                   Your air conditioning product is marked with this

                   symbol.This means that electrical and electronic

                   products shall not be mixed with unsorted

                   household waste.Do not try to dismantle the

                   system yourself:the dismantling of the air

conditioning system,treatment of the refrigerant,of oil and of

other part must be done by a qualified installer in accordance

with relevant local and national legislation.Air conditioners

must be treated at a specialized treatment facility for reuse,

recycling and recovery.By ensuring this product is disposed

of correctly,you will help to prevent potential negative cons-

equences for the environment and human health.Please

contact the installer or local authority for more information.

Battery must be removed from the remote controller and dis-

posed of separately in accordance with relevant local and

national legislation.

The products are fulfilled with the requirements in the

directive 2011/65/EU of the European parliament and of

council on the Restriction of the use of Certain Hazardous

Substances in Electrical and Electronic Equipment(EU

RoHS Directive)

WEEE

In accordance with the directive 2012/19/EU of the European

parliament,herewith we inform the consumer about the dis-

posal requirements of the electrical and electronic products.

DISPOSAL REQUIREMENTS:

Contains fluorinated greenhouse gases

 covered by the Kyoto Protocol

This product contains fluorinated greenhouse gases covered

by the Kyoto Protocol.Do not vent into the atmosphere.

Refrigerant type:R32

GWP*value:675

GWP=global warming potential

Please fill in with indelible ink,

 

1      the factory refrigerant charge of the product

 

2      the additional refrigerant amount charged in the field

            and

 

1+2  the total refrigerant charge

 on the refrigerant charge label supplied with the product.

 The filled out label must be adhered in the proximity of the

 product charging port(e.g.onto the inside of the stop value

 cover).

 A contains fluorinated greenhouse gases covered by the

 Kyoto Protocol

 B factory refrigerant charge of the product:see unit name

 plate

 C additional refrigerant amount charged in the field

 D total refrigerant charge

 E outdoor unit

 F refrigerant cylinder and manifold for charging

Air conditioner working temperature: cooling -10~46 degree, heating -15~24 degree.

The single indoor unit will reduce in heating  efficiency if the ambient temperature is under 0 degree.

WARNING

IMPORTANT INFORMATION REGA-

RDING THE REFRIGERANT USED

1

A

B

C

D

kg

kg

kg

R32

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly

qualified persons in order to avoid a hazard.

This appliance is not intended for use by persons (including children) with reduced physical, sensory

or mental capabilities, or lack of experience and knowledge, unless they have been given supervision

or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

This appliance can be used by children aged from 8 years and above and persons with reduced physical,

sensory or mental capabilities or lack of experience and knowledge if they have been given supervision

or instruction concerning use of the appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children

without supervision.

The appliances are not intended to be operated by means of an external timer or separate remote-

control system.

Keep the appliance and its cord out of reach of children less than 8 years.

The A-weighted sound pressure level is below 70 dB.

This appliance is intended to be used by expert or trained users in shops, in light industry and on farms,

or for commercial use by lay persons.

Disconnect the appliance from its power source during maintenance service and when replacing parts.

Содержание 3U55S2PR1FA

Страница 1: ...TIONER 3U55S2PR1FA 4U71S2PR1FA 4U80S2PR1FA 5U125S2PN1FA 0150558811 Move and scrap the air conditioning Contents Safety Precautions Read Before Installation Accessories Procedure for Selecting the location Installation drawings of indoor and outdoor units Precautions on Installation Limitations on the installation Refrigerant piping work Pump Down Operation Wiring work Dred function Test running Tr...

Страница 2: ...y refrigerant charge of the product see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging Air conditioner working temperature cooling 10 46 degree heating 15 24 degree The single indoor unit will reduce in heating efficiency if the ambient temperature is under 0 degree WARNING IMPORTANT IN...

Страница 3: ...ware that refrigerants may not contain an odour The appliance must be installed operated and stored in a room with a floor area larger than the Minimum Room Area specified in the table on the following pages The room should be well ventilated Comply with national gas regulations This appliance can be used by children aged 8 years and above and persons with reduced physical sensory or mental capabi...

Страница 4: ... do not put undue force on the electrical covers or panels Install covers over the wires Incomplete cover installation may cause terminal overheating electrical shock fire or explosion If any refrigerant has leaked out during the installation work ventilate the room The refrigerant produces a toxic gas if exposed to flames may cause explosion After all installation is complete check to make sure t...

Страница 5: ...all be used for maintenance and exposed transporting of refrigerant cylinders and the products to be maintained is not allowed 4 The rain cover or similar shielding material of transporting vehicles shall be provided with certain flame retardancy 5 Leakage warning device of flammable refrigerant shall be installed inside the closed type compartment 6 Anti static device shall be equipped inside the...

