Commercial Air Conditioner
Model: AU96NATAEA
AD96NAHAEA,
AP96NACAEA
28
According to the piping method, connect the piping on indoor unit with union of connecting pipe.
Arrange the piping as per the wall hole and bind drain hose connecting electric cable and piping
together with polyethylene tape.
Insert the bound piping connecting electric cable and drain hose through wall hole to connect
with outdoor unit.
Arrangement of drain hose
Drain hose shall be placed in under place.
There should be a slope when arrange drain hose. Avoid up and down waves in drain hose.
Indoor unit
Slope
Good
Up
Down
Bad
If humidity is high, drain pipe( especially in room and indoor unit ) must be covered with insulation
material.
Insulation material
Copper tube
Drain hose
Connecting electric cable
for indoor and outdoor unit
Please remove the cover piece on the gas pipe and the screw cap on the liquid pipe.
Main points of installation refrigerant pipe
Please install the gas pipe and liquid pipe according to the following shown method.
Please connect the connecting pipes between indoor and outdoor unit according to the
following method.
a) When introducing the pipe from right side
Use attached accessory <A> to connect the on-the-spot connecting pipe and gas
pipe.
B
A
A
B
2