background image

10

• A person shall be specially assigned for daily check and record of the product operating 
conditions, in case the temperature inside the bin is on the high side or on the low side, just 
transfer the articles to the other freezers till the fault is removed and then replace back the 
articles.

• Before putting any article in the freezer, please confi rm that the temperature required for 
the article is consistent with the temperature range of this product in advance, in order not to 
damage the article due to the failure of this product to reach to the temperature required for the 
article.

• The indicated temperature of this product may have a certain difference with the actual 
temperature inside the bins due to refrigeration inertia, this is normal.

• The temperature within the topside drawer of freezer would be relatively higher than that in 
other drawers, so, for any article with strict requirements for temperature should be placed in 
other drawers as possible.

• All the freezers are of storage equipment, and it is strictly forbidden to put excessive articles 
that are relatively too hot in one go, this will cause long time of running of the compressor 
without stop, slow drop of temperature, thus affecting service life of the compressor, the articles 
must be put in batches so that the temperature drops in steps till the required temperature is 
reached.

• Do not use any mechanic tool or other means without permit from manufacturer to accelerate 
the process of defrosting.

• Do not spoil the refrigerating circuit.

• Inside the freezer, do not use the electric appliance without production permission.

The freezers can retain their operation parameters when there is power outage.  When the power 
recovers, they will continue to operate based on the saved parameters.

• Under outage or other fault, the freezer would stop and the inner temperature 
will rise. If the power could not be recovered in a short time, please take out the 
articles and store them by other means, in order to avoid any loss caused by article 
damage.

• Once the power of the freezer is cut off, wait for over 5 minutes before it is 
reconnected so as not to damage the compressor or the system.

• Pull out the power plug when the freezer is not in service for a long time and 
turn off the battery switch if applicable, so as to prevent electric shock, leakage of 
electricity or fi re due to aging of the power cord.

• If the freezer is left unused for a long time in an unattended area, make sure 
that children will not approach the freezer and the freezer door can not be closed 
completely.

Operation after a power failure

15

Alarm

• When the temperature captured by sensor is higher than+5

 (or higher than the setting value of 

high-temperature alarm), "AH" and temperature will be alternately shown; when the temperature 
captured by sensor is lower than -5

 (or lower than the setting value of low-temperature alarm), "AL" 

and temperature will be alternately shown.

• For any short circuit, open circuit, or fault, or incorrect connection happens on the temperature 
sensing probe,  "Err" will be shown, and when the sensor's temperature is higher than 85

, "EHi" 

will be shown, and when lower than -50

, "ELo" will be shown. At the same time, the beeper for 

temperature controller will be initiated, and corresponding alarm parameter (such as Err, Ehi, Elo) will 
be shown on the screen correspondingly, as well as the alarm mark (without display of temperature).

• If the temperature sensing probe is judged for error, power should be cut off, and 
the connection of sensing probe should be checked fi rstly.

• If any internal code is shown when the user is adjusting the temperature 
controller, please wait for 1 minute until the temperature is shown again, in order to 
prevent from any fault due to any change of control parameter.

• Under alarm, the beeper alarm could be ceased by pressing any key, and the fl ashing alarm and 
remote alarm will not be ceased).

• If the alarm condition is still available, the beeper alarm will be recovered automatically 30 minutes 
after ceasing.

Automatic recovery of alarm

Содержание DW-60W138

Страница 1: ...d code 0270501299WD V13026 Certificate of Quality checker Model DW 60W138 DW 60W258 DW 60W388 DW 40W100J DW 40W255J DW 40W380J Deep Freezer Operation Manual Read the Operation Manual carefully before using your appliance Keep the Operation Manual in a safe place Appearance color and layout of the door may vary Translation of the original instruction The product is fit for low temperature storing g...

Страница 2: ...25 ...