Страница 6: ...hecked cannot be less than the area specified on the warning sign of the indoor unit 2 Inspection on the surrounding environment of place of installation the outdoor unit of flammable refrigerants air conditioner cannot be installed inside an enclosed room reserved 3 Power supply switches or other high temperature articles such as the fire source and oil heater shall be avoided below the indoor un...

Страница 7: ...r of the indoor unit is connected to the connector pipe after welding nitrogen more than 4 0MPa shall be charged inside the evaporator and the piping connected to evaporator with a nitrogen cylinder adjusted by a reducing valve Afterwards the valve of the nitrogen cylinder shall be closed for leak detection with soapy water or leak detecting solution The pressure shall be maintained for more than ...

Страница 8: ...with the conical surface of corresponding valve connector The nut of connecting pipes shall be installed at a proper position and then be tightened with a spanner Excessive tightening torque shall be avoided or otherwise the nut may be damaged A digital vacuum gauge shall be connected for vacuumizing The duration of vacuumizing shall be at least 15 minutes and the pressure of the vacuum gauge shal...

Страница 9: ...dging of the refrigeration system requiring no disassembly of refrigeration elements and no welding In case replacement of gas liquid pipes is required during maintenance the joint of evaporator gas liquid pipes of the indoor unit shall be cut off with a cutting knife Connection is only allowed after re flaring the same to the outdoor unit Note in case relocation is required the joint of evaporato...

Страница 10: ...e maintenance site shall be relatively fixed with standardized pipe routing Temporary wires and sockets at the maintenance site are not allowed The environment in which the refrigerant leakage is checked shall be free from potential ignition source Leak detection with halogen probes or any other detector with open fire shall be avoided For the system containing flammable refrigerant leak detection...

Страница 11: ...ied out to ensure no leakage and reliable earthing In case the allowable voltage and current limit may be surpassed during the service of the air conditioner any inductance or capacitance cannot be added in the circuit Only the elements appointed by the air conditioner manufacturer can be used as the parts and components replaced or otherwise a fire or explosion may be triggered in case of refrige...

Страница 12: ...linder and equipment must be evacuated rapidly and all the stop valves on the equipment must be closed 11 Before purification and tests the refrigerant recovered cannot be charged into another refrigeration system Note The air conditioner shall be marked with dates and signature after being scrapped and the refrigerant is discharged It shall be guaranteed that the sign on the air conditioner can r...

Страница 13: ...k without circuit breaker Call the dealer to take measures to prevent the refrigerant from leaking If conditioner is installed in a small room be sure to take every measure in order to prevent suffocation and explosion accident even in case of refrigerant leakage When conditioner is installed or reinstalled the dealer should be responsible for them Incorrect installation may cause water leaking el...

Страница 14: ... If installed improperly dust and or water may enter the unit and present a risk of electric shock smoke fire or explosion Only use refrigerant R32 as indicated on the unit when installing or relocating the unit The use of any other refrigerant or an introduction of air into the unit circuit may cause the unit to run an abnormal cycle and abnormal cycle and cause the unit to burst In the event of ...

Страница 15: ...nections Use liquid refrigerant to charge the system Charge the unit with gas refrigerant will cause the refrigerant in the cylinder to change its composition and will lead to a drop in performance Do not use a charging cylinder The use of charging cylinder will change the composition of the refrigerant and lead to power loss Exercise special care when handling the tools An introduction of foreign...

Страница 16: ...itioners in water Water on the unit presents a risk of electric shock Periodically check the platform on which is placed for damage to prevent the unit from falling If the unit is left on a damaged plarform it may topple over causing injury Things such as nails may be included in the package Dispose of them properly to prevent injury Plastic bags present a choking hazard to children Tear up the pl...

Страница 17: ...rging Meter Refrigerant charging Vacuum Gauze Checking vacuum degree Tools Materials Use Notes Charging Cylinder Refrigerant Charging Must not be used with R32 type units CAUTION Items to Be Checked 1 Verify the type of refrigerant used by the unit to be serviced Refrigerant Type R32 2 Check the symptom exhibited by the unit to be serviced Look in this service handbook for symptoms relating to the...

Страница 18: ...ack into the refrigerant circuit when the vacuum pump power is turned off power failure It is also possible to attach a check valve to the actual vacuum pump afterwards Standard degree of vacuum for the vacuum pump Use a pump which reaches 65Pa or below after 5 minutes of operation In addition be sure to use a vacuum pump that has been properly maintained and oiled using the specified oil If the v...

Страница 19: ...ther places with salty atmosphere of sulfate gas corrosion may shorten the life of the air conditioner 9 Since drain flows out of the outdoor unit do not place under the unit anything which must be kept away from moisture 10 On a flat surface that does not collect rain water 11 Away from strong wind 12 Away from direct exposure to rain or snow 13 Away from sea breeze 14 Away from inflammable mater...

Страница 20: ...nity on the heat exchanger and applying a rust inhibitor more frequently than once a year ODU ODU ODU ODU Sea breeze Sea breeze Sea breeze Sea Sea Sea Protection walls ODU 7 Set the unit on mounting brackets or pad To avoid the adverse effects of snow ice and defrosting issues install the unit on heat pump risers to ensure a sufficient height from the ground In all cases refer to local code for co...

Страница 21: ...pe with the finishing tape from bottom to top Cut thermal insulation pipe to an appropriate length and wrap it with tape making sure that no gap is left in the insulation pipe s cut line more than 10cm more than 10cm more than 60cm more than 25cm 20 Installation figure please refers to the following Do not connected the embedded branch piping and the outdoor unit when only carrying out piping work...

Страница 22: ...g and the maximum allowable height difference between the outdoor and indoor units are listed below The shorter the refrigerant piping the better the performance Connect so that the piping is as short as possible Shortest allowable length per room is 3m 1 Precautions on installation Check the strength and level of the installation ground so that unit will not cause any operating vibration or noise...

Страница 23: ...eight under the outdoor unit s feet 3 In cold areas do not use a drain hose with the outdoor unit Otherwise drain water may freeze impairing heating performance Indoor Unit Outdoor Unit Level difference 15m max Level difference 7 5m max If the outdoor unit is positioned higher than all indoor units Outdoor Unit Indoor Unit Level difference 15m max Level difference 7 5m max If the outdoor unit is p...

Страница 24: ...g all the connection and loosening then retightening thenuts reqeat steps 2 4 Remove covers from liquid stop valve and gas stop valve Turn the liquid stop valve s rod 90 degrees counterclockwise with a hexagonal wrench to open valve Close it after 5 seconds and check for gas leakage Using soapy water check for gas leakage from indoor unit s flare and outdoor unit s flare and valve rods After the c...

Страница 25: ...ecommend 1 Before filling check whether the cylinder has a siphon attached or not It should have something like liquid filling siphon attached displayed on it recommend 2 Be sure to use the R32 tools to ensure pressure and to prevent foreign objects entering 1 This system must use refrigerant R32 2 Add refrigerant 20g per meter when the total piping length exceeds the standard value but make sure ...

Страница 26: ... never install a drier to this R32 unit in order to guarantee its lifetime The drying material may dissolve and damage the system 5 Incompete flaring may cause refrigerant gas leakage Cut exactly at right angles Remove burrs Flare s inner surface must be flaw free The pipe end must be evenly flared in a perfect circle Make sure that the flare nut is fitted Check A Flare tooling die Pipe diameter S...

Страница 27: ...nits for 5U outdoor and the rest outdoors follow the same logic Reinstall the clamp and cover of terminal box according to the Installation Manual after the connection above mentioned done 2 Wiring method Wiring Method for Ring Terminal Block Connect the wire with same diameter to the two sides of the terminal Do not connect the wire with same diameter to the same side Do not connect the wire with...

Страница 28: ...e heat generation Do not connect the power line with different dimensions to the same grounding wire end Improper contact will affect protection Do not connect the power line to the connecting end of communication wire Incorrect connection will cause damage to the connected unit The wiring should ensure that the ground line is the last one to be broken off by force 4 Wiring method of indoor unit 5...

Страница 29: ... bag b Separate DRED module to 3 parts as shown c Continue to separate the DRED module to 7 parts as shown 1 2 3 4 3 2 1 3 a Fix Pin 1 for contractor supplied line through nut 1 seal ring 2 tapered cup nut 3 insert to stud 4 b Repeat step 1 for fixed DRM line c Tighten the screw position on both sides a b c a b c 4 a Tighten the DRED module to right side plate b Tighten the screw Insert the DRED t...

Страница 30: ...r example a flashing means No 15 failure that is indoor and outdoor communication error Wiring Error Check This product is capable of automatic checking of wiring error ON 4 3 2 1 CN2 CN3 CN1 CN4 SW1 4 3 2 1 5 During this operation the digital number will alternately show the compressor working frequency e g 50 stands for the current running frequency and letter CH means checking After this operat...

Страница 31: ...unction of module temp sensor Momentary power failure detection 38 3A 5 8 Malfunction of condensing temp sensor 39 3B 5 9 Malfunction of liquid pipe temp sensor for indoor unit E 40 3C 6 0 System high pressure switch off 42 3E 6 2 System low pressure switch off 43 3F 6 3 44 40 6 4 45 41 6 5 Timer lamp flash time Running lamp flash time Communication failure between Module and ECU Module low or hig...

Страница 32: ...Address Haier Industrial Park Qianwangang Road Eco Tech Development Zone Qingdao 266555 Shandong P R C Contacts TEL 86 532 88936943 FAX 86 532 8893 6999 Website www haier com ...

Отзывы: