background image

20

WARNING OPERATION

Heat pump type warming
With the heat pump type warming, the mechanism of heat pump that concentrate heat of
outdoor air with the help of refrigerant to warm the indoor space, is utilized.

Defrosting operation
when a room is warmed with a heat pump type air conditioner, frost accumulates on the
heat exchanger of outdoor unit along with the drop of indoor temperature. Since the accu-
mulated frost reduces the effect of warming, it is necessary to automatically switch the op-
eration to the defrosting mode. During the defrosting operation heating operation is inter-
rupted.

Atmospheric temperature and warming capacity
Warming capacity of heat pump type air conditioner decrease along with the drop of out-
door temperature.
When the warming capacity is not sufficient, it is recommended to use another heating im-
plement.

Period of warm-up
Since the heat pump type air conditioner employs a method to circu-
late warm winds to warm the entire space of a room, it takes time be-
fore the room temperature rises.
It is recommendable to start the operation a little earlier in a very
cold morning.

IS THE UNIT INSTALLED CORRECTLY?

Confirm the following items for safe and comfortable use of air conditioner.

The installation work is to be burden on the sales dealer, and do not conduct it by yourself.

Installation place

Avoid installing the air conditioner
near the place where possibility of in-
flammable gas leakage exists.

Install the unit at well ventilated

place.

Install the air conditioner firmly
on the foundation that can fully
support the weight of the unit.

Explosion (Ignition) may occur.

If some obstacle exist, it may cause
capacity reduction or noise increase.

If not, it may cause vibration or noise.

Select the place  so  as  not  to
annoy neighbor with the hot air
or noise

It is advisable not to install the air conditioner at the following special place.
It may cause malfunction,consult the sales dealer when you have to install the
unit on such a place.

The place where corrosive gas generates (Hot spring area etc.)
The place where salt breeze blows (Seaside etc.)
The place where dense soot smoke exists
The place where humidity is extraordinarily high
The place near the machine which radiates the electromagnetic wave
The place where voltage variation is considerably large

Содержание AB182ACACA

Страница 1: ...F CASSETTE AIR CONDITIONER AB182ACMCA AU182AFMCA HBU 18CC03 AB182ACACA AU182AFACA HBU 18HC03 AB182ACNAA AU182AFNAA HBU 18CA03 R1 AB182ACBBA AU182AFBAA HBU 18HC03 R1 AB184ACMAA AU184AFMCA HBU 18C13 AB182ACNBA AU182AFNBA HBU 18CC03 R1 ...

Страница 2: ...CH PART AND ITS FUNCTION INTRODUCTION TO SPARE PARTS REMOTE CONTROLLER OPERATION GUIDE TO OPERATION AIR FLOW DIRECTION ADJUSTMENT PROCEDURE FOR COMFORTABLE USE CARE AND MAINTENANCE WARNING OPERATION 2 3 4 5 6 7 8 12 13 15 16 17 19 20 24 ...

Страница 3: ...l the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house Safety Instructions and Warnings Before starting the air conditioner read the information given in the User s Guid...

Страница 4: ...ust be properly grounded in accordance with specifications Always remember to unplug the air conditioner before opening inlet grill Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the outlet Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User s Guide Installation ...

Страница 5: ...ed B a c ku ps w i t c h S w i n g l o u v e r Airblowsoutfromhere A i r f l o w d i r e c t i o n i s a d j u s t e d W i r e l e s s R e m o t e c o n t r o l l e r Air inlet grille T a k e s i n t h e i n d o o r a i r Air filter R e m o v e s d u s t o r d i r t o u t o f t h e i n l e t a i r In the Air inlet grille A i r i n l e t Outdoor unit A i r o u t l e t C o m p r e s s o r i n s i d ...

Страница 6: ...ing UsedtoconfirmTimer and Clock settings Used to select sleep mode Usedtoselectfanspeed LO MID HI AUTO Usedtoselectyour desired temp Cautions Oncoolingonlyunit heatingmodeisnotavailable A f t e rr e p l a c i n gb a t t e r i e s p r e s sO N O F F a n dd i s p l a y becomes as follows Operation mode AUTO Temp 24 C Timer mode No Fan speed AUTO Note 1 Theaboveinformationisthe explanationof thedisp...

