– 46 –
Fault
Code
Description
Trigger Condition
Action
E00
No Fault
- -
• There are no faults to display.
E01
Inlet Thermistor
Short
When the inlet thermistor
readings exceed the minimum
threshold (0.2V) for 5 minutes,
an inlet thermistor fault is set.
• Check Resistance, connector and
wiring.
• Replace thermistor if necessary.
E02
Outlet
Thermistor Short
When the outlet thermistor
readings exceed the minimum
threshold (0.2V) for 5 minutes,
an outlet thermistor fault is
set.
• Check Resistance, connector and
wiring.
• Replace thermistor if necessary.
E03
Inlet Thermistor
Open
When the inlet thermistor
readings exceed the minimum
threshold (4.8V) for 5 minutes,
an inlet thermistor open fault
is set.
• Check Resistance, connector and
wiring.
• Replace thermistor if necessary.
E04
Outlet
Thermistor
Open
When the inlet thermistor
readings exceed the minimum
threshold (4.8V) for 5 minutes,
an outlet thermistor open fault
is set.
• Check Resistance, connector and
wiring.
• Replace thermistor if necessary.
E05
EEPROM CRC
Fault
Bad CRC (Cyclic Redundancy
Check) detected when reading
a page from EEPROM.
• Check and replace user interface
board if necessary.
E06
Stuck Button
If a button is depressed for 1
minute, it will be logged as a
stuck button.
• Check Start and power buttons.
• Check capacitive touch board.
• Replace user interface board if
necessary.
E07
Mis-wired
L1 and N mis-wired (L1 and N
AC input > 162V).
• Check L1 and Neutral Voltage.
• L1 and Neutral needs to be rewired if
necessary.
E08
Door Latch
Stuck
Five cycles are run and door
signal in the hardware door
switch detection circuit has not
opened.
• If fault is not cleared after the door is
opened, check the door switch, main
board or harness.
• Replace main board if necessary.
E09
Door Signal
Stuck
Five cycles are run and door
signal in the hardware door
switch detection circuit has not
opened.
• If fault is not cleared after the door is
opened, check the door switch, main
board or harness.
• Replace main board if necessary.
Fault Codes
Содержание GE GFD14ESSNWW
Страница 1: ...31 9309 24 Inch Vented Dryer GFD14ESSNWW Technical Service Guide August 2019 Rev 1 6 24 20 ...
Страница 23: ... 23 Top View LED Drum Light Main Board Rear Outlet Fuse Rear Outlet Front RJ45 Connector Terminal Block ...
Страница 24: ... 24 Rear View ...
Страница 27: ... 27 CON1 CON 1 DC Voltage Comm in from User Interface UI Board Capacitive Touch Board Connections ...
Страница 48: ... 48 Wiring Diagram ...