Страница 3: ...sehold refrigerator 60 C instantaneous quick freezing firmly lock the original fresh nutrition HC hydrocarbon refrigeration technology saving half the power User friendly design of computer control mode intelligence without anxiety adjustment free High performance insulation layer with better thermal insulation effect People based design such as safety door latch Inner temperature DW 60W138 258 388...

Страница 4: ...asket loading of each 1 max 10kg 2 max 10kg 6 max 10kg Refrigeration Direct cooling Exterior Interior Spraying steel plate Stainless steel Condenser Evaporator Wire and tube type coil tube type Temperature control Microprocessor controlled Refrigerant R290 45g R290 55g R290 65g Weight kg 52 76 90 Temperature range 20 40 Voltage 220 240V 50Hz Rated power current W 260 370 450 Noise Level dB A 42 42...

Страница 5: ...5 Technical information may vary from the appliance that you have just purchased due to technical improvements 3 Dear Customers Thank you for choosing Haier deep freezer Please make sure that you have carefully read the manual and follow the instruction as outlined This is to prevent personal injury and damage to products Ignoring this warning may result in death or serious injury Actions or opera...

Страница 6: ...e any vessel containing water or any heavy object on the freezer If the object drops off it may cause personal injury and the flowing water will degenerate the insulation and further cause leakage of electricity or electric shock Do not make the freezer earthed via a gas pipe power supply conduit telephone line or lightning rod The above earthing will cause an electric shock or other dangers Do not...

Страница 7: ...l the refrigerating circuit Do not use any electric appliance in the store room of the freezer except for the types that the manufacturer recommended for use Disposal of discarded freezer shall be conducted by the relevant personnel Dismantle the door to prevent occurrence of accidents such as suffocation Do not set off hazardous articles that are inflammable explosive or volatilizable in the freez...

Страница 8: ...e freezer in order not to make the refrigerating system overloaded d When putting or taking the articles each time please minimize the time for door closing in order to reduce the energy consumption and keep the temperature within the freezer relatively stable Application guidelines Meaning of crossed out wheeled dustbin Do not dispose of electrical appliances as unsorted municipal waste use separ...

Страница 9: ... normal operation and optimum performance level of the freezer its installation place shall conform to the following conditions It can not be installed in a narrow small and airtight space the door frame of the room for placing it shall not be less than and lower than this product and shall at least guarantee its normal passing in and out so as to avoid any maintenance difficulty and failure of in ...

Страница 10: ...urs before powering up the unit 17 If you have any questions about the operation of the unit please refer to the following first If an issue persists contact your after sales office Do not maintain and dismantle the freezer by yourself Fault Troubleshooting The freezer does not work Whether the power connection is normal or not Whether the supply voltage is too low or not Check whether all the tempe...

Страница 11: ...r to defrost naturally After frost melts well discard the water from the drawers or drain it from the drainage hole Dry the bottom of bin with a dry cloth Restart the equipment after the bin is cleaned well Put all articles back in the bin that has already been cooled down Do not use knife or screwdriver or similar tools with sharp edges to defrost Defrosting should be carried out once per month u...

Страница 12: ... please take out the articles and store them by other means in order to avoid any loss caused by article damage Once the power of the freezer is cut off wait for over 5 minutes before it is reconnected so as not to damage the compressor or the system Pull out the power plug when the freezer is not in service for a long time and turn off the battery switch if applicable so as to prevent electric sh...

Страница 13: ...cult for open that is because the pressure within the bin is too small due to low temperature At that time you could open the end cap at the outer side of test hole in order to reduce the internal pressure so that the door cover could be opened The picture above is only a schematic diagram and the test hole is located at different site due to different model so please carry out relevant operation ...

Страница 14: ... shows the setting temperature 2 Press the key again and the screen will then show the inner temperature Setting temperature The thermostat on the control panel of the low temperature freezer can manually set the control parameters 1 Press the key for more than 1 second the screen shows the setting temperature 2 Set a new temperature the screen shows the setting temperature press the key or key to...

Отзывы: