Hot Water Valve •
Pressing Start/Pause will toggle the hot water valve on and off.
• Door will lock while test is active.
• Test will have a timeout for how long valve will be on (1 minute).
•
The valve will turn off when the test is exited.
7
Cold Water
Valve
•
Pressing Start/Pause will toggle the cold water valve on and off.
• Door will lock while test is active.
• Test will have a timeout for how long valve will be on (1 minute).
•
The valve will turn off when the test is exited.
8
Fabric Softener
Dispenser
•
Pressing Start/Pause will toggle the fabric softener valve on and off.
• Door will lock while test is active.
• Test will have a timeout for how long valve will be on (1 minute).
•
The valve will turn off when the test is exited.
(
Continued next page
)