Страница 7: ...ler clock should be adjusted as follows Press CLOCK button AM or PM flashes Press or tosetcorrecttime Eachpresswillincreaseordecrease1min Ifthe button is kept depressed time will change quickly Aftertimesettingisconfirmed pressSET AM and PM stopflashing whileclock starts working Afterreplacingwithnewbatteries remotecontrollerwillconductself check displaying all information on LCD Then it will beco...

Страница 8: ... should be shorter Loading of the battery Load the batteries as illustrated 2R 03batteries resettingkey cylinder Remove the battery cover Slightlypress andpushdownthecover Load the battery Besurethattheloadingisinlinewiththe polerequest as illustrated Put on the cover again Confirmation indicator Indisorderation reloadthebatteriesorloadthenewbatteries after 5mins Note Use two new same typed batter...

Страница 9: ...iousoperationstatusappearsondisplay Not Timer setting Power indicator on indoor unit lights up Press MODE button For each press operation mode changes as follows Unit will run in selected mode stop display at FAN Press FAN button For each press fan speed changes as follows Unit will run at selected fan speed Adjustairflowdirectionifnecessary refertopage13 Press ON OFF button Only time remains on L...

Страница 10: ...For each press operation mode changes as follows UnitwillruninoperationmodedisplayedonLCD Stop display at your desired mode Hints Unitwillstartrunningtoreachthetemp settingonLCD Remotecontrollercanmemorizeeachoperationstatus Whenstartingitnexttime just press ON OFF button and unit will run in previous status AUTO COOL DRY HEAT FAN Press TEMP button Everytimethebuttonispressed temp settingincreases...

Страница 11: ... in HEAT mode adjusting air flow downward will be much more helpful for a better air circulation Be careful not to catch a cold when cold air blows downward Itisharmfultoyourhealthinsummertogofrequentlyinandoutofplaceswheretemp difference is above 7 C Temp difference of 3 5 C will remove your fatigue More than this unit s load can be reduced and power consumption cut down as well So you d better s...

Страница 12: ...ases10min If button is kept depressed time will change quickly Everytimethebuttonispressed timedecreases10min Ifbuttoniskeptdepressed timewillchangequickly Time willbeshownonLCD Itcanbeadjustedwithin24hours 4 Confirming your setting After setting correct time press SETbutton to confirm ON or OFF stops flashing Time displayed Unit starts or stops at x hour x min TIMER ON or TIMER OFF Timer mode ind...

Страница 13: ...press TIMER button to confirm ON stops blinking While OFF starts blinking Time displayed Unit starts at X hour X min To cancel TIMER mode Just press TIMER button several times until TIMER mode disappears According to the Time setting sequence of TIMER ON or TIMER OFF either Start Stop or Stop Start can be achieved Press HOUR button 1 After unit start select your desired operation mode Every time t...

Страница 14: ...in the following sequence SWING No indication louver stopped Change to the AIRFLOW mode SWING LOUVER STOPPED Louver moves in up ward and downward directions continuous ly When the LOUVER button is pushed during SWING mode it stops swinging at the just angle Avoid direct air flow to the body for many hours Avoid downward blowing operation of cooling mode for many hours Do not touch the swing louver...

Страница 15: ...matically close after 3hrs continuous operation The actral temperature is lower than the setting one which is to prevent from being too hot to your sleep In heating mode Note In AUTO mode unit will run in SLEEP function according to the operation mode After setting SLEEP function it is forbidden to calibrate clock If the set sleep time does not reach 8 hours the unit will stop operation automatica...

Страница 16: ... power after the power failure compensation is set if the air conditioner will not be used for a long time please cut off the power supply to prevent its operation from being resumed after the power is supplied again or press the Switch On Off button after the power comes again After the power failure compensation is set if power failure suddenly occurs while the air conditioner is working it will...

Страница 17: ...w i n d d i r e c t l y t o s m a l l a n i mals or plants I f y o u f e e l c o l d o n t h e f e e t b e c a u s e o f h i g h c e i l i n g i t i s r e c o m m e n d e d t o u s e the circulator Fordetails contactyourdealer 43 15 26 7 8 24 18 C C C C C C C C C C C C C 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person An ex...

Страница 18: ...2 Howtoremovethefilter H o l dt h eh o o kp a r tw i t hf i n g e r sa s i l l u s t r a t e db e l o w t w o p o s i t i o n s a t l e f t a n d r i g h t a t l o w e r p a r t o f f i l t e ra n dp u l lt o w a r dt h i ss i d ew h i l es l i g h t l yp u s h i n g upward 2 Afterdryingtheairfilter setitupontheair conditioner Iftheairfilterisverydirty dissolveneutral detergent in the lukewarm wat...

Страница 19: ...heearthleakage breaker in action I t i s d a n g e r o u s T u r n o f f t h e p o w e r s u p p l y s w i t c h i m m e d i a t e l y a n d c o n t a c t t h e s a l e s dealer Coolingorheatingisnotsufficient I st h et h e m o s t a ta d j u s ta s required I s n t t h e a i r f i l t e r d i r t y I s n ta n yd o o r so rw i n d o w left opened D o e s n ta n yo b s t a c l ee x i s t a tt h ea ...

Страница 20: ...nerates fromtheoutdoorunitduring heating U n i t d o e s n o t s t a r t d e f r o s t i n g o p e r a t i o n W a i t f o r t h r e e m i n u t e s Whentheairconditionerisusedatrestaurantetc wheredenseedible oilfumeisalwaysexists whitefogsometimesblowsoutofairoutlet during operation Inthiscaseconsultsalesdealerforcleaningtheheatexchanger T opreventfrostfrombeingaccumulatedontheindoorunitheatex ch...

Страница 21: ...lowing items for safe and comfortable use of air conditioner Theinstallationworkistobeburdenonthesalesdealer anddonotconductitbyyourself Installationplace Avoidinstallingtheairconditioner neartheplacewherepossibilityofin flammable gas leakage exists Installtheunitatwellventilated place Installtheairconditionerfirmly onthefoundationthatcanfully supporttheweightoftheunit E x p l o s i o n I g n i t ...

Страница 22: ...nual keepitalwaysathandforreadyconsultation Iftheopera tor is replaced make sure to hand over this manual to the new operator S t r i c t l yp r o h i b i t e d Observe instructions faithfully Provide a positive grounding WARNING Thesystemshouldbeappliedto places as office restaurant residence and the like Thesystemshouldbeinstalled byyourdealeroraprofessional installer Whenyouneedsomeoptionaldevi...

Страница 23: ... y c o u l d r e s u l t b y a c a r e l e s s installation G r o u n d i n gc a b l es h o u l dn e v e rb ec o n n e c t e dt oag a sp i p e c i t yw a t e rp i p e l i g h t n i n gc o n d u c t o rr o do rg r o u n d i n g c a b l eo ft e l e p h o n e I ft h eg r o u n d i n g c a b l e i s n o t s e t p r o p e r l y i t c o u l d c a u s e electric shocks Y oushouldrefrainfromexposing yourb...

Страница 24: ... c t r i c s h o c k s Donotinstallthesystemwhere thewindofblowerreachesdi rectly the flora and fauna Makesuretouseafuseofprop er electric rating I t w i l l n o t b e g o o d f o r t h e i r h e a l t h U s eo fs t e e lo rc o p p e rw i r ei np l a c eo f a f u s e i s s t r i c t l y p r o h i b i t e d b e c a u s e i t c o u l dr e s u l ti nat r o u b l eo rf i r ea c c i dent Neitherstandon...

Страница 25: ...a repair consult your dealer Improper practice of repair could cause water leakage electric shock or fire When the air conditioner is relocated contact you dealer or a professional installer Improper practice of installation could cause water leakage electric shock or fire When operating the system simultaneously with a comb ustion apparatus indoor air must be ventilated frequently Check occasiona...

Отзывы: